{"id":"https://openalex.org/W7128512961","doi":"https://doi.org/10.1186/s42162-026-00638-5","title":"Capacity optimization allocation and stability of new energy wind power generation and hybrid energy storage systems","display_name":"Capacity optimization allocation and stability of new energy wind power generation and hybrid energy storage systems","publication_year":2026,"publication_date":"2026-02-10","ids":{"openalex":"https://openalex.org/W7128512961","doi":"https://doi.org/10.1186/s42162-026-00638-5"},"language":"en","primary_location":{"id":"doi:10.1186/s42162-026-00638-5","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00638-5","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1186/s42162-026-00638-5","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056985351","display_name":"Linyan Tang","orcid":"https://orcid.org/0000-0003-3427-1573"},"institutions":[{"id":"https://openalex.org/I4210163048","display_name":"Jiangxi College of Applied Technology","ror":"https://ror.org/05d5kcc69","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163048"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Linyan Tang","raw_affiliation_strings":["Department of Power Engineering, Jiangxi Electric Vocational and Technical College, Nanchang, 330000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Engineering, Jiangxi Electric Vocational and Technical College, Nanchang, 330000, China","institution_ids":["https://openalex.org/I4210163048"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5125497048","display_name":"Zhiming Huang","orcid":null},"institutions":[{"id":"https://openalex.org/I4210163048","display_name":"Jiangxi College of Applied Technology","ror":"https://ror.org/05d5kcc69","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163048"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiming Huang","raw_affiliation_strings":["Department of Power Engineering, Jiangxi Electric Vocational and Technical College, Nanchang, 330000, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Engineering, Jiangxi Electric Vocational and Technical College, Nanchang, 330000, China","institution_ids":["https://openalex.org/I4210163048"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5056985351"],"corresponding_institution_ids":["https://openalex.org/I4210163048"],"apc_list":{"value":790,"currency":"GBP","value_usd":1340},"apc_paid":{"value":790,"currency":"GBP","value_usd":1340},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.14390178,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"9","issue":"1","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9369999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9369999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.02250000089406967,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.006899999920278788,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.6700999736785889},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.5867000222206116},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5378000140190125},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4884999990463257},{"id":"https://openalex.org/keywords/capacity-optimization","display_name":"Capacity optimization","score":0.46140000224113464},{"id":"https://openalex.org/keywords/battery","display_name":"Battery (electricity)","score":0.4498000144958496},{"id":"https://openalex.org/keywords/multi-objective-optimization","display_name":"Multi-objective optimization","score":0.44679999351501465},{"id":"https://openalex.org/keywords/stability","display_name":"Stability (learning theory)","score":0.4456999897956848},{"id":"https://openalex.org/keywords/electricity-generation","display_name":"Electricity generation","score":0.3917999863624573}],"concepts":[{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.6700999736785889},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5867000222206116},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5378000140190125},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4884999990463257},{"id":"https://openalex.org/C2776469763","wikidata":"https://www.wikidata.org/wiki/Q5034491","display_name":"Capacity optimization","level":3,"score":0.46140000224113464},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.4498000144958496},{"id":"https://openalex.org/C68781425","wikidata":"https://www.wikidata.org/wiki/Q2052203","display_name":"Multi-objective optimization","level":2,"score":0.44679999351501465},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4465999901294708},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.4456999897956848},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.3917999863624573},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.38690000772476196},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.37860000133514404},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3785000145435333},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3779999911785126},{"id":"https://openalex.org/C137635306","wikidata":"https://www.wikidata.org/wiki/Q182667","display_name":"Pareto principle","level":2,"score":0.37619999051094055},{"id":"https://openalex.org/C194739806","wikidata":"https://www.wikidata.org/wiki/Q66221","display_name":"Computer data storage","level":2,"score":0.3741999864578247},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.35280001163482666},{"id":"https://openalex.org/C2780685028","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Grid connection","level":3,"score":0.34599998593330383},{"id":"https://openalex.org/C123919525","wikidata":"https://www.wikidata.org/wiki/Q761942","display_name":"Frequency