{"id":"https://openalex.org/W2075688903","doi":"https://doi.org/10.1631/jzus.c1300171","title":"Design and analysis of an underwater inductive coupling power transfer system for autonomous underwater vehicle docking applications","display_name":"Design and analysis of an underwater inductive coupling power transfer system for autonomous underwater vehicle docking applications","publication_year":2014,"publication_date":"2014-01-01","ids":{"openalex":"https://openalex.org/W2075688903","doi":"https://doi.org/10.1631/jzus.c1300171","mag":"2075688903"},"language":"en","primary_location":{"id":"doi:10.1631/jzus.c1300171","is_oa":false,"landing_page_url":"https://doi.org/10.1631/jzus.c1300171","pdf_url":null,"source":{"id":"https://openalex.org/S199067057","display_name":"Frontiers of Information Technology & Electronic Engineering","issn_l":"1869-1951","issn":["1869-1951","1869-196X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310311937","host_organization_name":"Zhejiang University Press","host_organization_lineage":["https://openalex.org/P4310311937"],"host_organization_lineage_names":["Zhejiang University Press"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Zhejiang University SCIENCE C","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040770775","display_name":"Jianguang Shi","orcid":"https://orcid.org/0000-0003-4148-6388"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jian-guang Shi","raw_affiliation_strings":["State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","State Key Laboratory of Fluid Power Transmission and Control"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","institution_ids":[]},{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101706829","display_name":"Dejun Li","orcid":"https://orcid.org/0000-0002-1735-3713"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"De-jun Li","raw_affiliation_strings":["State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","State Key Laboratory of Fluid Power Transmission and Control"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","institution_ids":[]},{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control","institution_ids":[]}]},{"author_position":"last","author":{"id":null,"display_name":"Can-jun Yang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Can-jun Yang","raw_affiliation_strings":["State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","State Key Laboratory of Fluid Power Transmission and Control"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control, Hangzhou, 310027, China","institution_ids":[]},{"raw_affiliation_string":"State Key Laboratory of Fluid Power Transmission and Control","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5101706829"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.3097,"has_fulltext":false,"cited_by_count":93,"citation_normalized_percentile":{"value":0.92734328,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"15","issue":"1","first_page":"51","last_page":"62"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11392","display_name":"Energy Harvesting in Wireless Networks","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11230","display_name":"Innovative Energy Harvesting Technologies","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/maximum-power-transfer-theorem","display_name":"Maximum power transfer theorem","score":0.831054151058197},{"id":"https://openalex.org/keywords/underwater","display_name":"Underwater","score":0.7021907567977905},{"id":"https://openalex.org/keywords/wireless-power-transfer","display_name":"Wireless power transfer","score":0.6584880352020264},{"id":"https://openalex.org/keywords/power-transmission","display_name":"Power transmission","score":0.6484850645065308},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6097055077552795},{"id":"https://openalex.org/keywords/inductive-coupling","display_name":"Inductive coupling","score":0.5332595705986023},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4991450309753418},{"id":"https://openalex.org/keywords/finite-element-method","display_name":"Finite element method","score":0.486331045627594},{"id":"https://openalex.org/keywords/coupling","display_name":"Coupling (piping)","score":0.44691169261932373},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.44224998354911804},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.38185441493988037},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3615630865097046},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3245248794555664},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.185715913772583},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.1416167914867401},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.13397720456123352},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.10191488265991211}],"concepts":[{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.831054151058197},{"id":"https://openalex.org/C98083399","wikidata":"https://www.wikidata.org/wiki/Q3246517","display_name":"Underwater","level":2,"score":0.7021907567977905},{"id":"https://openalex.org/C2779423816","wikidata":"https://www.wikidata.org/wiki/Q6856398","display_name":"Wireless power transfer","level":3,"score":0.6584880352020264},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.6484850645065308},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6097055077552795},{"id":"https://openalex.org/C177872590","wikidata":"https://www.wikidata.org/wiki/Q1498289","display_name":"Inductive