{"id":"https://openalex.org/W6944782844","doi":"https://doi.org/10.21227/awav-bn36","title":"Simulated boiler data for fault detection and classification","display_name":"Simulated boiler data for fault detection and classification","publication_year":2019,"publication_date":"2019-03-30","ids":{"openalex":"https://openalex.org/W6944782844","doi":"https://doi.org/10.21227/awav-bn36"},"language":"en","primary_location":{"id":"doi:10.21227/awav-bn36","is_oa":true,"landing_page_url":"https://doi.org/10.21227/awav-bn36","pdf_url":null,"source":{"id":"https://openalex.org/S7407051695","display_name":"IEEE DataPort","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"dataset"},"type":"dataset","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.21227/awav-bn36","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Shohet, R.","orcid":null},"institutions":[{"id":"https://openalex.org/I530967","display_name":"Toronto Metropolitan University","ror":"https://ror.org/05g13zd79","country_code":"CA","type":"education","lineage":["https://openalex.org/I530967"]}],"countries":["CA"],"is_corresponding":true,"raw_author_name":"Shohet, R.","raw_affiliation_strings":["Ryerson University"],"affiliations":[{"raw_affiliation_string":"Ryerson University","institution_ids":["https://openalex.org/I530967"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Kandil, M.","orcid":null},"institutions":[{"id":"https://openalex.org/I530967","display_name":"Toronto Metropolitan University","ror":"https://ror.org/05g13zd79","country_code":"CA","type":"education","lineage":["https://openalex.org/I530967"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Kandil, M.","raw_affiliation_strings":["Ryerson University"],"affiliations":[{"raw_affiliation_string":"Ryerson University","institution_ids":["https://openalex.org/I530967"]}]},{"author_position":"last","author":{"id":null,"display_name":"McArthur, J.J.","orcid":"https://orcid.org/0000-0001-5079-4564"},"institutions":[{"id":"https://openalex.org/I530967","display_name":"Toronto Metropolitan University","ror":"https://ror.org/05g13zd79","country_code":"CA","type":"education","lineage":["https://openalex.org/I530967"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"McArthur, J.J.","raw_affiliation_strings":["Ryerson University"],"affiliations":[{"raw_affiliation_string":"Ryerson University","institution_ids":["https://openalex.org/I530967"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I530967"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":null,"topics":[],"keywords":[{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.717199981212616},{"id":"https://openalex.org/keywords/boiler","display_name":"Boiler (water heating)","score":0.7159000039100647},{"id":"https://openalex.org/keywords/fouling","display_name":"Fouling","score":0.5857999920845032},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5597000122070312},{"id":"https://openalex.org/keywords/combustion","display_name":"Combustion","score":0.48899999260902405},{"id":"https://openalex.org/keywords/mass-flow-rate","display_name":"Mass flow rate","score":0.4163999855518341},{"id":"https://openalex.org/keywords/scaling","display_name":"Scaling","score":0.38179999589920044},{"id":"https://openalex.org/keywords/test-data","display_name":"Test data","score":0.3723999857902527}],"concepts":[{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.717199981212616},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.7159000039100647},{"id":"https://openalex.org/C115792997","wikidata":"https://www.wikidata.org/wiki/Q1439803","display_name":"Fouling","level":3,"score":0.5857999920845032},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5597000122070312},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5324000120162964},{"id":"https://openalex.org/C105923489","wikidata":"https://www.wikidata.org/wiki/Q133235","display_name":"Combustion","level":2,"score":0.48899999260902405},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.4163999855518341},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4101000130176544},{"id":"https://openalex.org/C99844830","wikidata":"https://www.wikidata.org/wiki/Q102441924","display_name":"Scaling","level":2,"score":0.38179999589920044},{"id":"https://openalex.org/C16910744","wikidata":"https://www.wikidata.org/wiki/Q7705759","display_name":"Test