{"id":"https://openalex.org/W4416581398","doi":"https://doi.org/10.1515/jisys-2024-0348","title":"Power line fault detection based on waveform comparison offline location technology","display_name":"Power line fault detection based on waveform comparison offline location technology","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4416581398","doi":"https://doi.org/10.1515/jisys-2024-0348"},"language":"en","primary_location":{"id":"doi:10.1515/jisys-2024-0348","is_oa":true,"landing_page_url":"https://doi.org/10.1515/jisys-2024-0348","pdf_url":"https://www.degruyterbrill.com/document/doi/10.1515/jisys-2024-0348/pdf","source":{"id":"https://openalex.org/S2764846071","display_name":"Journal of Intelligent Systems","issn_l":"0334-1860","issn":["0334-1860","2191-026X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310315148","host_organization_name":"IlmuKomputer.Com","host_organization_lineage":["https://openalex.org/P4310315148"],"host_organization_lineage_names":["IlmuKomputer.Com"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent Systems","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.degruyterbrill.com/document/doi/10.1515/jisys-2024-0348/pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017342276","display_name":"Shengzhu Li","orcid":"https://orcid.org/0009-0009-8776-0099"},"institutions":[{"id":"https://openalex.org/I4210138151","display_name":"Jilin Electric Power Research Institute (China)","ror":"https://ror.org/03pw0zs24","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210138151"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Shengzhu Li","raw_affiliation_strings":["State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China","institution_ids":["https://openalex.org/I4210138151"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102557365","display_name":"Yulin Ge","orcid":"https://orcid.org/0000-0003-1166-2643"},"institutions":[{"id":"https://openalex.org/I4210138151","display_name":"Jilin Electric Power Research Institute (China)","ror":"https://ror.org/03pw0zs24","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210138151"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yulin Ge","raw_affiliation_strings":["State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China","institution_ids":["https://openalex.org/I4210138151"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100424175","display_name":"Zhipeng Wang","orcid":"https://orcid.org/0000-0003-3039-7582"},"institutions":[{"id":"https://openalex.org/I4210138151","display_name":"Jilin Electric Power Research Institute (China)","ror":"https://ror.org/03pw0zs24","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210138151"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhipeng Wang","raw_affiliation_strings":["State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China","institution_ids":["https://openalex.org/I4210138151"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5004231774","display_name":"Zejian Yun","orcid":null},"institutions":[{"id":"https://openalex.org/I4210138151","display_name":"Jilin Electric Power Research Institute (China)","ror":"https://ror.org/03pw0zs24","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210138151"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zejian Yun","raw_affiliation_strings":["State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Changchun Power Supply Company , Changchun , Jilin, 130021 , China","institution_ids":["https://openalex.org/I4210138151"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5002283922","display_name":"Jianze Liu","orcid":"https://orcid.org/0000-0003-4621-9043"},"institutions":[{"id":"https://openalex.org/I4210155967","display_name":"OriginWater (China)","ror":"https://ror.org/04h7gmn81","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210155967"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jianze Liu","raw_affiliation_strings":["Beijing Dan Hua Hao Bo Power Science and Technology Co., Ltd , Beijing , 100085 , China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Beijing Dan Hua Hao Bo Power Science and Technology Co., Ltd , Beijing , 100085 , China","institution_ids":["https://openalex.org/I4210155967"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5017342276"],"corresponding_institution_ids":["https://openalex.org/I4210138151"],"apc_list":{"value":1000,"currency":"EUR","value_usd":1078},"apc_paid":{"value":1000,"currency":"EUR","value_usd":1078},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.41819166,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"34","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.6980999708175659,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.6980999708175659,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.05849999934434891,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.0272000003606081,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/waveform","display_name":"Waveform","score":0.7924000024795532},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6000000238418579},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5514000058174133},{"id":"https://openalex.org/keywords/false-alarm","display_name":"False alarm","score":0.4921000003814697},{"id":"https://openalex.org/keywords/similarity","display_name":"Similarity (geometry)","score":0.47600001096725464},{"id":"https://openalex.org/keywords/constant-false-alarm-rate","display_name":"Constant false alarm rate","score":0.4726000130176544},{"id":"https://openalex.org/keywords/correlation-coefficient","display_name":"Correlation coefficient","score":0.47189998626708984},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.461899995803833}],"concepts":[{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.7924000024795532},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6000000238418579},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.592199981212616},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5514000058174133},{"id":"https://openalex.org/C2776836416","wikidata":"https://www.wikidata.org/wiki/Q1364844","display_name":"False