{"id":"https://openalex.org/W6888062803","doi":"https://doi.org/10.18420/inf2022_132","title":"Model-based Integrity Monitoring of Industrial Automation And Control Systems","display_name":"Model-based Integrity Monitoring of Industrial Automation And Control Systems","publication_year":2022,"publication_date":"2022-01-01","ids":{"openalex":"https://openalex.org/W6888062803","doi":"https://doi.org/10.18420/inf2022_132"},"language":"en","primary_location":{"id":"doi:10.18420/inf2022_132","is_oa":true,"landing_page_url":"https://doi.org/10.18420/inf2022_132","pdf_url":null,"source":{"id":"https://openalex.org/S7407052918","display_name":"Gesellschaft f\u00fcr Informatik (GI)","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article-journal"},"type":"article","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.18420/inf2022_132","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Peters, Ludger","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Peters, Ludger","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Khalaf, Mahmoud","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Khalaf, Mahmoud","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Waedt, Karl","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Waedt, Karl","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Schindler, Josef","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Schindler, Josef","raw_affiliation_strings":[],"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Belaidi, Siwar","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Belaidi, Siwar","raw_affiliation_strings":[],"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.24630398,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9689000248908997,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9689000248908997,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.003000000026077032,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10734","display_name":"Information and Cyber Security","score":0.002199999988079071,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/industrial-control-system","display_name":"Industrial control system","score":0.49480000138282776},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.46869999170303345},{"id":"https://openalex.org/keywords/boiler-feedwater","display_name":"Boiler feedwater","score":0.4113999903202057},{"id":"https://openalex.org/keywords/damages","display_name":"Damages","score":0.39800000190734863},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3912000060081482},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.38839998841285706},{"id":"https://openalex.org/keywords/domain","display_name":"Domain (mathematical analysis)","score":0.36039999127388},{"id":"https://openalex.org/keywords/root-cause","display_name":"Root cause","score":0.35199999809265137},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.3467000126838684}],"concepts":[{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.49480000138282776},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48579999804496765},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4733000099658966},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.46869999170303345},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42739999294281006},{"id":"https://openalex.org/C46136384","wikidata":"https://www.wikidata.org/wiki/Q351261","display_name":"Boiler feedwater","level":3,"score":0.4113999903202057},{"id":"https://openalex.org/C2777381055","wikidata":"https://www.wikidata.org/wiki/Q308922","display_name":"Damages","level":2,"score":0.39800000190734863},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3912000060081482},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.38839998841285706},{"id":"https://openalex.org/C36503486","wikidata":"https://www.wikidata.org/wiki/Q11235244","display_name":"Domain (mathematical analysis)","level":2,"score":0.36039999127388},{"id":"https://openalex.org/C84945661","wikidata":"https://www.wikidata.org/wiki/Q7366567","display_name":"Root cause","level":2,"score":0.35199999809265137},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3467000126838684},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3441999852657318},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3409999907016754},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.336899995803833},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.32919999957084656},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.32030001282691956},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.3197000026702881},{"id":"https://openalex.org/C107094494","wikidata":"https://www.wikidata.org/wiki/Q428453","display_name":"Fault tree analysis","level":2,"score":0.3156999945640564},{"id":"https://openalex.org/C739882","wikidata":"https://www.wikidata.org/wiki/Q3560506","display_name":"Anomaly detection","level":2,"score":0.3149000108242035},{"id":"https://openalex.org/C168065819","wikidata":"https://www.wikidata.org/wiki/Q845566","display_name":"Debugging","level":2,"score":0.30300000309944153},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2962000072002411},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.27489998936653137},{"id":"https://openalex.org/C37374048","wikidata":"https://www.wikidata.org/wiki/Q188674","display_name":"Programmable logic controller","level":2,"score":0.2694999873638153},{"id":"https://openalex.org/C2987858997","wikidata":"https://www.wikidata.org/wiki/Q7312160","display_name":"Monitoring and control","level":2,"score":0.2590999901294708},{"id":"https://openalex.org/C2779697362","wikidata":"https://www.wikidata.org/wiki/Q390516","display_name":"Control room","level":2,"score":0.2567000091075897},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.25189998745918274},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.25049999356269836}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.18420/inf2022_132","is_oa":true,"landing_page_url":"https://doi.org/10.18420/inf2022_132","pdf_url":null,"source":{"id":"https://openalex.org/S7407052918","display_name":"Gesellschaft f\u00fcr Informatik (GI)","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article-journal"}],"best_oa_location":{"id":"doi:10.18420/inf2022_132","is_oa":true,"landing_page_url":"https://doi.org/10.18420/inf2022_132","pdf_url":null,"source":{"id":"https://openalex.org/S7407052918","display_name":"Gesellschaft f\u00fcr Informatik (GI)","issn_l":null,"issn":[],"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"article-journal"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1,97],"aims":[2],"to":[3,123,137],"enhance":[4],"cyber":[5],"security":[6],"within":[7],"Electrical":[8],"Power":[9],"Systems":[10],"(EPS)":[11],"of":[12,33,49,93,101,113,126,131],"power":[13],"plants":[14],"by":[15,109],"extending":[16],"and":[17,62,80,87,115,134],"using":[18],"an":[19,34,105],"updated":[20],"plant":[21],"simulator.":[22],"In":[23],"this":[24],"paper,":[25],"we":[26,66],"assume":[27,67],"a":[28,82],"sophisticated":[29],"attacker,":[30],"as":[31],"part":[32],"Advanced":[35],"Persistent":[36],"Threat":[37],"(APT),":[38],"who":[39],"gradually":[40,110],"damages":[41],"or":[42,119],"manipulates":[43],"primary":[44],"assets":[45],"(in":[46],"the":[47,69,76,124,127],"sense":[48],"ISO/IEC":[50],"27005:2018,":[51],"e.":[52],"g.":[53],"main":[54],"cooling":[55],"water":[56],"pumps,":[57,59],"feedwater":[58],"safety":[60],"valves,":[61],"circuit":[63],"breakers).":[64],"Accordingly,":[65],"that":[68],"attack":[70],"agent":[71],"performs":[72],"gradual":[73],"manipulations":[74],"at":[75],"application":[77],"level.":[78],"Detecting":[79],"predicting":[81],"potential":[83],"anomaly":[84],"is":[85],"designed":[86],"implemented":[88],"based":[89],"on":[90],"machine":[91],"learning":[92],"expected":[94],"behavior.":[95],"The":[96],"will":[98,141],"include":[99],"examples":[100],"attacks":[102],"executed":[103],"over":[104],"extended":[106],"time":[107],"period":[108],"manipulating":[111],"combinations":[112],"analog":[114],"binary":[116],"signal":[117],"values":[118],"set-points.":[120],"Challenges":[121],"related":[122],"training":[125],"detection":[128],"algorithms,":[129],"avoidance":[130],"false":[132],"positives,":[133],"concise":[135],"reporting":[136],"non-security":[138],"domain":[139],"experts":[140],"also":[142],"be":[143],"addressed.":[144]},"counts_by_year":[],"updated_date":"2025-11-06T06:51:31.235846","created_date":"2025-10-10T00:00:00"}
