{"id":"https://openalex.org/W2608098969","doi":"https://doi.org/10.1155/2017/2363240","title":"Leveraging Fog Computing for Scalable IoT Datacenter Using Spine-Leaf Network Topology","display_name":"Leveraging Fog Computing for Scalable IoT Datacenter Using Spine-Leaf Network Topology","publication_year":2017,"publication_date":"2017-01-01","ids":{"openalex":"https://openalex.org/W2608098969","doi":"https://doi.org/10.1155/2017/2363240","mag":"2608098969"},"language":"en","primary_location":{"id":"doi:10.1155/2017/2363240","is_oa":true,"landing_page_url":"https://doi.org/10.1155/2017/2363240","pdf_url":"http://downloads.hindawi.com/journals/jece/2017/2363240.pdf","source":{"id":"https://openalex.org/S174662166","display_name":"Journal of Electrical and Computer Engineering","issn_l":"2090-0147","issn":["2090-0147","2090-0155"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319869","host_organization_name":"Hindawi Publishing Corporation","host_organization_lineage":["https://openalex.org/P4310319869"],"host_organization_lineage_names":["Hindawi Publishing Corporation"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Electrical and Computer Engineering","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"http://downloads.hindawi.com/journals/jece/2017/2363240.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077937102","display_name":"Kennedy Chinedu Okafor","orcid":"https://orcid.org/0000-0002-9243-6789"},"institutions":[{"id":"https://openalex.org/I16443873","display_name":"Federal University of Technology Owerri","ror":"https://ror.org/05xzf9508","country_code":"NG","type":"education","lineage":["https://openalex.org/I16443873"]}],"countries":["NG"],"is_corresponding":true,"raw_author_name":"K. C. Okafor","raw_affiliation_strings":["Department of Mechatronics Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria"],"raw_orcid":"https://orcid.org/0000-0002-9243-6789","affiliations":[{"raw_affiliation_string":"Department of Mechatronics Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria","institution_ids":["https://openalex.org/I16443873"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047793716","display_name":"Ifeyinwa E. Achumba","orcid":null},"institutions":[{"id":"https://openalex.org/I16443873","display_name":"Federal University of Technology Owerri","ror":"https://ror.org/05xzf9508","country_code":"NG","type":"education","lineage":["https://openalex.org/I16443873"]}],"countries":["NG"],"is_corresponding":false,"raw_author_name":"Ifeyinwa E. Achumba","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria","institution_ids":["https://openalex.org/I16443873"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108628914","display_name":"Gloria A. Chukwudebe","orcid":"https://orcid.org/0000-0001-9956-5260"},"institutions":[{"id":"https://openalex.org/I16443873","display_name":"Federal University of Technology Owerri","ror":"https://ror.org/05xzf9508","country_code":"NG","type":"education","lineage":["https://openalex.org/I16443873"]}],"countries":["NG"],"is_corresponding":false,"raw_author_name":"Gloria A. Chukwudebe","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria","institution_ids":["https://openalex.org/I16443873"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5039831467","display_name":"G. C. Ononiwu","orcid":"https://orcid.org/0000-0002-0475-6660"},"institutions":[{"id":"https://openalex.org/I16443873","display_name":"Federal University of Technology Owerri","ror":"https://ror.org/05xzf9508","country_code":"NG","type":"education","lineage":["https://openalex.org/I16443873"]}],"countries":["NG"],"is_corresponding":false,"raw_author_name":"Gordon C. Ononiwu","raw_affiliation_strings":["Department of Mechatronics Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechatronics Engineering, Federal University of Technology Owerri, Ihiagwa, Nigeria","institution_ids":["https://openalex.org/I16443873"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5077937102"],"corresponding_institution_ids":["https://openalex.org/I16443873"],"apc_list":{"value":1400,"currency":"USD","value_usd":1400},"apc_paid":{"value":1400,"currency":"USD","value_usd":1400},"fwci":7.2444,"has_fulltext":true,"cited_by_count":94,"citation_normalized_percentile":{"value":0.9737415,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"2017","issue":null,"first_page":"1","last_page":"11"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10273","display_name":"IoT