{"id":"https://openalex.org/W2016924415","doi":"https://doi.org/10.1147/rd.464.0503","title":"RAS design for the IBM eServer z900","display_name":"RAS design for the IBM eServer z900","publication_year":2002,"publication_date":"2002-07-01","ids":{"openalex":"https://openalex.org/W2016924415","doi":"https://doi.org/10.1147/rd.464.0503","mag":"2016924415"},"language":"en","primary_location":{"id":"doi:10.1147/rd.464.0503","is_oa":false,"landing_page_url":"https://doi.org/10.1147/rd.464.0503","pdf_url":null,"source":{"id":"https://openalex.org/S4210219925","display_name":"IBM Journal of Research and Development","issn_l":"0018-8646","issn":["0018-8646","2151-8556"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320652","host_organization_name":"IBM","host_organization_lineage":["https://openalex.org/P4310320652"],"host_organization_lineage_names":["IBM"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IBM Journal of Research and Development","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5031945971","display_name":"L. C. Alves","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"L. C. Alves","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037558763","display_name":"M. L. Fair","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"M. L. Fair","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040105695","display_name":"P. J. Meaney","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"P. J. Meaney","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073185787","display_name":"C. L. Chen","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"C. L. Chen","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109874296","display_name":"William Clarke","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"W. J. Clarke","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005162305","display_name":"G. C. Wellwood","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"G. C. Wellwood","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018954678","display_name":"Nico Weber","orcid":"https://orcid.org/0000-0002-6753-6104"},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"N. E. Weber","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044710464","display_name":"I. N. Modi","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210091433","display_name":"Poughkeepsie Public Library District","ror":"https://ror.org/001vaag74","country_code":"US","type":"archive","lineage":["https://openalex.org/I4210091433"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"I. N. Modi","raw_affiliation_strings":["IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","IBM eServer Group, Poughkeepsie, New York#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, 2455 South Road, Poughkeepsie, New York 12601, USA","institution_ids":["https://openalex.org/I4210091433"]},{"raw_affiliation_string":"IBM eServer Group, Poughkeepsie, New York#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082995126","display_name":"B. K. Tolan","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210140601","display_name":"Taymyr Nature Reserve","ror":"https://ror.org/03r1tnz13","country_code":"RU","type":"archive","lineage":["https://openalex.org/I4210140601"]}],"countries":["RU","US"],"is_corresponding":false,"raw_author_name":"B. K. Tolan","raw_affiliation_strings":["IBM eServer Group, Schoenaicherstrasse 220, 71032 Boeblingen, Germany","IBM eServer Group, Boeblingen, Germany#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, Schoenaicherstrasse 220, 71032 Boeblingen, Germany","institution_ids":["https://openalex.org/I4210140601"]},{"raw_affiliation_string":"IBM eServer Group, Boeblingen, Germany#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034214347","display_name":"F. Freier","orcid":null},"institutions":[{"id":"https://openalex.org/I1341412227","display_name":"IBM (United States)","ror":"https://ror.org/05hh8d621","country_code":"US","type":"company","lineage":["https://openalex.org/I1341412227"]},{"id":"https://openalex.org/I4210140601","display_name":"Taymyr Nature Reserve","ror":"https://ror.org/03r1tnz13","country_code":"RU","type":"archive","lineage":["https://openalex.org/I4210140601"]}],"countries":["RU","US"],"is_corresponding":false,"raw_author_name":"F. Freier","raw_affiliation_strings":["IBM eServer Group, Schoenaicherstrasse 220, 71032 Boeblingen, Germany","IBM eServer Group, Boeblingen, Germany#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IBM eServer Group, Schoenaicherstrasse 220, 71032 Boeblingen, Germany","institution_ids":["https://openalex.org/I4210140601"]},{"raw_affiliation_string":"IBM eServer Group, Boeblingen, Germany#TAB#","institution_ids":["https://openalex.org/I1341412227"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0601,"has_fulltext":false,"cited_by_count":18,"citation_normalized_percentile":{"value":0.86572989,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":"46","issue":"4.5","first_page":"503","last_page":"521"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11005","display_name":"Radiation Effects in Electronics","score":0.9962000250816345,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10772","display_name":"Distributed systems