{"id":"https://openalex.org/W4389004452","doi":"https://doi.org/10.1515/auto-2023-0128","title":"DC voltage ancillary controller for dynamic security of shunt-compensated microgrids","display_name":"DC voltage ancillary controller for dynamic security of shunt-compensated microgrids","publication_year":2023,"publication_date":"2023-11-25","ids":{"openalex":"https://openalex.org/W4389004452","doi":"https://doi.org/10.1515/auto-2023-0128"},"language":"en","primary_location":{"id":"doi:10.1515/auto-2023-0128","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1515/auto-2023-0128","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079122859","display_name":"Gabriel Cocco","orcid":"https://orcid.org/0000-0002-2650-6443"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":true,"raw_author_name":"Gabriel Maier Cocco","raw_affiliation_strings":["Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015750778","display_name":"F.E. Bisogno","orcid":"https://orcid.org/0000-0002-2006-3899"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"F\u00e1bio Ecke Bisogno","raw_affiliation_strings":["Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5064289150","display_name":"Robinson Figueiredo de Camargo","orcid":"https://orcid.org/0000-0001-5858-1635"},"institutions":[{"id":"https://openalex.org/I33501960","display_name":"Universidade Federal de Santa Maria","ror":"https://ror.org/01b78mz79","country_code":"BR","type":"education","lineage":["https://openalex.org/I33501960"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Robinson Figueiredo de Camargo","raw_affiliation_strings":["Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Federal University of Santa Maria (UFSM), Power Electronics and Control Research Group (GEPOC) , Santa Maria , Brazil","institution_ids":["https://openalex.org/I33501960"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043231773","display_name":"Eric Glende","orcid":"https://orcid.org/0009-0002-7678-9215"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Eric Glende","raw_affiliation_strings":["Otto von Guericke University (OVGU), Institute of Electric Power Systems (IESY) , Magdeburg , Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Otto von Guericke University (OVGU), Institute of Electric Power Systems (IESY) , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042758411","display_name":"Martin Wolter","orcid":"https://orcid.org/0000-0003-0281-0501"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Wolter","raw_affiliation_strings":["Otto von Guericke University (OVGU), Institute of Electric Power Systems (IESY) , Magdeburg , Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Otto von Guericke University (OVGU), Institute of Electric Power Systems (IESY) , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5079122859"],"corresponding_institution_ids":["https://openalex.org/I33501960"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.18480819,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"71","issue":"12","first_page":"1040","last_page":"1050"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9987999796867371,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.6400083303451538},{"id":"https://openalex.org/keywords/robustness","display_name":"Robustness (evolution)","score":0.560787558555603},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5305997133255005},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4733835756778717},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.46895331144332886},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4638649821281433},{"id":"https://openalex.org/keywords/voltage-controller","display_name":"Voltage controller","score":0.4529310166835785},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4525647461414337},{"id":"https://openalex.org/keywords/shunt","display_name":"Shunt (medical)","score":0.44921875},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.43008798360824585},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.41735172271728516},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.417336642742157},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3558424711227417},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.23640140891075134},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.21936267614364624},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14901965856552124},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.10487577319145203},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.09609070420265198},{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.07300597429275513}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6400083303451538},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.560787558555603},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5305997133255005},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4733835756778717},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.46895331144332886},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4638649821281433},{"id":"https://openalex.org/C156120966","wikidata":"https://www.wikidata.org/wiki/Q7940742","display_name":"Voltage controller","level":5,"score":0.4529310166835785},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4525647461414337},{"id":"https://openalex.org/C2780968331","wikidata":"https://www.wikidata.org/wiki/Q1890115","display_name":"Shunt (medical)","level":2,"score":0.44921875},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.43008798360824585},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.41735172271728516},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.417336642742157},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3558424711227417},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.23640140891075134},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.21936267614364624},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14901965856552124},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.10487577319145203},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.09609070420265198},{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.07300597429275513},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1515/auto-2023-0128","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1515/auto-2023-0128","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8799999952316284,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G3791004696","display_name":null,"funder_award_id":"17/2551- 0000517-1","funder_id":"https://openalex.org/F4320322502","funder_display_name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado do Rio Grande do Sul"},{"id":"https://openalex.org/G5532488418","display_name":null,"funder_award_id":"23038.000776/2017-54","funder_id":"https://openalex.org/F4320321091","funder_display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior"},{"id":"https://openalex.org/G8487780864","display_name":null,"funder_award_id":"465640/2014-1","funder_id":"https://openalex.org/F4320322025","funder_display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico"}],"funders":[{"id":"https://openalex.org/F4320321091","display_name":"Coordena\u00e7\u00e3o de Aperfei\u00e7oamento de Pessoal de N\u00edvel Superior","ror":"https://ror.org/00x0ma614"},{"id":"https://openalex.org/F4320322025","display_name":"Conselho Nacional de Desenvolvimento Cient\u00edfico e Tecnol\u00f3gico","ror":"https://ror.org/03swz6y49"},{"id":"https://openalex.org/F4320322502","display_name":"Funda\u00e7\u00e3o de Amparo \u00e0 Pesquisa do Estado do Rio Grande do Sul","ror":"https://ror.org/05k49za97"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W1982588147","https://openalex.org/W1985029831","https://openalex.org/W2082226269","https://openalex.org/W2085969679","https://openalex.org/W2103687379","https://openalex.org/W2126580932","https://openalex.org/W2138876052","https://openalex.org/W2149401199","https://openalex.org/W2151389342","https://openalex.org/W2223849949","https://openalex.org/W2235087177","https://openalex.org/W2540693253","https://openalex.org/W2582078605","https://openalex.org/W2755887995","https://openalex.org/W2769781563","https://openalex.org/W2920556581","https://openalex.org/W3099133988","https://openalex.org/W3120361591","https://openalex.org/W4205775844","https://openalex.org/W4220874845","https://openalex.org/W4224307185","https://openalex.org/W4285196930","https://openalex.org/W4298363721","https://openalex.org/W4307304537","https://openalex.org/W4309234647","https://openalex.org/W4310174138","https://openalex.org/W4311778553","https://openalex.org/W4311925375","https://openalex.org/W4318822244","https://openalex.org/W4324291204","https://openalex.org/W4384305384"],"related_works":["https://openalex.org/W2323778284","https://openalex.org/W4312311708","https://openalex.org/W116508656","https://openalex.org/W2410191826","https://openalex.org/W803323728","https://openalex.org/W4308389072","https://openalex.org/W1987689185","https://openalex.org/W2006004274","https://openalex.org/W3082229950","https://openalex.org/W2893865120"],"abstract_inverted_index":{"Abstract":[0],"Modern":[1],"power":[2,16],"systems":[3,55],"require":[4],"special":[5],"features":[6],"from":[7],"the":[8,15,74],"distributed":[9,80],"energy":[10],"resources":[11],"especially":[12],"to":[13,102,132],"meet":[14],"quality":[17],"and":[18,62,125,136],"dynamic":[19],"security.":[20],"The":[21,86,111],"distribution":[22],"static":[23],"synchronous":[24],"compensator":[25,137],"(DSTATCOM)":[26],"has":[27],"a":[28,43,47,71,90],"safe":[29],"DC":[30,97],"voltage":[31,100],"operating":[32],"range":[33,101],"that":[34,93],"is":[35,46,117],"often":[36],"unexplored.":[37],"Self-excited":[38],"induction":[39],"generators":[40],"(SEIGs)":[41],"with":[42,108],"shunt":[44,75],"DSTATCOM":[45],"well-known":[48],"solution":[49],"for":[50,114,122],"low-power,":[51],"low-cost":[52],"generation.":[53],"These":[54],"may":[56],"have":[57],"poor":[58],"robustness":[59],"against":[60],"surges":[61],"contingencies.":[63],"This":[64],"paper":[65],"proposes":[66],"an":[67,78,95],"ancillary":[68],"controller":[69,87],"as":[70,119,121],"supplement":[72],"in":[73],"compensation":[76],"of":[77,89],"off-grid":[79],"generation":[81,126],"system":[82,134],"powered":[83],"by":[84],"SEIGs.":[85],"consists":[88],"variable":[91],"structure":[92],"uses":[94],"adequate":[96],"bus":[98],"capacitor":[99],"provide":[103],"fast":[104],"frequency":[105],"response":[106],"(FFR)":[107],"soft":[109],"recovery.":[110],"control":[112],"performance":[113],"fault":[115],"rejection":[116],"evaluated":[118],"well":[120],"load":[123],"disturbances":[124],"contingency.":[127],"Simulation":[128],"results":[129],"are":[130],"presented":[131],"demonstrate":[133],"operation":[135],"performance.":[138]},"counts_by_year":[],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