deviation","level":3,"score":0.337799996137619},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.32829999923706055},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.32260000705718994},{"id":"https://openalex.org/C22679943","wikidata":"https://www.wikidata.org/wiki/Q159375","display_name":"Standard deviation","level":2,"score":0.3125999867916107},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3050999939441681},{"id":"https://openalex.org/C2778439541","wikidata":"https://www.wikidata.org/wiki/Q7106412","display_name":"Oscillation (cell signaling)","level":2,"score":0.2937999963760376},{"id":"https://openalex.org/C2780106510","wikidata":"https://www.wikidata.org/wiki/Q4822597","display_name":"Depth of discharge","level":4,"score":0.2921000123023987},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.28690001368522644},{"id":"https://openalex.org/C161067210","wikidata":"https://www.wikidata.org/wiki/Q1464943","display_name":"Wind speed","level":2,"score":0.26980000734329224},{"id":"https://openalex.org/C86155754","wikidata":"https://www.wikidata.org/wiki/Q13636979","display_name":"Hybrid power","level":3,"score":0.2669999897480011},{"id":"https://openalex.org/C2778925954","wikidata":"https://www.wikidata.org/wiki/Q16883749","display_name":"Stability criterion","level":3,"score":0.2632000148296356},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2615000009536743}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1186/s42162-026-00638-5","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00638-5","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:ff498c7fabd84fc58012cf8e64e3e51c","is_oa":true,"landing_page_url":"https://doaj.org/article/ff498c7fabd84fc58012cf8e64e3e51c","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energy Informatics, Vol 9, Iss 1 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1186/s42162-026-00638-5","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00638-5","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Responsible consumption and production","id":"https://metadata.un.org/sdg/12","score":0.44429755210876465}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W3193546503","https://openalex.org/W4200339765","https://openalex.org/W4213007008","https://openalex.org/W4221036627","https://openalex.org/W4286489440","https://openalex.org/W4292661074","https://openalex.org/W4316096795","https://openalex.org/W4361988330","https://openalex.org/W4379800406","https://openalex.org/W4385191469","https://openalex.org/W4385731830","https://openalex.org/W4390675710","https://openalex.org/W4390905656","https://openalex.org/W4390952177","https://openalex.org/W4392593542","https://openalex.org/W4400111113","https://openalex.org/W4400386782","https://openalex.org/W4405327785","https://openalex.org/W4406070924","https://openalex.org/W4408540025"],"related_works":[],"abstract_inverted_index":{"To":[0],"solve":[1],"the":[2,40,69,77,101,105,117,122,126,144,161,173,184,198,206,210,225,240],"power":[3,13,29,83,90,146,178,262],"fluctuation":[4,147],"and":[5,23,31,58,80,85,116,142,223,252,264,269],"system":[6,167,202,257],"stability":[7,24],"problems":[8],"caused":[9],"by":[10,179,192,229],"large-scale":[11],"wind":[12,28,261],"grid":[14],"connection,":[15],"this":[16,61],"study":[17,62,106,241],"proposes":[18],"a":[19,64,87,133,155,218,232,243],"capacity":[20],"optimization":[21,66,114],"configuration":[22,46,131],"improvement":[25],"strategy":[26],"for":[27,217,254],"generation":[30],"battery-supercapacitor":[32],"hybrid":[33,164,199],"energy":[34,44,158,165,200,255],"storage":[35,45,159,166,201,256],"systems.":[36],"In":[37],"view":[38],"of":[39,42,71,89,138,176,189,209],"shortcomings":[41],"traditional":[43],"methods":[47],"that":[48,100,197,246],"fail":[49],"to":[50,150,221],"take":[51],"into":[52,248],"account":[53,249],"full":[54],"life":[55,78],"cycle":[56,79],"economics":[57],"dynamic":[59],"stability,":[60],"established":[63],"two-layer":[65],"model":[67,102],"with":[68,154],"goal":[70],"lowest":[72],"annual":[73,135],"average":[74,136,185],"cost":[75,137],"throughout":[76],"minimal":[81],"grid-connected":[82,145,177],"fluctuations,":[84],"designed":[86],"set":[88],"allocation":[91],"strategies":[92],"based":[93],"on":[94],"frequency":[95],"decoupling.":[96],"The":[97,129,236],"results":[98],"revealed":[99],"proposed":[103,238],"in":[104,113,125,239],"was":[107],"better":[108],"than":[109],"four":[110],"advanced":[111],"algorithms":[112],"performance,":[115],"Pareto":[118],"front":[119],"obtained":[120],"reached":[121],"highest":[123],"0.782":[124],"hypervolume":[127],"index.":[128],"optimized":[130],"achieves":[132],"minimum":[134],"1.887":[139],"million":[140],"yuan":[141],"limits":[143],"standard":[148,174],"deviation":[149,175],"124.6":[151],"kW.":[152],"Compared":[153],"single":[156,219],"battery":[157,190,220],"solution,":[160],"optimally":[162],"configured":[163],"could":[168,204],"not":[169],"only":[170],"further":[171],"reduce":[172,183],"6.7%,":[180],"but":[181],"also":[182],"daily":[186],"equivalent":[187],"number":[188],"cycles":[191],"38.5%.":[193],"Stability":[194],"analysis":[195],"verified":[196],"solution":[203,245],"increase":[205],"damping":[207],"ratio":[208],"system\u2019s":[211],"dominant":[212],"oscillation":[213],"mode":[214],"from":[215],"0.058":[216],"0.124,":[222],"shorten":[224],"voltage":[226],"recovery":[227],"time":[228],"21.2%":[230],"under":[231,259],"three-phase":[233],"short-circuit":[234],"fault.":[235],"method":[237],"provides":[242],"systematic":[244],"takes":[247],"both":[250],"economy":[251],"safety":[253],"planning":[258],"high-proportion":[260],"access,":[263],"has":[265],"important":[266],"theoretical":[267],"value":[268],"engineering":[270],"application":[271],"prospects.":[272]},"counts_by_year":[],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2026-02-11T00:00:00"}