coupling","level":2,"score":0.5332595705986023},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4991450309753418},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.486331045627594},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.44691169261932373},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.44224998354911804},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.38185441493988037},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3615630865097046},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3245248794555664},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.185715913772583},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1416167914867401},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.13397720456123352},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.10191488265991211},{"id":"https://openalex.org/C111368507","wikidata":"https://www.wikidata.org/wiki/Q43518","display_name":"Oceanography","level":1,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1631/jzus.c1300171","is_oa":false,"landing_page_url":"https://doi.org/10.1631/jzus.c1300171","pdf_url":null,"source":{"id":"https://openalex.org/S199067057","display_name":"Frontiers of Information Technology & Electronic Engineering","issn_l":"1869-1951","issn":["1869-1951","1869-196X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310311937","host_organization_name":"Zhejiang University Press","host_organization_lineage":["https://openalex.org/P4310311937"],"host_organization_lineage_names":["Zhejiang University Press"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Zhejiang University SCIENCE C","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.47999998927116394,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1513980003","https://openalex.org/W1972436942","https://openalex.org/W2026834139","https://openalex.org/W2031980744","https://openalex.org/W2036539382","https://openalex.org/W2047274780","https://openalex.org/W2050084539","https://openalex.org/W2065363397","https://openalex.org/W2078780443","https://openalex.org/W2097036926","https://openalex.org/W2099304692","https://openalex.org/W2100788482","https://openalex.org/W2101445338","https://openalex.org/W2102689363","https://openalex.org/W2131561725","https://openalex.org/W2136256029","https://openalex.org/W2140012140","https://openalex.org/W2145978612","https://openalex.org/W2150407442","https://openalex.org/W2150830913","https://openalex.org/W2156447533","https://openalex.org/W2162751955","https://openalex.org/W2165664422"],"related_works":["https://openalex.org/W4205317126","https://openalex.org/W2763444231","https://openalex.org/W2236924022","https://openalex.org/W2996994402","https://openalex.org/W2740114034","https://openalex.org/W4327640760","https://openalex.org/W2928000672","https://openalex.org/W2092499589","https://openalex.org/W2928658690","https://openalex.org/W2630515914"],"abstract_inverted_index":{"We":[0],"develop":[1],"a":[2,44],"new":[3,191],"kind":[4],"of":[5,30,58,79,90,103,110,181],"underwater":[6,20],"inductive":[7],"coupling":[8],"power":[9,16,56,81,109,138,149],"transfer":[10,17],"(ICPT)":[11],"system":[12,32,113],"to":[13,53,86,116,124,157],"evaluate":[14],"wireless":[15],"in":[18,64,68,74,177,189],"autonomous":[19],"vehicle":[21],"(AUV)":[22],"docking":[23],"applications.":[24],"Parameters":[25],"that":[26,130],"determine":[27],"the":[28,31,55,59,80,88,104,111,120,131,136,143,147,153,179],"performance":[29,180],"are":[33,51,98],"systematically":[34],"analyzed":[35],"through":[36],"mathematical":[37],"methods.":[38],"A":[39],"circuit":[40],"simulation":[41,49,96],"model":[42,50],"and":[43,70,95,119,170,185],"finite":[45],"element":[46],"analysis":[47,173],"(FEA)":[48],"developed":[52],"study":[54],"losses":[57,82],"system,":[60],"including":[61],"copper":[62],"loss":[63,67,73],"coils,":[65],"semiconductor":[66],"circuits,":[69],"eddy":[71],"current":[72],"transmission":[75,137],"media.":[76],"The":[77,107,126,160,172],"characteristics":[78],"can":[83,162],"provide":[84],"guidelines":[85],"improve":[87],"efficiency":[89,121,132,154,161],"ICPT":[91,183],"systems.":[92,192],"Calculation":[93],"results":[94,97,128],"validated":[99],"by":[100,141,166],"relevant":[101],"experiments":[102],"prototype":[105,112],"system.":[106],"output":[108,148],"is":[114,122,139,155],"up":[115,123],"45":[117],"W":[118],"0.84.":[125],"preliminary":[127],"indicate":[129],"will":[133],"increase":[134],"as":[135],"raised":[140],"increasing":[142],"input":[144],"voltage.":[145],"When":[146],"reaches":[150],"500":[151],"W,":[152],"expected":[156],"exceed":[158],"0.94.":[159],"be":[163,187],"further":[164],"improved":[165],"choosing":[167],"proper":[168],"semiconductors":[169],"coils.":[171],"methods":[174],"prove":[175],"effective":[176],"predicting":[178],"similar":[182],"systems":[184],"should":[186],"useful":[188],"designing":[190]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":12},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":9},{"year":2019,"cited_by_count":8},{"year":2018,"cited_by_count":12},{"year":2017,"cited_by_count":8},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":4},{"year":2014,"cited_by_count":1}],"updated_date":"2026-07-31T08:31:51.225901","created_date":"2025-10-10T00:00:00"}
