{"id":"https://openalex.org/W4415945926","doi":"https://doi.org/10.1515/auto-2025-0098","title":"Implementation of WAMPAC in the CLARO environment","display_name":"Implementation of WAMPAC in the CLARO environment","publication_year":2025,"publication_date":"2025-11-01","ids":{"openalex":"https://openalex.org/W4415945926","doi":"https://doi.org/10.1515/auto-2025-0098"},"language":"en","primary_location":{"id":"doi:10.1515/auto-2025-0098","is_oa":false,"landing_page_url":"https://doi.org/10.1515/auto-2025-0098","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102834327","display_name":"Artem Kashtanov","orcid":"https://orcid.org/0000-0002-6084-2184"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Artem Kashtanov","raw_affiliation_strings":["Otto von Guericke University , Magdeburg , Germany"],"raw_orcid":"https://orcid.org/0000-0002-6084-2184","affiliations":[{"raw_affiliation_string":"Otto von Guericke University , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5120273860","display_name":"Arpit Shah","orcid":"https://orcid.org/0009-0004-3191-8057"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Arpit Shah","raw_affiliation_strings":["Otto von Guericke University , Magdeburg , Germany"],"raw_orcid":"https://orcid.org/0009-0004-3191-8057","affiliations":[{"raw_affiliation_string":"Otto von Guericke University , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043231773","display_name":"Eric Glende","orcid":"https://orcid.org/0009-0002-7678-9215"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Eric Glende","raw_affiliation_strings":["Otto von Guericke University , Magdeburg , Germany"],"raw_orcid":"https://orcid.org/0009-0002-7678-9215","affiliations":[{"raw_affiliation_string":"Otto von Guericke University , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5120273861","display_name":"Shafaque Talpur","orcid":"https://orcid.org/0009-0003-3332-0078"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Shafaque Talpur","raw_affiliation_strings":["Otto von Guericke University , Magdeburg , Germany"],"raw_orcid":"https://orcid.org/0009-0003-3332-0078","affiliations":[{"raw_affiliation_string":"Otto von Guericke University , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042758411","display_name":"Martin Wolter","orcid":"https://orcid.org/0000-0003-0281-0501"},"institutions":[{"id":"https://openalex.org/I95793202","display_name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","ror":"https://ror.org/00ggpsq73","country_code":"DE","type":"education","lineage":["https://openalex.org/I95793202"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Wolter","raw_affiliation_strings":["Otto von Guericke University , Magdeburg , Germany"],"raw_orcid":"https://orcid.org/0000-0003-0281-0501","affiliations":[{"raw_affiliation_string":"Otto von Guericke University , Magdeburg , Germany","institution_ids":["https://openalex.org/I95793202"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I95793202"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.27021235,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"73","issue":"11","first_page":"868","last_page":"879"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.3183000087738037,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.3183000087738037,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12810","display_name":"Real-time simulation and control systems","score":0.2736999988555908,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.0820000022649765,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/workflow","display_name":"Workflow","score":0.5968000292778015},{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.5827999711036682},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5077999830245972},{"id":"https://openalex.org/keywords/event","display_name":"Event (particle physics)","score":0.4839000105857849},{"id":"https://openalex.org/keywords/supervisory-control","display_name":"Supervisory control","score":0.4625000059604645},{"id":"https://openalex.org/keywords/field","display_name":"Field (mathematics)","score":0.4595000147819519},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.45910000801086426},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4185999929904938},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.3644999861717224}],"concepts":[{"id":"https://openalex.org/C177212765","wikidata":"https://www.wikidata.org/wiki/Q627335","display_name":"Workflow","level":2,"score":0.5968000292778015},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.5827999711036682},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5630999803543091},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5077999830245972},{"id":"https://openalex.org/C2779662365","wikidata":"https://www.wikidata.org/wiki/Q5416694","display_name":"Event (particle physics)","level":2,"score":0.4839000105857849},{"id":"https://openalex.org/C92991967","wikidata":"https://www.wikidata.org/wiki/Q7644329","display_name":"Supervisory control","level":3,"score":0.4625000059604645},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4595000147819519},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.45910000801086426},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.4361000061035156},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.4235999882221222},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4185999929904938},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.41359999775886536},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3644999861717224},{"id":"https://openalex.org/C37785467","wikidata":"https://www.wikidata.org/wiki/Q385325","display_name":"Modelica","level":2,"score":0.36169999837875366},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3587000072002411},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.35499998927116394},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.34860000014305115},{"id":"https://openalex.org/C2779697362","wikidata":"https://www.wikidata.org/wiki/Q390516","display_name":"Control