{"id":"https://openalex.org/W2088725190","doi":"https://doi.org/10.1145/2093698.2093830","title":"Increased volume coverage in 3D magnetic particle imaging","display_name":"Increased volume coverage in 3D magnetic particle imaging","publication_year":2011,"publication_date":"2011-10-26","ids":{"openalex":"https://openalex.org/W2088725190","doi":"https://doi.org/10.1145/2093698.2093830","mag":"2088725190"},"language":"en","primary_location":{"id":"doi:10.1145/2093698.2093830","is_oa":false,"landing_page_url":"https://doi.org/10.1145/2093698.2093830","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091764031","display_name":"J\u00fcrgen Rahmer","orcid":"https://orcid.org/0000-0001-8514-4801"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"J. Rahmer","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103088243","display_name":"Bernhard Gleich","orcid":"https://orcid.org/0000-0002-1162-5327"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"B. Gleich","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024544045","display_name":"J. Schmidt","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J. Schmidt","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056536542","display_name":"Ingo Schmale","orcid":"https://orcid.org/0000-0003-1081-0085"},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"I. Schmale","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038091760","display_name":"Claas Bontus","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"C. Bontus","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024948841","display_name":"J. Kanzenbach","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J. Kanzenbach","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5111708438","display_name":"J. Borgert","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J. Borgert","raw_affiliation_strings":["Philips Technologie GmbH Research Laboratories, Hamburg, Germany","Philips Technologie GmbH, Research Laboratories, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Technologie GmbH Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]},{"raw_affiliation_string":"Philips Technologie GmbH, Research Laboratories, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055558297","display_name":"O. Woywode","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162505","display_name":"Philips (Germany)","ror":"https://ror.org/05san5604","country_code":"DE","type":"company","lineage":["https://openalex.org/I4210122849","https://openalex.org/I4210162505"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"O. Woywode","raw_affiliation_strings":["Philips Medical Systems DMC GmbH, Hamburg, Germany"],"affiliations":[{"raw_affiliation_string":"Philips Medical Systems DMC GmbH, Hamburg, Germany","institution_ids":["https://openalex.org/I4210162505"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109202995","display_name":"J. Weizenecker","orcid":null},"institutions":[{"id":"https://openalex.org/I70886390","display_name":"Karlsruhe University of Applied Sciences","ror":"https://ror.org/01c0m1t63","country_code":"DE","type":"education","lineage":["https://openalex.org/I70886390"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J. Weizenecker","raw_affiliation_strings":["University of Applied Sciences, Karlsruhe, Germany"],"affiliations":[{"raw_affiliation_string":"University of Applied Sciences, Karlsruhe, Germany","institution_ids":["https://openalex.org/I70886390"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":9,"corresponding_author_ids":["https://openalex.org/A5091764031"],"corresponding_institution_ids":["https://openalex.org/I4210162505"],"apc_list":null,"apc_paid":null,"fwci":0.2098,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.58499726,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12405","display_name":"Characterization and Applications of Magnetic Nanoparticles","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12405","display_name":"Characterization and Applications of Magnetic Nanoparticles","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11786","display_name":"Geomagnetism and Paleomagnetism Studies","score":0.998199999332428,"subfield":{"id":"https://openalex.org/subfields/1312","display_name":"Molecular Biology"},"field":{"id":"https://openalex.org/fields/13","display_name":"Biochemistry, Genetics and Molecular Biology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T11255","display_name":"Microfluidic and Bio-sensing Technologies","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnetic-particle-imaging","display_name":"Magnetic particle imaging","score":0.9627015590667725},{"id":"https://openalex.org/keywords/volume","display_name":"Volume (thermodynamics)","score":0.6747404932975769},{"id":"https://openalex.org/keywords/molecular-imaging","display_name":"Molecular imaging","score":0.5437402129173279},{"id":"https://openalex.org/keywords/particle","display_name":"Particle (ecology)","score":0.4988522529602051},{"id":"https://openalex.org/keywords/tomographic-reconstruction","display_name":"Tomographic reconstruction","score":0.47827088832855225},{"id":"https://openalex.org/keywords/magnetic-particle-inspection","display_name":"Magnetic particle inspection","score":0.4767778217792511},{"id":"https://openalex.org/keywords/medical-imaging","display_name":"Medical imaging","score":0.47598567605018616},{"id":"https://openalex.org/keywords/magnetization","display_name":"Magnetization","score":0.4373975098133087},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.4336380660533905},{"id":"https://openalex.org/keywords/scaling","display_name":"Scaling","score":0.41825804114341736},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.37398678064346313},{"id":"https://openalex.org/keywords/magnetic-nanoparticles","display_name":"Magnetic nanoparticles","score":0.36407649517059326},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.36190128326416016},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3341484069824219},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.30733710527420044},{"id":"https://openalex.org/keywords/tomography","display_name":"Tomography","score":0.26689231395721436},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.2658592462539673},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.2511866092681885},{"id":"https://openalex.org/keywords/nanotechnology","display_name":"Nanotechnology","score":0.14903831481933594},{"id":"https://openalex.org/keywords/in-vivo","display_name":"In