and Edge/Fog Computing","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11478","display_name":"Caching and Content Delivery","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7962627410888672},{"id":"https://openalex.org/keywords/cloud-computing","display_name":"Cloud computing","score":0.7956080436706543},{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.6965916156768799},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.6365997791290283},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.5886811017990112},{"id":"https://openalex.org/keywords/network-topology","display_name":"Network topology","score":0.5191037654876709},{"id":"https://openalex.org/keywords/latency","display_name":"Latency (audio)","score":0.4506049156188965},{"id":"https://openalex.org/keywords/quality-of-service","display_name":"Quality of service","score":0.4491811990737915},{"id":"https://openalex.org/keywords/edge-computing","display_name":"Edge computing","score":0.4428372085094452},{"id":"https://openalex.org/keywords/network-architecture","display_name":"Network architecture","score":0.4427035450935364},{"id":"https://openalex.org/keywords/edge-device","display_name":"Edge device","score":0.4382404386997223},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.42200326919555664},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.41058409214019775},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.10184919834136963},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.09669014811515808}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7962627410888672},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.7956080436706543},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.6965916156768799},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.6365997791290283},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.5886811017990112},{"id":"https://openalex.org/C199845137","wikidata":"https://www.wikidata.org/wiki/Q145490","display_name":"Network topology","level":2,"score":0.5191037654876709},{"id":"https://openalex.org/C82876162","wikidata":"https://www.wikidata.org/wiki/Q17096504","display_name":"Latency (audio)","level":2,"score":0.4506049156188965},{"id":"https://openalex.org/C5119721","wikidata":"https://www.wikidata.org/wiki/Q220501","display_name":"Quality of service","level":2,"score":0.4491811990737915},{"id":"https://openalex.org/C2778456923","wikidata":"https://www.wikidata.org/wiki/Q5337692","display_name":"Edge computing","level":3,"score":0.4428372085094452},{"id":"https://openalex.org/C193415008","wikidata":"https://www.wikidata.org/wiki/Q639681","display_name":"Network architecture","level":2,"score":0.4427035450935364},{"id":"https://openalex.org/C138236772","wikidata":"https://www.wikidata.org/wiki/Q25098575","display_name":"Edge device","level":3,"score":0.4382404386997223},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.42200326919555664},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.41058409214019775},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.10184919834136963},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.09669014811515808}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1155/2017/2363240","is_oa":true,"landing_page_url":"https://doi.org/10.1155/2017/2363240","pdf_url":"http://downloads.hindawi.com/journals/jece/2017/2363240.pdf","source":{"id":"https://openalex.org/S174662166","display_name":"Journal of Electrical and Computer Engineering","issn_l":"2090-0147","issn":["2090-0147","2090-0155"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319869","host_organization_name":"Hindawi Publishing Corporation","host_organization_lineage":["https://openalex.org/P4310319869"],"host_organization_lineage_names":["Hindawi Publishing Corporation"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Electrical and Computer Engineering","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:e58e54138cbb4d579f84f9f09ed2151a","is_oa":true,"landing_page_url":"https://doaj.org/article/e58e54138cbb4d579f84f9f09ed2151a","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Journal of Electrical and Computer Engineering, Vol 2017 (2017)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1155/2017/2363240","is_oa":true,"landing_page_url":"https://doi.org/10.1155/2017/2363240","pdf_url":"http://downloads.hindawi.com/journals/jece/2017/2363240.pdf","source":{"id":"https://openalex.org/S174662166","display_name":"Journal of Electrical and Computer Engineering","issn_l":"2090-0147","issn":["2090-0147","2090-0155"],"is_oa":true,"is_in_doaj":true,"is_core":true,"host_organization":"https://openalex.org/P4310319869","host_organization_name":"Hindawi Publishing Corporation","host_organization_lineage":["https://openalex.org/P4310319869"],"host_organization_lineage_names":["Hindawi Publishing Corporation"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Electrical and Computer Engineering","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320326202","display_name":"University Of Nigeria Nsukka","ror":"https://ror.org/01sn1yx84"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2608098969.pdf","grobid_xml":"https://content.openalex.org/works/W2608098969.grobid-xml"},"referenced_works_count":4,"referenced_works":["https://openalex.org/W1998152936","https://openalex.org/W2045287414","https://openalex.org/W2077107182","https://openalex.org/W2077185719"],"related_works":["https://openalex.org/W4322761281","https://openalex.org/W4238233472","https://openalex.org/W3111395152","https://openalex.org/W4313526662","https://openalex.org/W4313463218","https://openalex.org/W3106131444","https://openalex.org/W3216099748","https://openalex.org/W4205963435","https://openalex.org/W4312996489","https://openalex.org/W3214037210"],"abstract_inverted_index":{"With":[0],"the":[1,31,36,42,134,140],"Internet":[2],"of":[3],"Everything":[4],"(IoE)":[5],"paradigm":[6],"that":[7,71],"gathers":[8],"almost":[9],"every":[10],"object":[11],"online,":[12],"huge":[13],"traffic":[14],"workload,":[15],"bandwidth,":[16],"security,":[17],"and":[18,59,114,126,159,167,184],"latency":[19,158],"issues":[20,162],"remain":[21],"a":[22,87,93,106,148,164],"concern":[23],"for":[24,48,156],"IoT":[25,38,69,170],"users":[26],"in":[27,35,120,163,188],"today\u2019s":[28],"world.":[29],"Besides,":[30],"scalability":[32],"requirements":[33],"found":[34],"current":[37],"data":[39,83,132],"processing":[40],"(in":[41],"cloud)":[43],"can":[44,130],"hardly":[45],"be":[46],"used":[47],"applications":[49,129],"such":[50],"as":[51,177],"assisted":[52],"living":[53],"systems,":[54],"Big":[55],"Data":[56],"analytic":[57],"solutions,":[58],"smart":[60],"embedded":[61],"applications.":[62,191],"This":[63,102,173],"paper":[64,122],"proposes":[65],"an":[66],"extended":[67],"cloud":[68,88,135],"model":[70],"optimizes":[72],"bandwidth":[73,127,180],"while":[74,181],"allowing":[75],"edge":[76,141],"devices":[77],"(Internet-connected":[78],"objects/devices)":[79],"to":[80,133,139],"smartly":[81],"process":[82],"without":[84,143],"relying":[85],"on":[86],"network.":[89],"Its":[90],"integration":[91],"with":[92,105],"massively":[94],"scaled":[95],"spine-leaf":[96,149],"(SL)":[97],"network":[98,112,152,160],"topology":[99],"is":[100,103,154,175],"highlighted.":[101],"contrasted":[104],"legacy":[107],"multitier":[108],"layered":[109],"architecture":[110],"housing":[111],"services":[113],"routing":[115],"policies.":[116],"The":[117],"perspective":[118],"offered":[119],"this":[121],"explains":[123],"how":[124],"low-latency":[125],"intensive":[128],"transfer":[131],"(and":[136],"then":[137],"back":[138],"application)":[142],"impacting":[144],"QoS":[145],"performance.":[146],"Consequently,":[147],"Fog":[150],"computing":[151],"(SL-FCN)":[153],"presented":[155],"reducing":[157],"congestion":[161],"highly":[165],"distributed":[166],"multilayer":[168],"virtualized":[169],"datacenter":[171],"environment.":[172],"approach":[174],"cost-effective":[176],"it":[178],"maximizes":[179],"maintaining":[182],"redundancy":[183],"resiliency":[185],"against":[186],"failures":[187],"mission":[189],"critical":[190]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":7},{"year":2023,"cited_by_count":15},{"year":2022,"cited_by_count":17},{"year":2021,"cited_by_count":18},{"year":2020,"cited_by_count":10},{"year":2019,"cited_by_count":9},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":7}],"updated_date":"2026-05-21T09:19:25.381259","created_date":"2025-10-10T00:00:00"}
