{"id":"https://openalex.org/W4405256458","doi":"https://doi.org/10.1177/01423312241287263","title":"Design and experimental validation of fault diagnosis and fault tolerant control in PMSG drives for wind energy conversion systems","display_name":"Design and experimental validation of fault diagnosis and fault tolerant control in PMSG drives for wind energy conversion systems","publication_year":2024,"publication_date":"2024-12-11","ids":{"openalex":"https://openalex.org/W4405256458","doi":"https://doi.org/10.1177/01423312241287263"},"language":"en","primary_location":{"id":"doi:10.1177/01423312241287263","is_oa":false,"landing_page_url":"https://doi.org/10.1177/01423312241287263","pdf_url":null,"source":{"id":"https://openalex.org/S24148485","display_name":"Transactions of the Institute of Measurement and Control","issn_l":"0142-3312","issn":["0142-3312","1477-0369"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Transactions of the Institute of Measurement and Control","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5037460508","display_name":"Hedi Ben Mahdhi","orcid":null},"institutions":[{"id":"https://openalex.org/I108714496","display_name":"Tunis University","ror":"https://ror.org/02q1spa57","country_code":"TN","type":"education","lineage":["https://openalex.org/I108714496"]}],"countries":["TN"],"is_corresponding":true,"raw_author_name":"Hedi Ben Mahdhi","raw_affiliation_strings":["Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)","Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia"],"affiliations":[{"raw_affiliation_string":"Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)","institution_ids":[]},{"raw_affiliation_string":"Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia","institution_ids":["https://openalex.org/I108714496"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5043366255","display_name":"Hechmi Ben Azza","orcid":"https://orcid.org/0000-0003-0519-5540"},"institutions":[{"id":"https://openalex.org/I108714496","display_name":"Tunis University","ror":"https://ror.org/02q1spa57","country_code":"TN","type":"education","lineage":["https://openalex.org/I108714496"]}],"countries":["TN"],"is_corresponding":false,"raw_author_name":"Hechmi Ben Azza","raw_affiliation_strings":["Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)","Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia"],"affiliations":[{"raw_affiliation_string":"Laboratoire de l\u2019Ing\u00e9nierie des Syst\u00e8mes Industriels et des Energies Renouvelables (LISIER)","institution_ids":[]},{"raw_affiliation_string":"Universit\u00e9 de Tunis, Ecole Nationale Sup\u00e9rieure d\u2019Ing\u00e9nieurs de Tunis (ENSIT), Tunis, Tunisia","institution_ids":["https://openalex.org/I108714496"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5037460508"],"corresponding_institution_ids":["https://openalex.org/I108714496"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.20478261,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"48","issue":"4","first_page":"781","last_page":"790"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10361","display_name":"Silicon Carbide Semiconductor Technologies","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.7564828395843506},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.6645966172218323},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.6350314617156982},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5600820779800415},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5549479722976685},{"id":"https://openalex.org/keywords/dspace","display_name":"DSPACE","score":0.5417175889015198},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5124183297157288},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.4629223346710205},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.45880427956581116},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4423828721046448},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.43378257751464844},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.42786872386932373},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.42771488428115845},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.38107311725616455},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.30855536460876465},{"id":"https://openalex.org/keywords/magnet","display_name":"Magnet","score":0.23140400648117065},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.20995590090751648},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11406171321868896},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.07767415046691895}],"concepts":[{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.7564828395843506},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.6645966172218323},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.6350314