{"id":"https://openalex.org/W2164641348","doi":"https://doi.org/10.1177/0037549713516516","title":"Modeling, control and electromagnetic transient simulation of the doubly fed induction generator-based wind energy generation system","display_name":"Modeling, control and electromagnetic transient simulation of the doubly fed induction generator-based wind energy generation system","publication_year":2013,"publication_date":"2013-12-20","ids":{"openalex":"https://openalex.org/W2164641348","doi":"https://doi.org/10.1177/0037549713516516","mag":"2164641348"},"language":"en","primary_location":{"id":"doi:10.1177/0037549713516516","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0037549713516516","pdf_url":null,"source":{"id":"https://openalex.org/S32573412","display_name":"SIMULATION","issn_l":"0037-5497","issn":["0037-5497","1741-3133"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SIMULATION","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5114377911","display_name":"Yang Han","orcid":"https://orcid.org/0000-0003-0786-6731"},"institutions":[{"id":"https://openalex.org/I150229711","display_name":"University of Electronic Science and Technology of China","ror":"https://ror.org/04qr3zq92","country_code":"CN","type":"education","lineage":["https://openalex.org/I150229711"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yang Han","raw_affiliation_strings":["Department of Power Electronics, School of Mechanical, Electronic and Industrial Engineering, University of Electronic Science and Technology of China, P. R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Electronics, School of Mechanical, Electronic and Industrial Engineering, University of Electronic Science and Technology of China, P. R. China","institution_ids":["https://openalex.org/I150229711"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007890561","display_name":"Pan Shen","orcid":"https://orcid.org/0000-0002-5483-8824"},"institutions":[{"id":"https://openalex.org/I150229711","display_name":"University of Electronic Science and Technology of China","ror":"https://ror.org/04qr3zq92","country_code":"CN","type":"education","lineage":["https://openalex.org/I150229711"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Pan Shen","raw_affiliation_strings":["Department of Power Electronics, School of Mechanical, Electronic and Industrial Engineering, University of Electronic Science and Technology of China, P. R. China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Power Electronics, School of Mechanical, Electronic and Industrial Engineering, University of Electronic Science and Technology of China, P. R. China","institution_ids":["https://openalex.org/I150229711"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I150229711"],"apc_list":null,"apc_paid":null,"fwci":0.7046,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.761066,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"90","issue":"3","first_page":"275","last_page":"289"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator","display_name":"Stator","score":0.7125284075737},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7004663944244385},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.5974498391151428},{"id":"https://openalex.org/keywords/rotor","display_name":"Rotor (electric)","score":0.5922714471817017},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.5544320344924927},{"id":"https://openalex.org/keywords/emtp","display_name":"Emtp","score":0.5190854072570801},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.48687949776649475},{"id":"https://openalex.org/keywords/reference-frame","display_name":"Reference frame","score":0.47892794013023376},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.4645158350467682},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.4595874845981598},{"id":"https://openalex.org/keywords/maximum-power-point-tracking","display_name":"Maximum power point tracking","score":0.45751187205314636},{"id":"https://openalex.org/keywords/permanent-magnet-synchronous-generator","display_name":"Permanent magnet synchronous generator","score":0.44790762662887573},{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.43074706196784973},{"id":"https://openalex.org/keywords/vector-control","display_name":"Vector control","score":0.41243308782577515},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3978079557418823},{"id":"https://openalex.org/keywords/frame","display_name":"Frame (networking)","score":0.39724859595298767},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3711446523666382},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.27601921558380127},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.26952871680259705},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.2334357500076294},{"id":"https://openalex.org/keywords/induction-motor","display_name":"Induction motor","score":0.18902704119682312},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.14038893580436707},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.1287657618522644},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11268708109855652}],"concepts":[{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.7125284075737},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7004663944244385},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5974498391151428},{"id":"https://openalex.org/C17281054","wikidata":"https://www.wikidata.org/wiki/Q193466","display_name":"Rotor (electric)","level":2,"score":0.5922714471817017},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.5544320344924927},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.5190854072570801},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48687949776649475},{"id":"https://openalex.org/C172849965","wikidata":"https://www.wikidata.org/wiki/Q3148875","display_name":"Reference