vivo","score":0.13424330949783325},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.12289637327194214},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.11921742558479309},{"id":"https://openalex.org/keywords/nanoparticle","display_name":"Nanoparticle","score":0.11776497960090637},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.10116243362426758}],"concepts":[{"id":"https://openalex.org/C140722275","wikidata":"https://www.wikidata.org/wiki/Q1884331","display_name":"Magnetic particle imaging","level":4,"score":0.9627015590667725},{"id":"https://openalex.org/C20556612","wikidata":"https://www.wikidata.org/wiki/Q4469374","display_name":"Volume (thermodynamics)","level":2,"score":0.6747404932975769},{"id":"https://openalex.org/C136339569","wikidata":"https://www.wikidata.org/wiki/Q1142297","display_name":"Molecular imaging","level":3,"score":0.5437402129173279},{"id":"https://openalex.org/C2778517922","wikidata":"https://www.wikidata.org/wiki/Q7140482","display_name":"Particle (ecology)","level":2,"score":0.4988522529602051},{"id":"https://openalex.org/C97742081","wikidata":"https://www.wikidata.org/wiki/Q7820109","display_name":"Tomographic reconstruction","level":3,"score":0.47827088832855225},{"id":"https://openalex.org/C109647046","wikidata":"https://www.wikidata.org/wiki/Q1884449","display_name":"Magnetic particle inspection","level":4,"score":0.4767778217792511},{"id":"https://openalex.org/C31601959","wikidata":"https://www.wikidata.org/wiki/Q931309","display_name":"Medical imaging","level":2,"score":0.47598567605018616},{"id":"https://openalex.org/C32546565","wikidata":"https://www.wikidata.org/wiki/Q856711","display_name":"Magnetization","level":3,"score":0.4373975098133087},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.4336380660533905},{"id":"https://openalex.org/C99844830","wikidata":"https://www.wikidata.org/wiki/Q102441924","display_name":"Scaling","level":2,"score":0.41825804114341736},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.37398678064346313},{"id":"https://openalex.org/C87023908","wikidata":"https://www.wikidata.org/wiki/Q3870166","display_name":"Magnetic nanoparticles","level":3,"score":0.36407649517059326},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.36190128326416016},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3341484069824219},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.30733710527420044},{"id":"https://openalex.org/C163716698","wikidata":"https://www.wikidata.org/wiki/Q841267","display_name":"Tomography","level":2,"score":0.26689231395721436},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.2658592462539673},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.2511866092681885},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.14903831481933594},{"id":"https://openalex.org/C207001950","wikidata":"https://www.wikidata.org/wiki/Q141124","display_name":"In vivo","level":2,"score":0.13424330949783325},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.12289637327194214},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.11921742558479309},{"id":"https://openalex.org/C155672457","wikidata":"https://www.wikidata.org/wiki/Q61231","display_name":"Nanoparticle","level":2,"score":0.11776497960090637},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.10116243362426758},{"id":"https://openalex.org/C111368507","wikidata":"https://www.wikidata.org/wiki/Q43518","display_name":"Oceanography","level":1,"score":0.0},{"id":"https://openalex.org/C150903083","wikidata":"https://www.wikidata.org/wiki/Q7108","display_name":"Biotechnology","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/2093698.2093830","is_oa":false,"landing_page_url":"https://doi.org/10.1145/2093698.2093830","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G5650671485","display_name":null,"funder_award_id":"FKZ 13N9079","funder_id":"https://openalex.org/F4320321114","funder_display_name":"Bundesministerium f\u00fcr Bildung und Forschung"}],"funders":[{"id":"https://openalex.org/F4320321114","display_name":"Bundesministerium f\u00fcr Bildung und Forschung","ror":"https://ror.org/04pz7b180"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1977575775","https://openalex.org/W1983277479","https://openalex.org/W2031852422","https://openalex.org/W2033750573","https://openalex.org/W2040285835","https://openalex.org/W2049863502","https://openalex.org/W2058917901","https://openalex.org/W2085219964","https://openalex.org/W2089882340","https://openalex.org/W2115091041","https://openalex.org/W2128555254","https://openalex.org/W2151752675","https://openalex.org/W2166257486","https://openalex.org/W2409163903","https://openalex.org/W6714572923"],"related_works":["https://openalex.org/W4239310695","https://openalex.org/W2091017237","https://openalex.org/W1553668270","https://openalex.org/W3165454691","https://openalex.org/W2112281092","https://openalex.org/W2015976998","https://openalex.org/W2074714886","https://openalex.org/W4319778263","https://openalex.org/W2002220930","https://openalex.org/W1557662260"],"abstract_inverted_index":{"Magnetic":[0],"particle":[1,85],"imaging":[2,8,32,48,55,73,95],"(MPI)":[3],"is":[4],"a":[5,58],"new":[6],"tomographic":[7],"approach":[9,99],"that":[10],"detects":[11],"and":[12,29,87,97],"localizes":[13],"magnetic":[14],"nano-particles":[15],"by":[16],"their":[17],"non-linear":[18],"magnetization":[19],"response":[20],"to":[21,76,93,100],"externally":[22],"applied":[23],"fields.":[24],"MPI":[25],"allows":[26],"quantitative,":[27],"sensitive,":[28],"rapid":[30],"volumetric":[31],"of":[33,35,49,63,84],"distributions":[34],"particles":[36],"injected":[37],"into":[38],"the":[39,66,72,82,94],"blood":[40],"stream.":[41],"Initial":[42],"experiments":[43],"showing":[44],"3D":[45],"real-time":[46],"in-vivo":[47],"mice":[50],"were":[51],"conducted":[52],"using":[53],"small":[54],"volumes":[56],"covering":[57],"single":[59],"organ.":[60],"In":[61],"view":[62],"scaling":[64],"up":[65],"hardware":[67],"for":[68],"future":[69],"clinical":[70],"imaging,":[71],"volume":[74,108],"has":[75],"be":[77],"increased.":[78],"This":[79],"contribution":[80],"describes":[81],"basics":[83],"detection":[86],"spatial":[88],"encoding":[89],"in":[90],"MPI,":[91],"limitations":[92],"volume,":[96],"one":[98],"circumvent":[101],"these":[102],"limitations.":[103],"Experimental":[104],"results":[105],"with":[106],"increased":[107],"coverage":[109],"are":[110],"presented.":[111]},"counts_by_year":[{"year":2013,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
