{"id":"https://openalex.org/W2083807160","doi":"https://doi.org/10.1587/elex.10.20130011","title":"A fast transient response shunt low dropout regulator","display_name":"A fast transient response shunt low dropout regulator","publication_year":2013,"publication_date":"2013-01-01","ids":{"openalex":"https://openalex.org/W2083807160","doi":"https://doi.org/10.1587/elex.10.20130011","mag":"2083807160"},"language":"en","primary_location":{"id":"doi:10.1587/elex.10.20130011","is_oa":true,"landing_page_url":"https://doi.org/10.1587/elex.10.20130011","pdf_url":"https://www.jstage.jst.go.jp/article/elex/10/3/10_10.20130011/_pdf","source":{"id":"https://openalex.org/S207433681","display_name":"IEICE Electronics Express","issn_l":"1349-2543","issn":["1349-2543","1349-9467"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4320800604","host_organization_name":"Institute of Electronics, Information and Communication Engineers","host_organization_lineage":["https://openalex.org/P4320800604"],"host_organization_lineage_names":["Institute of Electronics, Information and Communication Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEICE Electronics Express","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.jstage.jst.go.jp/article/elex/10/3/10_10.20130011/_pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101803760","display_name":"Won-Seok Oh","orcid":null},"institutions":[{"id":"https://openalex.org/I1311921367","display_name":"Advanced Micro Devices (Canada)","ror":"https://ror.org/02yh0k313","country_code":"CA","type":"company","lineage":["https://openalex.org/I1311921367","https://openalex.org/I4210137977"]},{"id":"https://openalex.org/I4210106739","display_name":"MicroLink Devices (United States)","ror":"https://ror.org/01dpfst30","country_code":"US","type":"company","lineage":["https://openalex.org/I4210106739"]},{"id":"https://openalex.org/I4210137977","display_name":"Advanced Micro Devices (United States)","ror":"https://ror.org/04kd6c783","country_code":"US","type":"company","lineage":["https://openalex.org/I4210137977"]}],"countries":["CA","US"],"is_corresponding":false,"raw_author_name":"Wonseok Oh","raw_affiliation_strings":["RF Micro Devices, Inc"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RF Micro Devices, Inc","institution_ids":["https://openalex.org/I4210137977","https://openalex.org/I1311921367","https://openalex.org/I4210106739"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100737778","display_name":"Hyun\u2010Tae Kim","orcid":"https://orcid.org/0000-0002-4385-0406"},"institutions":[{"id":"https://openalex.org/I1311921367","display_name":"Advanced Micro Devices (Canada)","ror":"https://ror.org/02yh0k313","country_code":"CA","type":"company","lineage":["https://openalex.org/I1311921367","https://openalex.org/I4210137977"]},{"id":"https://openalex.org/I4210106739","display_name":"MicroLink Devices (United States)","ror":"https://ror.org/01dpfst30","country_code":"US","type":"company","lineage":["https://openalex.org/I4210106739"]},{"id":"https://openalex.org/I4210137977","display_name":"Advanced Micro Devices (United States)","ror":"https://ror.org/04kd6c783","country_code":"US","type":"company","lineage":["https://openalex.org/I4210137977"]}],"countries":["CA","US"],"is_corresponding":false,"raw_author_name":"Hyuntae Kim","raw_affiliation_strings":["RF Micro Devices, Inc"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RF Micro Devices, Inc","institution_ids":["https://openalex.org/I4210137977","https://openalex.org/I1311921367","https://openalex.org/I4210106739"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089016705","display_name":"Praveen Nadimpalli","orcid":null},"institutions":[{"id":"https://openalex.org/I1311921367","display_name":"Advanced Micro Devices (Canada)","ror":"https://ror.org/02yh0k313","country_code":"CA","type":"company","lineage":["https://openalex.org/I1311921367","https://openalex.org/I4210137977"]},{"id":"https://openalex.org/I4210106739","display_name":"MicroLink Devices (United States)","ror":"https://ror.org/01dpfst30","country_code":"US","type":"company","lineage":["https://openalex.org/I4210106739"]},{"id":"https://openalex.org/I4210137977","display_name":"Advanced Micro Devices (United States)","ror":"https://ror.org/04kd6c783","country_code":"US","type":"company","lineage":["https://openalex.org/I4210137977"]}],"countries":["CA","US"],"is_corresponding":false,"raw_author_name":"Praveen Nadimpalli","raw_affiliation_strings":["RF Micro Devices, Inc"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"RF Micro Devices, Inc","institution_ids":["https://openalex.org/I4210137977","https://openalex.org/I1311921367","https://openalex.org/I4210106739"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.13372654,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"10","issue":"3","first_page":"20130011","last_page":"20130011"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10187","display_name":"Radio Frequency Integrated Circuit Design","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11417","display_name":"Advancements in PLL and VCO Technologies","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/regulator","display_name":"Regulator","score":0.9150846600532532},{"id":"https://openalex.org/keywords/low-dropout-regulator","display_name":"Low-dropout regulator","score":0.8934266567230225},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.7678767442703247},{"id":"https://openalex.org/keywords/shunt","display_name":"Shunt (medical)","score":0.7561771869659424},{"id":"https://openalex.org/keywords/dropout-voltage","display_name":"Dropout voltage","score":0.6669195294380188},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6192131638526917},{"id":"https://openalex.org/keywords/transient-response","display_name":"Transient response","score":0.5314235687255859},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4867803752422333},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.4451095163822174},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4306303858757019},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.2936817407608032},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.16499152779579163},{"id":"https://openalex.org/keywords/biology","display_name":"Biology","score":0.12539950013160706},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.0996355414390564},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.0735616385936737}],"concepts":[{"id":"https://openalex.org/C6929976","wikidata":"https://www.wikidata.org/wiki/Q3771881","display_name":"Regulator","level":3,"score":0.9150846600532532},{"id":"https://openalex.org/C140501009","wikidata":"https://www.wikidata.org/wiki/Q6692746","display_name":"Low-dropout regulator","level":5,"score":0.8934266567230225},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.7678767442703247},{"id":"https://openalex.org/C2780968331","wikidata":"https://www.wikidata.org/wiki/Q1890115","display_name":"Shunt (medical)","level":2,"score":0.7561771869659424},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.6669195294380188},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6192131638526917},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.5314235687255859},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4867803752422333},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.4451095163822174},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4306303858757019},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2936817407608032},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.16499152779579163},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.12539950013160706},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0996355414390564},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0735616385936737},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1587/elex.10.20130011","is_oa":true,"landing_page_url":"https://doi.org/10.1587/elex.10.20130011","pdf_url":"https://www.jstage.jst.go.jp/article/elex/10/3/10_10.20130011/_pdf","source":{"id":"https://openalex.org/S207433681","display_name":"IEICE Electronics Express","issn_l":"1349-2543","issn":["1349-2543","1349-9467"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4320800604","host_organization_name":"Institute of Electronics, Information and Communication Engineers","host_organization_lineage":["https://openalex.org/P4320800604"],"host_organization_lineage_names":["Institute of Electronics, Information and Communication Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEICE Electronics Express","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1587/elex.10.20130011","is_oa":true,"landing_page_url":"https://doi.org/10.1587/elex.10.20130011","pdf_url":"https://www.jstage.jst.go.jp/article/elex/10/3/10_10.20130011/_pdf","source":{"id":"https://openalex.org/S207433681","display_name":"IEICE Electronics Express","issn_l":"1349-2543","issn":["1349-2543","1349-9467"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4320800604","host_organization_name":"Institute of Electronics, Information and Communication Engineers","host_organization_lineage":["https://openalex.org/P4320800604"],"host_organization_lineage_names":["Institute of Electronics, Information and Communication Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEICE Electronics Express","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.8600000143051147,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2083807160.pdf","grobid_xml":"https://content.openalex.org/works/W2083807160.grobid-xml"},"referenced_works_count":4,"referenced_works":["https://openalex.org/W2034720635","https://openalex.org/W2041477163","https://openalex.org/W2127720354","https://openalex.org/W2161857259"],"related_works":["https://openalex.org/W1982997428","https://openalex.org/W2044172536","https://openalex.org/W2371498377","https://openalex.org/W2370995213","https://openalex.org/W3185987145","https://openalex.org/W4366165321","https://openalex.org/W3081405802","https://openalex.org/W4287514677","https://openalex.org/W2017190659","https://openalex.org/W2737475872"],"abstract_inverted_index":{"In":[0,36],"this":[1,37],"paper,":[2,38],"the":[3,15,30,48,87],"proposed":[4,45,60,88],"shunt":[5,16,41,53,61,89],"regulator":[6,18,42,54,62,90],"is":[7,44,65,75],"presented.":[8],"Compared":[9],"with":[10,55],"a":[11,39,52],"series":[12,82],"voltage":[13,17],"regulator,":[14],"gives":[19],"wideband":[20],"power":[21],"supply":[22],"rejection":[23],"(PSR)":[24],"and":[25,73],"fast":[26],"transient":[27,63],"response":[28,64],"at":[29,76],"expense":[31],"of":[32,51,86],"large":[33],"quiescent":[34,57],"current.":[35,58],"novel":[40],"architecture":[43],"to":[46,94],"achieve":[47],"genuine":[49],"characteristic":[50,85],"small":[56],"The":[59],"3.98\u00b5sec":[66],"over":[67],"full":[68],"load":[69],"current":[70],"rising":[71],"step":[72],"it":[74],"least":[77],"3.5":[78],"times":[79],"faster":[80],"than":[81],"regulator.":[83],"PSR":[84],"shows":[91],"-22.4dB":[92],"up":[93],"200kHz.":[95]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
