{"id":"https://openalex.org/W2552803232","doi":"https://doi.org/10.1515/auto-2016-0105","title":"Modeling and closed-loop control of a medical flow generator appliance","display_name":"Modeling and closed-loop control of a medical flow generator appliance","publication_year":2016,"publication_date":"2016-11-15","ids":{"openalex":"https://openalex.org/W2552803232","doi":"https://doi.org/10.1515/auto-2016-0105","mag":"2552803232"},"language":"en","primary_location":{"id":"doi:10.1515/auto-2016-0105","is_oa":false,"landing_page_url":"https://doi.org/10.1515/auto-2016-0105","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5028895601","display_name":"Mathias Scheel","orcid":null},"institutions":[{"id":"https://openalex.org/I162015237","display_name":"Wismar University of Applied Sciences","ror":"https://ror.org/00s1ckt27","country_code":"DE","type":"education","lineage":["https://openalex.org/I162015237"]},{"id":"https://openalex.org/I4210101162","display_name":"Helios Hospital Schwerin","ror":"https://ror.org/018gc9r78","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210101162","https://openalex.org/I4210138940"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"Mathias Scheel","raw_affiliation_strings":["Automation and Mechatronics Group \u2013 Hochschule Wismar, Philipp-M\u00fcller-Stra\u00dfe 14, 23966 Wismar, Germany Germany","HOFFRICHTER GmbH Schwerin, Mettenheimer Stra\u00dfe 12/14, 19061 Schwerin, Germany Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automation and Mechatronics Group \u2013 Hochschule Wismar, Philipp-M\u00fcller-Stra\u00dfe 14, 23966 Wismar, Germany Germany","institution_ids":["https://openalex.org/I162015237"]},{"raw_affiliation_string":"HOFFRICHTER GmbH Schwerin, Mettenheimer Stra\u00dfe 12/14, 19061 Schwerin, Germany Germany","institution_ids":["https://openalex.org/I4210101162"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070270548","display_name":"Andreas Berndt","orcid":null},"institutions":[{"id":"https://openalex.org/I4210101162","display_name":"Helios Hospital Schwerin","ror":"https://ror.org/018gc9r78","country_code":"DE","type":"healthcare","lineage":["https://openalex.org/I4210101162","https://openalex.org/I4210138940"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Andreas Berndt","raw_affiliation_strings":["HOFFRICHTER GmbH Schwerin, Mettenheimer Stra\u00dfe 12/14, 19061 Schwerin, Germany Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"HOFFRICHTER GmbH Schwerin, Mettenheimer Stra\u00dfe 12/14, 19061 Schwerin, Germany Germany","institution_ids":["https://openalex.org/I4210101162"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007409834","display_name":"Olaf Simanski","orcid":null},"institutions":[{"id":"https://openalex.org/I162015237","display_name":"Wismar University of Applied Sciences","ror":"https://ror.org/00s1ckt27","country_code":"DE","type":"education","lineage":["https://openalex.org/I162015237"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Olaf Simanski","raw_affiliation_strings":["Automation and Mechatronics Group \u2013 Hochschule Wismar, Philipp-M\u00fcller-Stra\u00dfe 14, 23966 Wismar, Germany Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Automation and Mechatronics Group \u2013 Hochschule Wismar, Philipp-M\u00fcller-Stra\u00dfe 14, 23966 Wismar, Germany Germany","institution_ids":["https://openalex.org/I162015237"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5028895601"],"corresponding_institution_ids":["https://openalex.org/I162015237","https://openalex.org/I4210101162"],"apc_list":null,"apc_paid":null,"fwci":0.1706,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.58302971,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":"64","issue":"11","first_page":"870","last_page":"877"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11608","display_name":"Dielectric materials and actuators","score":0.9688000082969666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11608","display_name":"Dielectric materials and actuators","score":0.9688000082969666,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10322","display_name":"Respiratory Support and Mechanisms","score":0.9380999803543091,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11192","display_name":"Underwater Vehicles and Communication Systems","score":0.9283000230789185,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/continuous-positive-airway-pressure","display_name":"Continuous positive airway pressure","score":0.7116771340370178},{"id":"https://openalex.org/keywords/pressure-control","display_name":"Pressure control","score":0.579897403717041},{"id":"https://openalex.org/keywords/breathing","display_name":"Breathing","score":0.5043133497238159},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4743439257144928},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4711954593658447},{"id":"https://openalex.org/keywords/positive-pressure","display_name":"Positive pressure","score":0.4689922630786896},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.46084925532341003},{"id":"https://openalex.org/keywords/work-of-breathing","display_name":"Work of