{"id":"https://openalex.org/W4308208159","doi":"https://doi.org/10.1177/09596518221133472","title":"Nonlinear cascade sliding mode control based on extended state observer method for a DC-DC buck converter: Design and hardware experimentation","display_name":"Nonlinear cascade sliding mode control based on extended state observer method for a DC-DC buck converter: Design and hardware experimentation","publication_year":2022,"publication_date":"2022-11-04","ids":{"openalex":"https://openalex.org/W4308208159","doi":"https://doi.org/10.1177/09596518221133472"},"language":"en","primary_location":{"id":"doi:10.1177/09596518221133472","is_oa":false,"landing_page_url":"https://doi.org/10.1177/09596518221133472","pdf_url":null,"source":{"id":"https://openalex.org/S4210196624","display_name":"Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering","issn_l":"0959-6518","issn":["0959-6518","2041-3041"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100421060","display_name":"Juan Li","orcid":"https://orcid.org/0000-0003-0905-7188"},"institutions":[{"id":"https://openalex.org/I78978612","display_name":"Yangzhou University","ror":"https://ror.org/03tqb8s11","country_code":"CN","type":"education","lineage":["https://openalex.org/I78978612"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Juan Li","raw_affiliation_strings":["College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","institution_ids":["https://openalex.org/I78978612"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021878630","display_name":"Shuwang Wang","orcid":null},"institutions":[{"id":"https://openalex.org/I76569877","display_name":"Southeast University","ror":"https://ror.org/04ct4d772","country_code":"CN","type":"education","lineage":["https://openalex.org/I76569877"]},{"id":"https://openalex.org/I78978612","display_name":"Yangzhou University","ror":"https://ror.org/03tqb8s11","country_code":"CN","type":"education","lineage":["https://openalex.org/I78978612"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shuwang Wang","raw_affiliation_strings":["College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","School of Cyber Science and Engineering, Southeast University, Nanjing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","institution_ids":["https://openalex.org/I78978612"]},{"raw_affiliation_string":"School of Cyber Science and Engineering, Southeast University, Nanjing, China","institution_ids":["https://openalex.org/I76569877"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100447109","display_name":"Luyao Zhang","orcid":"https://orcid.org/0000-0002-6105-4278"},"institutions":[{"id":"https://openalex.org/I78978612","display_name":"Yangzhou University","ror":"https://ror.org/03tqb8s11","country_code":"CN","type":"education","lineage":["https://openalex.org/I78978612"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Luyao Zhang","raw_affiliation_strings":["College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","institution_ids":["https://openalex.org/I78978612"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049939894","display_name":"Shengquan Li","orcid":"https://orcid.org/0000-0003-4208-6319"},"institutions":[{"id":"https://openalex.org/I78978612","display_name":"Yangzhou University","ror":"https://ror.org/03tqb8s11","country_code":"CN","type":"education","lineage":["https://openalex.org/I78978612"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shengquan Li","raw_affiliation_strings":["College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China"],"raw_orcid":"https://orcid.org/0000-0003-4208-6319","affiliations":[{"raw_affiliation_string":"College of Electrical, Energy and Power Engineering, Yangzhou University, Yangzhou, China","institution_ids":["https://openalex.org/I78978612"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.265,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.51941357,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":98},"biblio":{"volume":"237","issue":"4","first_page":"608","last_page":"621"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9954000115394592,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.992900013923645,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.90565025806427},{"id":"https://openalex.org/keywords/cascade","display_name":"Cascade","score":0.8809293508529663},{"id":"https://openalex.org/keywords/state-observer","display_name":"State observer","score":0.7942743301391602},{"id":"https://openalex.org/keywords/sliding-mode-control","display_name":"Sliding mode control","score":0.7368139028549194},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.6499091386795044},{"id":"https://openalex.org/keywords/observer","display_name":"Observer (physics)","score":0.5981723666191101},{"id":"https://openalex.org/keywords/convergence","display_name":"Convergence (economics)","score":0.5074138045310974},{"id":"https://openalex.org/keywords/buck-converter","display_name":"Buck converter","score":0.5030471682548523},{"id":"https://openalex.org/keywords/lyapunov-function","display_name":"Lyapunov