{"id":"https://openalex.org/W2765523324","doi":"https://doi.org/10.1504/ijaac.2018.10008724","title":"Load frequency control of multi-area interconnected thermal power system: artificial intelligence-based approach","display_name":"Load frequency control of multi-area interconnected thermal power system: artificial intelligence-based approach","publication_year":2017,"publication_date":"2017-10-30","ids":{"openalex":"https://openalex.org/W2765523324","doi":"https://doi.org/10.1504/ijaac.2018.10008724","mag":"2765523324"},"language":"en","primary_location":{"id":"doi:10.1504/ijaac.2018.10008724","is_oa":false,"landing_page_url":"https://doi.org/10.1504/ijaac.2018.10008724","pdf_url":null,"source":{"id":"https://openalex.org/S33985172","display_name":"International Journal of Automation and Control","issn_l":"1740-7516","issn":["1740-7516","1740-7524"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310317825","host_organization_name":"Inderscience Publishers","host_organization_lineage":["https://openalex.org/P4310317825"],"host_organization_lineage_names":["Inderscience Publishers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Automation and Control","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5071729841","display_name":"K. Jagatheesan","orcid":"https://orcid.org/0000-0002-2957-3502"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Kaliannan Jagatheesan","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Mahendra Institute of Engineering and Technology, Namakkal, Tamil Nadu, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Mahendra Institute of Engineering and Technology, Namakkal, Tamil Nadu, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5104123061","display_name":"Baskaran Anand","orcid":null},"institutions":[{"id":"https://openalex.org/I43663321","display_name":"Hindustan Institute of Technology and Science","ror":"https://ror.org/037tgdn13","country_code":"IN","type":"education","lineage":["https://openalex.org/I43663321"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Baskaran Anand","raw_affiliation_strings":["Department of Electrical and Electronics Engineering, Hindusthan College of Engineering and Technology, Coimbatore, Tamil Nadu, India"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronics Engineering, Hindusthan College of Engineering and Technology, Coimbatore, Tamil Nadu, India","institution_ids":["https://openalex.org/I43663321"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000355426","display_name":"Valentina Emilia B\u0103la\u015f","orcid":"https://orcid.org/0000-0003-0885-1283"},"institutions":[{"id":"https://openalex.org/I1288043984","display_name":"Techno India University","ror":"https://ror.org/00v1y6t69","country_code":"IN","type":"education","lineage":["https://openalex.org/I1288043984"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Valentina E. Balas","raw_affiliation_strings":["Department of Information Technology, Techno India College of Technology, West Bengal, India"],"affiliations":[{"raw_affiliation_string":"Department of Information Technology, Techno India College of Technology, West Bengal, India","institution_ids":["https://openalex.org/I1288043984"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000975435","display_name":"Nilanjan Dey","orcid":"https://orcid.org/0000-0001-8437-498X"},"institutions":[{"id":"https://openalex.org/I21376657","display_name":"Tanta University","ror":"https://ror.org/016jp5b92","country_code":"EG","type":"education","lineage":["https://openalex.org/I21376657"]}],"countries":["EG"],"is_corresponding":false,"raw_author_name":"Nilanjan Dey","raw_affiliation_strings":["Department of Electronics and Electrical Communications Engineering, Faculty of Engineering, Tanta University, Tanta, Egypt"],"affiliations":[{"raw_affiliation_string":"Department of Electronics and Electrical Communications Engineering, Faculty of Engineering, Tanta University, Tanta, Egypt","institution_ids":["https://openalex.org/I21376657"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5068271733","display_name":"Amira S. Ashour","orcid":"https://orcid.org/0000-0003-3217-6185"},"institutions":[{"id":"https://openalex.org/I64956957","display_name":"Aurel Vlaicu University of Arad","ror":"https://ror.org/05w5rsy15","country_code":"RO","type":"education","lineage":["https://openalex.org/I64956957"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"Amira S. Ashour","raw_affiliation_strings":["Faculty of Engineering, Aurel Vlaicu University of Arad, Arad, Romania"],"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, Aurel Vlaicu University of