617156982},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5600820779800415},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5549479722976685},{"id":"https://openalex.org/C38264464","wikidata":"https://www.wikidata.org/wiki/Q1155722","display_name":"DSPACE","level":2,"score":0.5417175889015198},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5124183297157288},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.4629223346710205},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.45880427956581116},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4423828721046448},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.43378257751464844},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.42786872386932373},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.42771488428115845},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38107311725616455},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.30855536460876465},{"id":"https://openalex.org/C16389437","wikidata":"https://www.wikidata.org/wiki/Q11421","display_name":"Magnet","level":2,"score":0.23140400648117065},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.20995590090751648},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11406171321868896},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.07767415046691895},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/01423312241287263","is_oa":false,"landing_page_url":"https://doi.org/10.1177/01423312241287263","pdf_url":null,"source":{"id":"https://openalex.org/S24148485","display_name":"Transactions of the Institute of Measurement and Control","issn_l":"0142-3312","issn":["0142-3312","1477-0369"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Transactions of the Institute of Measurement and Control","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1977010324","https://openalex.org/W1988757962","https://openalex.org/W2001984482","https://openalex.org/W2014526686","https://openalex.org/W2016586238","https://openalex.org/W2025224286","https://openalex.org/W2032232674","https://openalex.org/W2037266811","https://openalex.org/W2059294918","https://openalex.org/W2071760299","https://openalex.org/W2073954532","https://openalex.org/W2076777694","https://openalex.org/W2122552946","https://openalex.org/W2127554258","https://openalex.org/W2129360948","https://openalex.org/W2161703509","https://openalex.org/W2462995574","https://openalex.org/W2516793401","https://openalex.org/W2560197385","https://openalex.org/W2965945084","https://openalex.org/W3151304249","https://openalex.org/W4234850070","https://openalex.org/W4319865463","https://openalex.org/W4393865599"],"related_works":["https://openalex.org/W2623591530","https://openalex.org/W2126606201","https://openalex.org/W2023287903","https://openalex.org/W2382624075","https://openalex.org/W2084742289","https://openalex.org/W2160185143","https://openalex.org/W2381483792","https://openalex.org/W2386113899","https://openalex.org/W2281138998","https://openalex.org/W74330007"],"abstract_inverted_index":{"This":[0],"study":[1],"explores":[2],"a":[3,17,59,72,94,104],"method":[4,38],"for":[5],"detecting":[6],"and":[7,39,68,118,131],"isolating":[8],"faults":[9],"in":[10,56],"wind":[11],"power":[12],"conversion":[13],"systems":[14],"that":[15,51],"use":[16],"permanent":[18],"magnet":[19],"synchronous":[20],"generator":[21],"(PMSG).":[22],"The":[23,42,85,122],"goal":[24],"is":[25,91],"to":[26,79,109,129],"enhance":[27],"the":[28,31,111,114,126],"reliability":[29],"of":[30,58,88,113],"inverter":[32],"by":[33],"implementing":[34],"an":[35,45],"fault":[36,66,116],"detection":[37,67,117],"fault-tolerant":[40],"control.":[41],"converter":[43],"incorporates":[44],"extra":[46],"leg":[47],"with":[48],"two":[49],"switches":[50],"can":[52],"be":[53],"quickly":[54],"connected":[55],"place":[57],"malfunctioning":[60],"leg,":[61],"ensuring":[62],"continued":[63],"operation.":[64],"Our":[65],"isolation":[69,119],"module":[70,90],"employs":[71],"threshold-based":[73],"approach,":[74],"utilizing":[75],"real-time":[76],"signal":[77],"measurements":[78],"identify":[80],"anomalies":[81],"exceeding":[82],"predefined":[83],"limits.":[84],"experimental":[86],"validation":[87],"this":[89],"conducted":[92,108],"on":[93],"high-performance":[95],"dSpace":[96],"DS1104":[97],"controller":[98],"board":[99],"using":[100],"MATLAB":[101],"Simulink.":[102],"Finally,":[103],"real-world":[105],"experiment":[106],"was":[107],"confirm":[110],"effectiveness":[112],"proposed":[115],"(FDI)":[120],"algorithm.":[121],"results":[123],"successfully":[124],"demonstrated":[125],"algorithm\u2019s":[127],"ability":[128],"detect":[130],"isolate":[132],"switch":[133],"faults.":[134]},"counts_by_year":[],"updated_date":"2026-02-17T06:05:46.635709","created_date":"2025-10-10T00:00:00"}