and fault tolerance","score":0.9679999947547913,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11032","display_name":"VLSI and Analog Circuit Testing","score":0.96670001745224,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ibm","display_name":"IBM","score":0.8613792657852173},{"id":"https://openalex.org/keywords/serviceability","display_name":"Serviceability (structure)","score":0.7797794342041016},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5567010641098022},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.43920210003852844},{"id":"https://openalex.org/keywords/perspective","display_name":"Perspective (graphical)","score":0.4287710189819336},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.38211894035339355},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.3357265591621399},{"id":"https://openalex.org/keywords/engineering-management","display_name":"Engineering management","score":0.3208616375923157},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31044280529022217},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.06753945350646973}],"concepts":[{"id":"https://openalex.org/C70388272","wikidata":"https://www.wikidata.org/wiki/Q5968558","display_name":"IBM","level":2,"score":0.8613792657852173},{"id":"https://openalex.org/C110245778","wikidata":"https://www.wikidata.org/wiki/Q2169658","display_name":"Serviceability (structure)","level":2,"score":0.7797794342041016},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5567010641098022},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.43920210003852844},{"id":"https://openalex.org/C12713177","wikidata":"https://www.wikidata.org/wiki/Q1900281","display_name":"Perspective (graphical)","level":2,"score":0.4287710189819336},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.38211894035339355},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.3357265591621399},{"id":"https://openalex.org/C110354214","wikidata":"https://www.wikidata.org/wiki/Q6314146","display_name":"Engineering management","level":1,"score":0.3208616375923157},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31044280529022217},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.06753945350646973},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1147/rd.464.0503","is_oa":false,"landing_page_url":"https://doi.org/10.1147/rd.464.0503","pdf_url":null,"source":{"id":"https://openalex.org/S4210219925","display_name":"IBM Journal of Research and Development","issn_l":"0018-8646","issn":["0018-8646","2151-8556"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310320652","host_organization_name":"IBM","host_organization_lineage":["https://openalex.org/P4310320652"],"host_organization_lineage_names":["IBM"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IBM Journal of Research and Development","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.49000000953674316,"display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W1907820776","https://openalex.org/W1972629367","https://openalex.org/W1982791107","https://openalex.org/W2000859879","https://openalex.org/W2043345718","https://openalex.org/W2057022746","https://openalex.org/W2065440049","https://openalex.org/W2069402650","https://openalex.org/W2088250010","https://openalex.org/W2113705430","https://openalex.org/W2149445045"],"related_works":["https://openalex.org/W2748952813","https://openalex.org/W2370611442","https://openalex.org/W3151946113","https://openalex.org/W2097451945","https://openalex.org/W4234058849","https://openalex.org/W75531337","https://openalex.org/W2398322655","https://openalex.org/W2524838473","https://openalex.org/W3081879387","https://openalex.org/W628040712"],"abstract_inverted_index":{"The":[0,41],"IBM":[1,90],"eServer":[2,29,42],"zSeries\u2122":[3],"Model":[4],"900,":[5],"or":[6],"z900,":[7],"has":[8,96],"been":[9],"designed":[10],"with":[11,76],"major":[12],"enhancements":[13,110],"for":[14,73,88,101,124],"hardware":[15],"reliability,":[16],"availability,":[17],"and":[18,32,53,59,62,71,92,111,120],"serviceability":[19],"(RAS)":[20],"in":[21,66],"support":[22],"of":[23,37,69],"the":[24,28,33,46,67,81,84,89,94,107,115],"zSeries":[25,95],"RAS":[26,82,86,109,116],"strategy,":[27],"self-management":[30,43],"technologies,":[31],"z900":[34,108],"design":[35],"objective":[36],"continuous":[38],"reliable":[39],"operation.":[40],"technologies":[44],"enable":[45],"server":[47],"to":[48,51,57,63],"protect":[49],"itself,":[50,61,65],"detect":[52],"recover":[54],"from":[55],"errors,":[56],"change":[58],"configure":[60],"optimize":[64],"presence":[68],"problems":[70],"changes,":[72],"maximum":[74],"performance":[75],"minimum":[77],"outside":[78],"intervention.":[79],"From":[80],"perspective,":[83],"longstanding":[85],"strategy":[87,117],"S/390\u00ae":[91],"now":[93],"provided":[97],"an":[98],"excellent":[99],"foundation":[100],"self":[102],"management.":[103],"This":[104],"paper":[105],"describes":[106],"how":[112],"they":[113],"strengthen":[114],"building":[118],"blocks":[119],"provide":[121],"a":[122],"basis":[123],"autonomic":[125],"computing.":[126]},"counts_by_year":[{"year":2015,"cited_by_count":2},{"year":2012,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