Arad, Arad, Romania","institution_ids":["https://openalex.org/I64956957"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5071729841"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.13706033,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"12","issue":"1","first_page":"126","last_page":"126"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9929999709129333,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9611999988555908,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.6222109794616699},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5243219137191772},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4637468457221985},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.441173791885376},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.43919575214385986},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.43055906891822815},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.40611976385116577},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.38061079382896423},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.33092546463012695},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.21880251169204712}],"concepts":[{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6222109794616699},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5243219137191772},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4637468457221985},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.441173791885376},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.43919575214385986},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.43055906891822815},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.40611976385116577},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.38061079382896423},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.33092546463012695},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.21880251169204712},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1504/ijaac.2018.10008724","is_oa":false,"landing_page_url":"https://doi.org/10.1504/ijaac.2018.10008724","pdf_url":null,"source":{"id":"https://openalex.org/S33985172","display_name":"International Journal of Automation and Control","issn_l":"1740-7516","issn":["1740-7516","1740-7524"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310317825","host_organization_name":"Inderscience Publishers","host_organization_lineage":["https://openalex.org/P4310317825"],"host_organization_lineage_names":["Inderscience Publishers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Automation and Control","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":38,"referenced_works":["https://openalex.org/W1507837710","https://openalex.org/W1763243278","https://openalex.org/W1971421925","https://openalex.org/W1988840686","https://openalex.org/W2008620264","https://openalex.org/W2017987256","https://openalex.org/W2019009079","https://openalex.org/W2021253717","https://openalex.org/W2025543856","https://openalex.org/W2028270345","https://openalex.org/W2035702630","https://openalex.org/W2038920443","https://openalex.org/W2047940964","https://openalex.org/W2063961010","https://openalex.org/W2067841476","https://openalex.org/W2075974113","https://openalex.org/W2076934128","https://openalex.org/W2086805702","https://openalex.org/W2089458547","https://openalex.org/W2090823085","https://openalex.org/W2095293504","https://openalex.org/W2099645570","https://openalex.org/W2111642621","https://openalex.org/W2112090702","https://openalex.org/W2117360709","https://openalex.org/W2121947440","https://openalex.org/W2127048411","https://openalex.org/W2128366083","https://openalex.org/W2131681506","https://openalex.org/W2139470852","https://openalex.org/W2154897810","https://openalex.org/W2155167324","https://openalex.org/W2164928285","https://openalex.org/W2168346701","https://openalex.org/W2169971762","https://openalex.org/W2325627303","https://openalex.org/W3102630674","https://openalex.org/W3103786587"],"related_works":["https://openalex.org/W4376453582","https://openalex.org/W3147033875","https://openalex.org/W2764722704","https://openalex.org/W1568390478","https://openalex.org/W318913410","https://openalex.org/W2355543518","https://openalex.org/W4205240067","https://openalex.org/W2155742919","https://openalex.org/W2145753860","https://openalex.org/W2989018981"],"abstract_inverted_index":{"In":[0],"the":[1,19,22,34,68,87,95],"current":[2],"work,":[3],"an":[4],"ant":[5],"colony":[6],"optimisation":[7,9],"(ACO)":[8],"technique":[10],"for":[11,17],"load":[12],"frequency":[13],"control":[14],"was":[15,51],"proposed":[16],"tuning":[18],"performance":[20],"of":[21,41,86],"proportional-integral-derivative":[23],"(PID)":[24,49],"controller":[25,50,55],"gain":[26,56],"values.":[27],"This":[28],"led":[29],"to":[30],"oscillations":[31],"suppression":[32],"in":[33,94],"power":[35],"system":[36,39,96],"response.":[37],"A":[38],"consisted":[40],"three":[42,62],"equal":[43],"thermal":[44],"generating":[45],"units":[46],"equipped":[47],"with":[48],"investigated.":[52],"The":[53],"PID":[54],"values":[57],"are":[58],"obtained":[59],"by":[60],"using":[61],"different":[63],"cost":[64],"functions":[65],"such":[66],"as":[67],"integral":[69,73,79],"square":[70],"error":[71,76,81],"(ISE),":[72],"time":[74,89],"absolute":[75,80],"(ITAE)":[77],"and":[78,90],"(IAE).":[82],"Time":[83],"domain":[84],"specifications":[85],"settling":[88],"overshoot":[91],"were":[92],"considered":[93],"response":[97],"analysis.":[98]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2021,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