frame","level":3,"score":0.47892794013023376},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.4645158350467682},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4595874845981598},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.45751187205314636},{"id":"https://openalex.org/C201320609","wikidata":"https://www.wikidata.org/wiki/Q3274420","display_name":"Permanent magnet synchronous generator","level":3,"score":0.44790762662887573},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.43074706196784973},{"id":"https://openalex.org/C152060993","wikidata":"https://www.wikidata.org/wiki/Q1759392","display_name":"Vector control","level":4,"score":0.41243308782577515},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3978079557418823},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.39724859595298767},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3711446523666382},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.27601921558380127},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.26952871680259705},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2334357500076294},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.18902704119682312},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.14038893580436707},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.1287657618522644},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11268708109855652},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1177/0037549713516516","is_oa":false,"landing_page_url":"https://doi.org/10.1177/0037549713516516","pdf_url":null,"source":{"id":"https://openalex.org/S32573412","display_name":"SIMULATION","issn_l":"0037-5497","issn":["0037-5497","1741-3133"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320017","host_organization_name":"SAGE Publishing","host_organization_lineage":["https://openalex.org/P4310320017"],"host_organization_lineage_names":["SAGE Publishing"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SIMULATION","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8899999856948853,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":26,"referenced_works":["https://openalex.org/W1598168251","https://openalex.org/W1797178173","https://openalex.org/W1916075973","https://openalex.org/W1969153859","https://openalex.org/W1981700462","https://openalex.org/W1988455632","https://openalex.org/W2011579856","https://openalex.org/W2013212195","https://openalex.org/W2034773686","https://openalex.org/W2050398607","https://openalex.org/W2050938024","https://openalex.org/W2063826877","https://openalex.org/W2073835617","https://openalex.org/W2096429242","https://openalex.org/W2102014190","https://openalex.org/W2102434591","https://openalex.org/W2103121835","https://openalex.org/W2120098964","https://openalex.org/W2120805805","https://openalex.org/W2130222651","https://openalex.org/W2132514788","https://openalex.org/W2145210779","https://openalex.org/W2164549009","https://openalex.org/W2171688302","https://openalex.org/W4229898014","https://openalex.org/W4255056231"],"related_works":["https://openalex.org/W3046935066","https://openalex.org/W1493078154","https://openalex.org/W1045185228","https://openalex.org/W42884737","https://openalex.org/W3202145633","https://openalex.org/W2006720941","https://openalex.org/W379375666","https://openalex.org/W145546718","https://openalex.org/W2949883251","https://openalex.org/W2071945909"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,7,13,29,34,43,50,55,61,77,88,91,94,102,106,114,118,123,134,143,146,161],"dynamic":[4,26],"modeling":[5],"and":[6,60,69,96,117,152,167],"stator-voltage-aligned":[8],"control":[9,40,59,71,80,147],"(SVAC)":[10],"strategies":[11,41],"of":[12,28,42,93,145],"doubly":[14],"fed":[15],"induction":[16],"generator":[17],"(DFIG)-based":[18],"wind":[19],"energy":[20],"generation":[21,166],"system":[22],"(WEGS).":[23],"The":[24,39,67,82,108,129,149],"state-space":[25],"model":[27,79],"DFIG":[30],"is":[31,85,111,127],"derived":[32],"in":[33,164],"synchronous":[35],"d-q":[36],"reference":[37],"frame.":[38],"DFIG-based":[44],"WEGS":[45],"includes":[46],"three":[47],"parts,":[48],"namely,":[49],"network-side":[51],"converter":[52,57],"(NSC)":[53],"control,":[54],"rotor-side":[56],"(RSC)":[58],"maximum":[62],"power-point":[63],"tracking":[64],"(MPPT)":[65],"algorithm.":[66],"NSC":[68],"RSC":[70],"algorithms":[72],"are":[73,99,139],"implemented":[74],"based":[75],"on":[76],"internal":[78],"principle.":[81],"SVAC":[83],"algorithm":[84],"devised":[86],"for":[87,113,121,160],"RSC,":[89],"where":[90],"positions":[92],"stator":[95],"rotor":[97],"voltage-vectors":[98],"referenced":[100],"to":[101,104],"stator-frame":[103],"simplify":[105],"controller.":[107],"hill-climbing":[109],"method":[110],"adopted":[112],"MPPT":[115],"algorithm,":[116],"iteration":[119],"procedure":[120],"searching":[122],"optimal":[124],"operation":[125],"point":[126],"discussed.":[128],"simulation":[130,155],"results":[131],"obtained":[132],"from":[133],"electromagnetic":[135],"transient":[136],"program":[137],"(EMTP-ATP)":[138],"provided,":[140],"which":[141],"validates":[142],"effectiveness":[144],"algorithms.":[148],"theoretical":[150],"analysis":[151],"EMTP-based":[153],"digital":[154],"can":[156],"be":[157],"widely":[158],"applied":[159],"grid-connected":[162],"converters":[163],"renewable":[165],"smart":[168],"grid":[169],"applications.":[170]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":2}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