breathing","score":0.4559633433818817},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4345616102218628},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.4103120267391205},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.35459786653518677},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.25966131687164307},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24147960543632507},{"id":"https://openalex.org/keywords/mechanical-ventilation","display_name":"Mechanical ventilation","score":0.1925276219844818},{"id":"https://openalex.org/keywords/obstructive-sleep-apnea","display_name":"Obstructive sleep apnea","score":0.18030601739883423},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.12381699681282043}],"concepts":[{"id":"https://openalex.org/C2779547634","wikidata":"https://www.wikidata.org/wiki/Q5165502","display_name":"Continuous positive airway pressure","level":3,"score":0.7116771340370178},{"id":"https://openalex.org/C2781153586","wikidata":"https://www.wikidata.org/wiki/Q7241717","display_name":"Pressure control","level":2,"score":0.579897403717041},{"id":"https://openalex.org/C39300077","wikidata":"https://www.wikidata.org/wiki/Q9530","display_name":"Breathing","level":2,"score":0.5043133497238159},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4743439257144928},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4711954593658447},{"id":"https://openalex.org/C204832983","wikidata":"https://www.wikidata.org/wiki/Q331466","display_name":"Positive pressure","level":2,"score":0.4689922630786896},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.46084925532341003},{"id":"https://openalex.org/C2776924770","wikidata":"https://www.wikidata.org/wiki/Q23808249","display_name":"Work of breathing","level":3,"score":0.4559633433818817},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4345616102218628},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.4103120267391205},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.35459786653518677},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.25966131687164307},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24147960543632507},{"id":"https://openalex.org/C2777080012","wikidata":"https://www.wikidata.org/wiki/Q3766250","display_name":"Mechanical ventilation","level":2,"score":0.1925276219844818},{"id":"https://openalex.org/C2776006263","wikidata":"https://www.wikidata.org/wiki/Q16606552","display_name":"Obstructive sleep apnea","level":2,"score":0.18030601739883423},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.12381699681282043},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1515/auto-2016-0105","is_oa":false,"landing_page_url":"https://doi.org/10.1515/auto-2016-0105","pdf_url":null,"source":{"id":"https://openalex.org/S4210170077","display_name":"at - Automatisierungstechnik","issn_l":"0178-2312","issn":["0178-2312","2196-677X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319967","host_organization_name":"R. Oldenbourg Verlag","host_organization_lineage":["https://openalex.org/P4310319967"],"host_organization_lineage_names":["R. Oldenbourg Verlag"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"at - Automatisierungstechnik","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7799999713897705,"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2400763449","https://openalex.org/W2131953701","https://openalex.org/W2399005373","https://openalex.org/W4386231388","https://openalex.org/W2089041809","https://openalex.org/W2330619474","https://openalex.org/W2080022935","https://openalex.org/W2000448022","https://openalex.org/W1971121870","https://openalex.org/W2188571775"],"abstract_inverted_index":{"Abstract":[0],"The":[1,34,44],"CPAP":[2],"(Continuous":[3],"Positive":[4],"Airway":[5],"Pressure)":[6],"therapy":[7,12,97],"is":[8,49,78,99,121,134],"the":[9,15,21,42,47,69,75,82,88,95,112,124],"most":[10],"common":[11],"to":[13,29,40,53,101],"treat":[14],"obstructive":[16],"sleep":[17],"apnoea":[18],"syndrome.":[19],"If":[20],"upper":[22],"respiratory":[23],"tracts":[24],"collapse,":[25],"it":[26],"may":[27],"lead":[28],"breathing":[30,96],"interrupts":[31],"during":[32],"sleep.":[33],"CPAP-device":[35],"provides":[36],"a":[37,106,132],"positive":[38],"pressure":[39,48,71,77],"splint":[41],"airways.":[43],"influence":[45],"on":[46,111],"different":[50],"from":[51],"patient":[52,54],"and":[55,91,131],"their":[56],"medical":[57],"condition.":[58],"It":[59],"has":[60],"been":[61],"shown":[62,130],"that":[63],"many":[64],"CPAP-devices":[65],"can":[66],"not":[67],"maintain":[68],"required":[70],"set":[72],"points,":[73],"because":[74],"mask":[76],"seriously":[79],"influenced":[80],"by":[81],"patient's":[83],"breathing.":[84],"In":[85,123],"this":[86],"work":[87],"electromechanic":[89],"part":[90,93],"pneumatic":[92],"of":[94,115],"system":[98],"modeled":[100],"provide":[102],"an":[103,117],"opportunity":[104],"for":[105],"model-based":[107],"control":[108,119,127],"approach.":[109],"Based":[110],"physical":[113],"chain":[114],"effect":[116],"existing":[118],"strategy":[120],"extended.":[122],"end":[125],"some":[126],"results":[128],"are":[129],"conclusion":[133],"made.":[135]},"counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
