{"id":"https://openalex.org/W3158897617","doi":"https://doi.org/10.1177/09596518211013169","title":"Using extended Kalman filter for failure detection and prognostic of degradation process in feedback control system","display_name":"Using extended Kalman filter for failure detection and prognostic of degradation process in feedback control system","publication_year":2021,"publication_date":"2021-05-03","ids":{"openalex":"https://openalex.org/W3158897617","doi":"https://doi.org/10.1177/09596518211013169","mag":"3158897617"},"language":"en","primary_location":{"id":"doi:10.1177/09596518211013169","is_oa":false,"landing_page_url":"https://doi.org/10.1177/09596518211013169","pdf_url":null,"source":{"id":"https://openalex.org/S4210196624","display_name":"Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering","issn_l":"0959-6518","issn":["0959-6518","2041-3041"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027681626","display_name":"Med Hedi Moulahi","orcid":"https://orcid.org/0000-0001-5897-8069"},"institutions":[{"id":"https://openalex.org/I108714496","display_name":"Tunis University","ror":"https://ror.org/02q1spa57","country_code":"TN","type":"education","lineage":["https://openalex.org/I108714496"]}],"countries":["TN"],"is_corresponding":true,"raw_author_name":"Med Hedi Moulahi","raw_affiliation_strings":["Laboratory LISIER, National High School of Engineers of Tunis, Universit\u00e9 de Tunis, Tunis, Tunisia"],"raw_orcid":"https://orcid.org/0000-0001-5897-8069","affiliations":[{"raw_affiliation_string":"Laboratory LISIER, National High School of Engineers of Tunis, Universit\u00e9 de Tunis, Tunis, Tunisia","institution_ids":["https://openalex.org/I108714496"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056730737","display_name":"Fay\u00e7al Ben Hmida","orcid":"https://orcid.org/0000-0002-9419-7873"},"institutions":[{"id":"https://openalex.org/I108714496","display_name":"Tunis University","ror":"https://ror.org/02q1spa57","country_code":"TN","type":"education","lineage":["https://openalex.org/I108714496"]}],"countries":["TN"],"is_corresponding":false,"raw_author_name":"Faycal Ben Hmida","raw_affiliation_strings":["Laboratory LISIER, National High School of Engineers of Tunis, Universit\u00e9 de Tunis, Tunis, Tunisia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratory LISIER, National High School of Engineers of Tunis, Universit\u00e9 de Tunis, Tunis, Tunisia","institution_ids":["https://openalex.org/I108714496"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5027681626"],"corresponding_institution_ids":["https://openalex.org/I108714496"],"apc_list":null,"apc_paid":null,"fwci":1.3336,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.78328078,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"236","issue":"1","first_page":"182","last_page":"199"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12423","display_name":"Software Reliability and Analysis Research","score":0.9950000047683716,"subfield":{"id":"https://openalex.org/subfields/1712","display_name":"Software"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9883000254631042,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.765272855758667},{"id":"https://openalex.org/keywords/kalman-filter","display_name":"Kalman filter","score":0.6634315252304077},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.5848462581634521},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.5336317420005798},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.5113058090209961},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48617857694625854},{"id":"https://openalex.org/keywords/moment","display_name":"Moment (physics)","score":0.4834250211715698},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4746478199958801},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.4587682783603668},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.42724084854125977},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.42572787404060364},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.4193028509616852},{"id":"https://openalex.org/keywords/control-system","display_name":"Control system","score":0.4153788685798645},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3330783545970917},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.31994688510894775},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1124977171421051}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.765272855758667},{"id":"https://openalex.org/C157286648","wikidata":"https://www.wikidata.org/wiki/Q846780","display_name":"Kalman filter","level":2,"score":0.6634315252304077},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5848462581634521},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.5336317420005798},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.5113058090209961},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48617857694625854},{"id":"https://openalex.org/C179254644","wikidata":"https://www.wikidata.org/wiki/Q13222844","display_name":"Moment (physics)","level":2,"score":0.4834250211715698},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4746478199958801},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.4587682783603668},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.42724084854125977},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.42572787404060364},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.4193028509616852},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.4153788685798645},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3330783545970917},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.31994688510894775},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1124977171421051},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/09596518211013169","is_oa":false,"landing_page_url":"https://doi.org/10.1177/09596518211013169","pdf_url":null,"source":{"id":"https://openalex.org/S4210196624","display_name":"Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering","issn_l":"0959-6518","issn":["0959-6518","2041-3041"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W176292746","https://openalex.org/W181283568","https://openalex.org/W1566717537","https://openalex.org/W1581231885","https://openalex.org/W1965988631","https://openalex.org/W1995723008","https://openalex.org/W2008825253","https://openalex.org/W2010378328","https://openalex.org/W2028573862","https://openalex.org/W2043129860","https://openalex.org/W2055873761","https://openalex.org/W2113508851","https://openalex.org/W2147664181","https://openalex.org/W2201689600","https://openalex.org/W2238582461","https://openalex.org/W2283952362","https://openalex.org/W2321066668","https://openalex.org/W2790374560","https://openalex.org/W2959246495","https://openalex.org/W2970528191","https://openalex.org/W2998230219","https://openalex.org/W3006017134","https://openalex.org/W3006988853","https://openalex.org/W3024571879","https://openalex.org/W3110691991","https://openalex.org/W3111326321","https://openalex.org/W3113146371","https://openalex.org/W3146551586","https://openalex.org/W4230800303","https://openalex.org/W4237444302","https://openalex.org/W4245752575","https://openalex.org/W4248979535","https://openalex.org/W4249502605"],"related_works":["https://openalex.org/W2490690736","https://openalex.org/W2080330449","https://openalex.org/W2099333796","https://openalex.org/W2007221537","https://openalex.org/W785766289","https://openalex.org/W1999058329","https://openalex.org/W2156289265","https://openalex.org/W2185997459","https://openalex.org/W2011222276","https://openalex.org/W2349730430"],"abstract_inverted_index":{"In":[0,34,130],"this":[1,90,131],"article,":[2],"we":[3,20,133,211],"study":[4,232],"a":[5,26,31,39,44,97,156,170,229],"new":[6],"approach":[7],"to":[8,67,92,107,140,160,219,235],"predict":[9,108],"failures":[10],"in":[11,17,43,72,169],"feedback":[12,83],"control":[13,23,84,175],"system":[14,24,85,113,192],"and":[15,53,86,261],"particularly":[16],"actuators.":[18],"However,":[19,210],"use":[21,134,212],"two-tank":[22,174],"with":[25],"proportional\u2013integral\u2013derivative":[27],"controller":[28],"for":[29,57,202,243],"controlling":[30],"process":[32,138],"variable.":[33],"practice,":[35],"the":[36,82,109,117,123,135,142,146,149,162,166,191,205,213,221,225,237,240,247,252,256,262],"actuator":[37,257],"is":[38,65,102,120,155,193,233,259,270],"dynamic":[40],"operating":[41],"component":[42],"random":[45],"environment.":[46],"Moreover,":[47],"its":[48,94],"capacity":[49,63,258],"decreases":[50],"over":[51],"time":[52,100],"becomes":[54],"valuable":[55],"information":[56],"reliability":[58,263],"analysis.":[59],"The":[60,195],"loss":[61],"of":[62,81,111,126,145,151,164,173,239,255],"which":[64,119,186,224],"related":[66],"degradation,":[68],"either":[69],"normally":[70],"or":[71,183],"an":[73,180],"accelerated":[74],"manner,":[75],"depends":[76],"on":[77,265],"different":[78],"operational":[79],"conditions":[80],"environmental":[87],"factors.":[88],"For":[89],"reason,":[91],"improve":[93],"working":[95],"condition,":[96],"service":[98],"life":[99,268],"analysis":[101],"necessary.":[103],"Obviously,":[104,246],"one":[105],"has":[106],"trend":[110],"future":[112],"characteristics,":[114],"such":[115],"as":[116],"reliability,":[118],"measured":[121],"by":[122,204],"estimate":[124,220],"value":[125],"remaining":[127,266],"useful":[128,267],"life.":[129],"situation,":[132],"stochastic":[136],"gamma":[137],"model":[139,172],"describe":[141],"degradation":[143,253],"behavior":[144],"actuator.":[147],"Generally,":[148],"algorithm":[150,178,218],"extended":[152],"Kalman":[153],"filter":[154],"widely":[157],"used":[158],"method":[159],"overcome":[161],"difficulties":[163],"estimating":[165],"state":[167],"vector":[168,182],"nonlinear":[171],"system.":[176],"This":[177],"gives":[179],"innovation":[181],"prediction":[184,196],"residual":[185],"contains":[187],"fault":[188],"information,":[189],"when":[190],"failed.":[194],"residuals":[197],"can":[198],"be":[199],"recursively":[200],"computed":[201],"diagnosis":[203],"generalized":[206,214],"likelihood":[207,215],"ratio":[208,216],"test.":[209],"test":[217],"moment":[222],"at":[223],"prognostic":[226],"started.":[227],"Finally,":[228],"practical":[230],"case":[231],"given":[234],"show":[236,250],"effectiveness":[238],"proposed":[241],"approaches":[242],"failure":[244],"detection.":[245],"simulation":[248],"results":[249],"that":[251],"path":[254],"estimated":[260],"based":[264],"predicted":[269],"analyzed.":[271]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":2}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