alarm","level":2,"score":0.4921000003814697},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.47690001130104065},{"id":"https://openalex.org/C103278499","wikidata":"https://www.wikidata.org/wiki/Q254465","display_name":"Similarity (geometry)","level":3,"score":0.47600001096725464},{"id":"https://openalex.org/C77052588","wikidata":"https://www.wikidata.org/wiki/Q644307","display_name":"Constant false alarm rate","level":2,"score":0.4726000130176544},{"id":"https://openalex.org/C2780092901","wikidata":"https://www.wikidata.org/wiki/Q3433612","display_name":"Correlation coefficient","level":2,"score":0.47189998626708984},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.461899995803833},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4307999908924103},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.42980000376701355},{"id":"https://openalex.org/C2776401178","wikidata":"https://www.wikidata.org/wiki/Q12050496","display_name":"Feature (linguistics)","level":2,"score":0.3982999920845032},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.3792000114917755},{"id":"https://openalex.org/C52622490","wikidata":"https://www.wikidata.org/wiki/Q1026626","display_name":"Feature extraction","level":2,"score":0.3513999879360199},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.33160001039505005},{"id":"https://openalex.org/C31712484","wikidata":"https://www.wikidata.org/wiki/Q618740","display_name":"Recloser","level":3,"score":0.31540000438690186},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.29980000853538513},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2809000015258789},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.2791999876499176},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.2741999924182892},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.25690001249313354}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1515/jisys-2024-0348","is_oa":true,"landing_page_url":"https://doi.org/10.1515/jisys-2024-0348","pdf_url":"https://www.degruyterbrill.com/document/doi/10.1515/jisys-2024-0348/pdf","source":{"id":"https://openalex.org/S2764846071","display_name":"Journal of Intelligent Systems","issn_l":"0334-1860","issn":["0334-1860","2191-026X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310315148","host_organization_name":"IlmuKomputer.Com","host_organization_lineage":["https://openalex.org/P4310315148"],"host_organization_lineage_names":["IlmuKomputer.Com"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent Systems","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:02b835214e2947208bf41fe8ceea5791","is_oa":true,"landing_page_url":"https://doaj.org/article/02b835214e2947208bf41fe8ceea5791","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Journal of Intelligent Systems, Vol 34, Iss 1, Pp 161-4 (2025)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1515/jisys-2024-0348","is_oa":true,"landing_page_url":"https://doi.org/10.1515/jisys-2024-0348","pdf_url":"https://www.degruyterbrill.com/document/doi/10.1515/jisys-2024-0348/pdf","source":{"id":"https://openalex.org/S2764846071","display_name":"Journal of Intelligent Systems","issn_l":"0334-1860","issn":["0334-1860","2191-026X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310315148","host_organization_name":"IlmuKomputer.Com","host_organization_lineage":["https://openalex.org/P4310315148"],"host_organization_lineage_names":["IlmuKomputer.Com"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Intelligent Systems","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4416581398.pdf","grobid_xml":"https://content.openalex.org/works/W4416581398.grobid-xml"},"referenced_works_count":19,"referenced_works":["https://openalex.org/W2766945077","https://openalex.org/W2913186716","https://openalex.org/W2942598770","https://openalex.org/W2949420711","https://openalex.org/W2957542766","https://openalex.org/W2963157523","https://openalex.org/W2990832264","https://openalex.org/W3036785826","https://openalex.org/W3044715923","https://openalex.org/W3056908629","https://openalex.org/W3120017033","https://openalex.org/W3127177343","https://openalex.org/W3155174489","https://openalex.org/W3177359091","https://openalex.org/W3205016666","https://openalex.org/W3215506111","https://openalex.org/W4225758930","https://openalex.org/W4233501705","https://openalex.org/W4285290009"],"related_works":[],"abstract_inverted_index":{"Abstract":[0],"This":[1,26],"study":[2],"proposes":[3],"a":[4,53,64,79,106,155],"distribution":[5,84,121,146],"line":[6,37],"fault":[7,19,54,72,137],"detection":[8,20],"and":[9,22,38,49,73,90,111,135,153],"location":[10],"technology":[11,27,104,149],"based":[12],"on":[13,35],"waveform":[14,50,130],"comparison,":[15,68],"aiming":[16],"to":[17,42,69],"improve":[18],"accuracy":[21],"shorten":[23],"analysis":[24],"time.":[25],"collects":[28],"current":[29],"data":[30,41],"at":[31],"multiple":[32],"measurement":[33],"points":[34],"the":[36,40,43,56,71,83,117,124,129,136],"transmits":[39],"central":[44],"system":[45],"for":[46,67],"feature":[47],"extraction":[48],"analysis.":[51],"When":[52],"occurs,":[55],"correlation":[57,131],"coefficient":[58,132],"between":[59],"waveforms":[60],"is":[61,127,133],"used":[62],"as":[63],"similarity":[65],"criterion":[66],"determine":[70],"locate":[74],"it":[75],"automatically.":[76],"By":[77],"establishing":[78],"simulation":[80,118],"model":[81],"of":[82,119,157],"network,":[85],"single-phase":[86],"grounding,":[87,89],"three-phase":[88],"short-circuit":[91],"faults":[92],"are":[93],"simulated.":[94],"Experimental":[95],"results":[96],"show":[97],"that":[98],"under":[99],"complex":[100],"working":[101],"conditions,":[102],"this":[103,148],"has":[105],"low":[107],"false":[108],"alarm":[109],"rate":[110],"high":[112],"positioning":[113],"accuracy.":[114],"Especially":[115],"in":[116,143],"conventional":[120],"networks,":[122,147],"when":[123],"grounding":[125],"resistance":[126],"low,":[128],"high,":[134],"point":[138],"can":[139,150],"be":[140],"accurately":[141],"located;":[142],"distributed":[144],"power":[145],"effectively":[151],"detect":[152],"find":[154],"variety":[156],"faults.":[158]},"counts_by_year":[],"updated_date":"2026-05-06T08:25:59.206177","created_date":"2025-11-25T00:00:00"}