room","level":2,"score":0.34299999475479126},{"id":"https://openalex.org/C12269588","wikidata":"https://www.wikidata.org/wiki/Q132364","display_name":"Communications protocol","level":2,"score":0.3375000059604645},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.3343999981880188},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.32899999618530273},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.32850000262260437},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3224000036716461},{"id":"https://openalex.org/C2780974030","wikidata":"https://www.wikidata.org/wiki/Q16951926","display_name":"Co-simulation","level":2,"score":0.3224000036716461},{"id":"https://openalex.org/C38677869","wikidata":"https://www.wikidata.org/wiki/Q724168","display_name":"Petri net","level":2,"score":0.3100999891757965},{"id":"https://openalex.org/C48103436","wikidata":"https://www.wikidata.org/wiki/Q599031","display_name":"State (computer science)","level":2,"score":0.3068000078201294},{"id":"https://openalex.org/C73752529","wikidata":"https://www.wikidata.org/wiki/Q79872","display_name":"Object-oriented programming","level":2,"score":0.30169999599456787},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.2879999876022339},{"id":"https://openalex.org/C2781238097","wikidata":"https://www.wikidata.org/wiki/Q175026","display_name":"Object (grammar)","level":2,"score":0.2865000069141388},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.2759000062942505},{"id":"https://openalex.org/C70429105","wikidata":"https://www.wikidata.org/wiki/Q249999","display_name":"Grid computing","level":3,"score":0.2745000123977661},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.2605000138282776},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.25999999046325684},{"id":"https://openalex.org/C33933514","wikidata":"https://www.wikidata.org/wiki/Q525443","display_name":"Distributed control system","level":3,"score":0.2565000057220459}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1515/auto-2025-0098","is_oa":false,"landing_page_url":"https://doi.org/10.1515/auto-2025-0098","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1997081029","https://openalex.org/W2000177148","https://openalex.org/W2071538395","https://openalex.org/W2081078577","https://openalex.org/W2082931595","https://openalex.org/W2120966260","https://openalex.org/W2147070624","https://openalex.org/W2556121504","https://openalex.org/W2808533785","https://openalex.org/W3156995726","https://openalex.org/W3192446829","https://openalex.org/W3196049610","https://openalex.org/W4210538234","https://openalex.org/W4300782170","https://openalex.org/W4323644080","https://openalex.org/W4385696569","https://openalex.org/W4399801321","https://openalex.org/W4407362475"],"related_works":[],"abstract_inverted_index":{"Abstract":[0],"Wide-area":[1],"monitoring,":[2],"protection,":[3],"and":[4,39,65,131,146],"control":[5,109],"(WAMPAC)":[6],"systems":[7],"are":[8],"essential":[9],"for":[10],"ensuring":[11],"stability":[12],"in":[13],"modern":[14,66,150],"electric":[15],"power":[16],"grids":[17],"with":[18,128],"large":[19],"shares":[20],"of":[21,94,141],"converter-based":[22],"renewable":[23],"generation.":[24],"Laboratory":[25,38],"environments":[26],"allow":[27],"risk-free":[28],"validation":[29,145],"before":[30],"field":[31],"deployment.":[32],"Building":[33],"on":[34,90],"our":[35],"Control":[36,130],"Center":[37],"Real-Time":[40],"Simulation":[41],"(CLARO)":[42],"framework,":[43],"we":[44],"implement":[45],"complete":[46],"WAMPAC":[47,144],"workflows":[48],"that":[49],"couple":[50],"real-time":[51,75],"grid":[52,154],"simulation":[53],"(Opal-RT),":[54],"standardized":[55],"communication":[56],"protocols":[57],"(IEEE":[58],"C37.118,":[59],"IEC":[60,62],"61850,":[61],"60870-5-104,":[63],"Modbus),":[64],"information-technology/operational-technology":[67],"(IT/OT)":[68],"architectures":[69],"(Apache":[70],"Kafka,":[71],"Kubernetes,":[72],"containerization).":[73],"A":[74],"automation":[76],"controller":[77],"executes":[78],"corrective":[79],"actions":[80],"using":[81],"Generic":[82],"Object":[83],"Oriented":[84],"Substation":[85],"Event":[86],"(GOOSE)":[87],"messages":[88],"based":[89],"a":[91,97],"pre-computed":[92],"catalog":[93],"measures.":[95],"On":[96],"synthetic":[98],"118-bus":[99],"benchmark,":[100],"phasor-measurement-unit":[101],"(PMU)":[102],"driven":[103],"end-to-end":[104],"delays":[105],"from":[106],"disturbance":[107],"to":[108],"action":[110],"remain":[111],"below":[112],"250":[113],"ms,":[114],"while":[115],"PMU-enhanced":[116],"state":[117],"estimation":[118],"reduces":[119],"bus-voltage":[120],"magnitude":[121],"error":[122],"by":[123],"over":[124],"40":[125],"%":[126],"compared":[127],"Supervisory":[129],"Data":[132],"Acquisition":[133],"(SCADA)":[134],"only.":[135],"These":[136],"results":[137],"demonstrate":[138],"the":[139],"feasibility":[140],"realistic,":[142],"lab-based":[143],"highlight":[147],"how":[148],"integrating":[149],"IT/OT":[151],"stacks":[152],"strengthens":[153],"resilience.":[155]},"counts_by_year":[],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-11-06T00:00:00"}
