{"id":"https://openalex.org/W2295592676","doi":"https://doi.org/10.1145/2821650.2830301","title":"Poster Abstract","display_name":"Poster Abstract","publication_year":2015,"publication_date":"2015-11-03","ids":{"openalex":"https://openalex.org/W2295592676","doi":"https://doi.org/10.1145/2821650.2830301","mag":"2295592676"},"language":"en","primary_location":{"id":"doi:10.1145/2821650.2830301","is_oa":false,"landing_page_url":"https://doi.org/10.1145/2821650.2830301","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2nd ACM International Conference on Embedded Systems for Energy-Efficient Built Environments","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075533868","display_name":"Afreen Ferdoash","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Afreen Ferdoash","raw_affiliation_strings":["Zenatix Solutions Pvt. Ltd., Delhi, India"],"affiliations":[{"raw_affiliation_string":"Zenatix Solutions Pvt. Ltd., Delhi, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020573379","display_name":"Shubham Saini","orcid":"https://orcid.org/0000-0003-2541-6267"},"institutions":[{"id":"https://openalex.org/I119939252","display_name":"Indraprastha Institute of Information Technology Delhi","ror":"https://ror.org/03vfp4g33","country_code":"IN","type":"education","lineage":["https://openalex.org/I119939252"]},{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shubham Saini","raw_affiliation_strings":["IIIT Delhi, Delhi, India"],"affiliations":[{"raw_affiliation_string":"IIIT Delhi, Delhi, India","institution_ids":["https://openalex.org/I119939252","https://openalex.org/I68891433"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045022465","display_name":"Jitesh Khurana","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jitesh Khurana","raw_affiliation_strings":["Zenatix Solutions Pvt. Ltd., Delhi, India"],"affiliations":[{"raw_affiliation_string":"Zenatix Solutions Pvt. Ltd., Delhi, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082832074","display_name":"Amarjeet Singh","orcid":"https://orcid.org/0000-0003-0978-0907"},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]},{"id":"https://openalex.org/I119939252","display_name":"Indraprastha Institute of Information Technology Delhi","ror":"https://ror.org/03vfp4g33","country_code":"IN","type":"education","lineage":["https://openalex.org/I119939252"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Amarjeet Singh","raw_affiliation_strings":["IIIT Delhi &amp; Zenatix Solutions Pvt. Ltd., Delhi, India"],"affiliations":[{"raw_affiliation_string":"IIIT Delhi &amp; Zenatix Solutions Pvt. Ltd., Delhi, India","institution_ids":["https://openalex.org/I68891433","https://openalex.org/I119939252"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5075533868"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.14271817,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"107","last_page":"108"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9589999914169312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9589999914169312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9435999989509583,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9831969738006592},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.6692829132080078},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6252231597900391},{"id":"https://openalex.org/keywords/chiller","display_name":"Chiller","score":0.6089842915534973},{"id":"https://openalex.org/keywords/rule-of-thumb","display_name":"Rule of thumb","score":0.5181114077568054},{"id":"https://openalex.org/keywords/scale","display_name":"Scale (ratio)","score":0.48965150117874146},{"id":"https://openalex.org/keywords/ventilation","display_name":"Ventilation (architecture)","score":0.4749434292316437},{"id":"https://openalex.org/keywords/water-chiller","display_name":"Water chiller","score":0.46915948390960693},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4501500129699707},{"id":"https://openalex.org/keywords/ashrae-90.1","display_name":"ASHRAE 90.1","score":0.4198853373527527},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.3808104395866394},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3532586693763733},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.3288743495941162},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.26206889748573303},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1197090744972229},{"id":"https://openalex.org/keywords/gas-compressor","display_name":"Gas compressor","score":0.09921327233314514}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9831969738006592},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.6692829132080078},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6252231597900391},{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.6089842915534973},{"id":"https://openalex.org/C89246107","wikidata":"https://www.wikidata.org/wiki/Q1398821","display_name":"Rule of thumb","level":2,"score":0.5181114077568054},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.48965150117874146},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.4749434292316437},{"id":"https://openalex.org/C182254935","wikidata":"https://www.wikidata.org/wiki/Q1722733","display_name":"Water chiller","level":4,"score":0.46915948390960693},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4501500129699707},{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.4198853373527527},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3808104395866394},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3532586693763733},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.3288743495941162},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26206889748573303},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1197090744972229},{"id":"https://openalex.org/C131097465","wikidata":"https://www.wikidata.org/wiki/Q178898","display_name":"Gas compressor","level":2,"score":0.09921327233314514},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/2821650.2830301","is_oa":false,"landing_page_url":"https://doi.org/10.1145/2821650.2830301","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2nd ACM International Conference on Embedded Systems for Energy-Efficient Built Environments","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8999999761581421,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W2012072009"],"related_works":["https://openalex.org/W4200275401","https://openalex.org/W2084082636","https://openalex.org/W4382776012","https://openalex.org/W2953782904","https://openalex.org/W2075262650","https://openalex.org/W2262341899","https://openalex.org/W2333766344","https://openalex.org/W2373084361","https://openalex.org/W3168899032","https://openalex.org/W2019903672"],"abstract_inverted_index":{"Heating,":[0],"Ventilation":[1],"and":[2,38,115],"Air":[3],"Conditioning":[4],"(HVAC)":[5],"systems":[6],"are":[7,69],"one":[8],"of":[9,13,22,34,36,147],"the":[10,46,63,66,110,121,145,154,159],"biggest":[11],"consumers":[12],"energy":[14,24,133,155],"within":[15],"commercial":[16],"buildings,":[17],"contributing":[18],"to":[19,43,60,86,112,130,143],"over":[20],"40%":[21],"their":[23],"usage.":[25],"A":[26],"large":[27,77,125],"scale":[28,78,126],"Building":[29],"Management":[30],"System":[31],"(BMS)":[32],"comprising":[33],"hundreds":[35],"sensors":[37],"actuators":[39],"is":[40,83],"commonly":[41],"used":[42],"appropriately":[44],"manage":[45],"HVAC":[47,107,122,160],"operations":[48],"in":[49,65,120,141,152],"a":[50],"facility.":[51],"Such":[52],"BMS":[53,82,127],"require":[54],"manual":[55],"set":[56],"points":[57],"(e.g.":[58],"time":[59,105],"switch":[61],"on":[62],"chillers":[64],"morning)":[67],"which":[68],"often":[70],"driven":[71],"by":[72,81],"some":[73],"thumb":[74],"rules.":[75],"Further,":[76],"data":[79,128,137],"generated":[80],"rarely":[84],"analyzed":[85],"identify":[87],"opportunities":[88,131],"for":[89,106,108,132],"operational":[90],"savings.":[91,134],"In":[92],"this":[93],"paper":[94],"we":[95],"take":[96],"two":[97,139],"specific":[98],"use":[99,136],"cases":[100],"-":[101],"1.":[102],"Optimal":[103],"start":[104],"pre-cooling":[109],"buildings":[111,140],"desired":[113],"temperature;":[114],"2.":[116],"Identifying":[117],"excessive":[118],"air-flow":[119],"system":[123],"using":[124,148],"leading":[129],"We":[135],"from":[138,158],"India":[142],"demonstrate":[144],"effectiveness":[146],"such":[149],"simple":[150],"analytics":[151],"identifying":[153],"saving":[156],"potential":[157],"system.":[161]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2016-06-24T00:00:00"}