function","score":0.46585923433303833},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4307449460029602},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31320494413375854},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.30950552225112915},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1846987009048462},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12525343894958496},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.052025943994522095}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.90565025806427},{"id":"https://openalex.org/C34146451","wikidata":"https://www.wikidata.org/wiki/Q5048094","display_name":"Cascade","level":2,"score":0.8809293508529663},{"id":"https://openalex.org/C3031470","wikidata":"https://www.wikidata.org/wiki/Q818544","display_name":"State observer","level":3,"score":0.7942743301391602},{"id":"https://openalex.org/C36662352","wikidata":"https://www.wikidata.org/wiki/Q6008560","display_name":"Sliding mode control","level":3,"score":0.7368139028549194},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.6499091386795044},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.5981723666191101},{"id":"https://openalex.org/C2777303404","wikidata":"https://www.wikidata.org/wiki/Q759757","display_name":"Convergence (economics)","level":2,"score":0.5074138045310974},{"id":"https://openalex.org/C150818752","wikidata":"https://www.wikidata.org/wiki/Q83804","display_name":"Buck converter","level":3,"score":0.5030471682548523},{"id":"https://openalex.org/C60640748","wikidata":"https://www.wikidata.org/wiki/Q2337858","display_name":"Lyapunov function","level":3,"score":0.46585923433303833},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4307449460029602},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31320494413375854},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.30950552225112915},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1846987009048462},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12525343894958496},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.052025943994522095},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C42360764","wikidata":"https://www.wikidata.org/wiki/Q83588","display_name":"Chemical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C50522688","wikidata":"https://www.wikidata.org/wiki/Q189833","display_name":"Economic growth","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/09596518221133472","is_oa":false,"landing_page_url":"https://doi.org/10.1177/09596518221133472","pdf_url":null,"source":{"id":"https://openalex.org/S4210196624","display_name":"Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering","issn_l":"0959-6518","issn":["0959-6518","2041-3041"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1999558720","https://openalex.org/W2030921129","https://openalex.org/W2053406538","https://openalex.org/W2062529350","https://openalex.org/W2074368529","https://openalex.org/W2135493101","https://openalex.org/W2142552638","https://openalex.org/W2320427981","https://openalex.org/W2518748083","https://openalex.org/W2530338644","https://openalex.org/W2552104267","https://openalex.org/W2606306225","https://openalex.org/W2735375376","https://openalex.org/W2765911046","https://openalex.org/W2908735293","https://openalex.org/W2920420800","https://openalex.org/W2955828514","https://openalex.org/W2960997853","https://openalex.org/W2970102598","https://openalex.org/W2999646202","https://openalex.org/W3000154329","https://openalex.org/W3001559633","https://openalex.org/W3093181118","https://openalex.org/W3143573289","https://openalex.org/W3183115195","https://openalex.org/W4200103194"],"related_works":["https://openalex.org/W2366453400","https://openalex.org/W2365259725","https://openalex.org/W2394201814","https://openalex.org/W1532194495","https://openalex.org/W2511965278","https://openalex.org/W2113447317","https://openalex.org/W1948712915","https://openalex.org/W4205434950","https://openalex.org/W3123253234","https://openalex.org/W2111927334"],"abstract_inverted_index":{"A":[0],"nonlinear":[1,80,123],"cascade":[2,82,124,135,149],"sliding":[3,83,125,136,150],"mode":[4,84,126,137,151],"control":[5,85,127,138,145,152],"(NLCSMC)":[6],"based":[7,108,128,153],"on":[8,109,129,154],"extended":[9,57,130,140,155],"state":[10,58,65,131,141,156],"observer":[11,59,132,157],"method":[12,86,133],"is":[13,60,87,106],"developed":[14],"for":[15],"a":[16,46,78],"DC-DC":[17,39],"buck":[18,40],"converter":[19,41],"in":[20,28,38],"the":[21,33,64,70,98,103,122],"presence":[22],"of":[23,69,102],"matched":[24,34,48],"disturbances":[25,37,68],"and":[26,35,52,67,93,114],"uncertainties":[27],"this":[29],"paper.":[30],"First,":[31],"all":[32],"mismatched":[36],"have":[42],"been":[43],"defined":[44],"as":[45],"uniformed":[47],"disturbance,":[49],"including":[50],"load":[51],"input":[53],"voltage":[54],"variations.":[55],"Second,":[56],"used":[61],"to":[62,89,120],"estimate":[63],"variables":[66],"system":[71,105],"that":[72],"cannot":[73],"be":[74],"obtained":[75],"directly.":[76],"Third,":[77],"novel":[79],"function-based":[81],"proposed":[88],"achieve":[90],"better":[91,144],"convergence":[92,100],"disturbance":[94],"rejection":[95],"ability.":[96],"Subsequently,":[97],"detailed":[99],"analysis":[101],"closed-loop":[104],"derived":[107],"Lyapunov":[110],"tools.":[111],"Finally,":[112],"simulation":[113],"experimental":[115],"results":[116],"are":[117],"carried":[118],"out":[119],"illustrate":[121],"(nonlinear":[134],"-":[139],"observer)":[142],"has":[143],"performance":[146],"than":[147],"linear":[148],"method.":[158]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":2}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