data","level":2,"score":0.3723999857902527},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.34459999203681946},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.3370000123977661},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.33309999108314514},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.3222000002861023},{"id":"https://openalex.org/C127145964","wikidata":"https://www.wikidata.org/wiki/Q2142051","display_name":"Heat recovery ventilation","level":3,"score":0.3151000142097473},{"id":"https://openalex.org/C105994980","wikidata":"https://www.wikidata.org/wiki/Q15081379","display_name":"Waste heat recovery unit","level":3,"score":0.313400000333786},{"id":"https://openalex.org/C140779682","wikidata":"https://www.wikidata.org/wiki/Q210868","display_name":"Sampling (signal processing)","level":3,"score":0.30550000071525574},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.2994000017642975},{"id":"https://openalex.org/C155512373","wikidata":"https://www.wikidata.org/wiki/Q287450","display_name":"Residual","level":2,"score":0.29490000009536743},{"id":"https://openalex.org/C151406439","wikidata":"https://www.wikidata.org/wiki/Q186588","display_name":"Time series","level":2,"score":0.2913999855518341},{"id":"https://openalex.org/C33493971","wikidata":"https://www.wikidata.org/wiki/Q3295893","display_name":"Mass flow","level":2,"score":0.29089999198913574},{"id":"https://openalex.org/C118978325","wikidata":"https://www.wikidata.org/wiki/Q4938339","display_name":"Boiler blowdown","level":3,"score":0.28600001335144043},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.26989999413490295},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.2624000012874603}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.21227/awav-bn36","is_oa":true,"landing_page_url":"https://doi.org/10.21227/awav-bn36","pdf_url":null,"source":{"id":"https://openalex.org/S7407051695","display_name":"IEEE DataPort","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"dataset"}],"best_oa_location":{"id":"doi:10.21227/awav-bn36","is_oa":true,"landing_page_url":"https://doi.org/10.21227/awav-bn36","pdf_url":null,"source":{"id":"https://openalex.org/S7407051695","display_name":"IEEE DataPort","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"dataset"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"An":[0],"emulator":[1],"for":[2,76],"the":[3,20,43,53,127,137],"Viessmann":[4],"Vitorond":[5],"200":[6],"Gas":[7],"Fired":[8],"Boiler":[9],"VD2":[10],"Series":[11],"380":[12],"dataset":[13,125],"was":[14,115],"created":[15],"in":[16,63,118],"Matlab/Simulink":[17],"based":[18],"on":[19],"Simscape":[21],"boiler":[22],"model.":[23],"After":[24],"validating":[25],"with":[26,68,72,136],"manufacturer":[27],"test":[28],"data,":[29],"a":[30,77,119,131],"series":[31],"of":[32,42,52,79,121],"faults":[33],"(Excess":[34],"air,":[35],"ranging":[36],"from":[37,46,58,85,95,105],"15%":[38],"-":[39],"50%;":[40],"fouling":[41],"heat":[44,55],"exchanger":[45,56],"1%":[47,59],"to":[48,60,88,98,108,130],"46%;":[49],"and":[50,101,141],"scaling":[51],"water-side":[54],"element":[57],"46%,":[61],"all":[62],"5%":[64],"increments)":[65],"were":[66],"simulated":[67],"this":[69],"emulator,":[70],"along":[71,135],"nominal":[73],"operating":[74],"conditons":[75],"range":[78],"operational":[80],"parameters":[81],"(gas":[82],"fuel":[83],"rate":[84,94],"1":[86],"kg/s":[87,97,100],"4":[89],"kg/s,":[90],"water":[91],"mass":[92],"flow":[93],"3":[96],"12.5":[99],"combustion":[102],"air":[103],"temperature":[104],"283":[106],"K":[107],"303":[109],"K)..":[110],"A":[111],"factorial":[112],"sampling":[113],"method":[114],"used,":[116],"resulting":[117],"total":[120],"27,281":[122],"simulations.":[123],"This":[124],"contains":[126],"points":[128],"visible":[129],"Building":[132],"Automation":[133],"System":[134],"Condition":[138],"(detailed":[139],"class)":[140],"Class":[142],"(fault":[143],"category).":[144]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-11-06T06:51:31.235846","created_date":"2025-10-10T00:00:00"}
