{"id":"https://openalex.org/W7117447749","doi":"https://doi.org/10.1145/3714394.3756170","title":"Development of a PPG Sensor Mounting Position Adjustment Device","display_name":"Development of a PPG Sensor Mounting Position Adjustment Device","publication_year":2025,"publication_date":"2025-10-12","ids":{"openalex":"https://openalex.org/W7117447749","doi":"https://doi.org/10.1145/3714394.3756170"},"language":null,"primary_location":{"id":"doi:10.1145/3714394.3756170","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3714394.3756170","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Companion of the 2025 ACM International Joint Conference on Pervasive and Ubiquitous Computing","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003520849","display_name":"Atsuhiro Fujii","orcid":"https://orcid.org/0000-0002-9292-2912"},"institutions":[{"id":"https://openalex.org/I135768898","display_name":"Ritsumeikan University","ror":"https://ror.org/0197nmd03","country_code":"JP","type":"education","lineage":["https://openalex.org/I135768898","https://openalex.org/I4390039241"]}],"countries":["JP"],"is_corresponding":true,"raw_author_name":"Atsuhiro Fujii","raw_affiliation_strings":["Ritsumeikan University, Osaka, Japan"],"affiliations":[{"raw_affiliation_string":"Ritsumeikan University, Osaka, Japan","institution_ids":["https://openalex.org/I135768898"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057692201","display_name":"Kazuya Murao","orcid":null},"institutions":[{"id":"https://openalex.org/I135768898","display_name":"Ritsumeikan University","ror":"https://ror.org/0197nmd03","country_code":"JP","type":"education","lineage":["https://openalex.org/I135768898","https://openalex.org/I4390039241"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Kazuya Murao","raw_affiliation_strings":["Ritsumeikan University, Osaka, Japan"],"affiliations":[{"raw_affiliation_string":"Ritsumeikan University, Osaka, Japan","institution_ids":["https://openalex.org/I135768898"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5003520849"],"corresponding_institution_ids":["https://openalex.org/I135768898"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.58757801,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"741","last_page":"744"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9904000163078308,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11670","display_name":"Pressure Ulcer Prevention and Management","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/3609","display_name":"Occupational Therapy"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10338","display_name":"Advanced Sensor and Energy Harvesting Materials","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.8842999935150146},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.6579999923706055},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.6018999814987183},{"id":"https://openalex.org/keywords/position-sensor","display_name":"Position sensor","score":0.5982999801635742},{"id":"https://openalex.org/keywords/position","display_name":"Position (finance)","score":0.5376999974250793},{"id":"https://openalex.org/keywords/pulse-wave","display_name":"Pulse wave","score":0.38280001282691956},{"id":"https://openalex.org/keywords/measurement-device","display_name":"Measurement device","score":0.3273000121116638}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.8842999935150146},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.6579999923706055},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.6018999814987183},{"id":"https://openalex.org/C29258643","wikidata":"https://www.wikidata.org/wiki/Q2937669","display_name":"Position sensor","level":3,"score":0.5982999801635742},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5501000285148621},{"id":"https://openalex.org/C198082294","wikidata":"https://www.wikidata.org/wiki/Q3399648","display_name":"Position (finance)","level":2,"score":0.5376999974250793},{"id":"https://openalex.org/C172321821","wikidata":"https://www.wikidata.org/wiki/Q7259685","display_name":"Pulse wave","level":3,"score":0.38280001282691956},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.36079999804496765},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.33640000224113464},{"id":"https://openalex.org/C3019950295","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measurement device","level":2,"score":0.3273000121116638},{"id":"https://openalex.org/C115575686","wikidata":"https://www.wikidata.org/wiki/Q18822403","display_name":"Soft sensor","level":3,"score":0.3246999979019165},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.32199999690055847},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.31139999628067017},{"id":"https://openalex.org/C3020507314","wikidata":"https://www.wikidata.org/wiki/Q29034095","display_name":"Body position","level":2,"score":0.29350000619888306},{"id":"https://openalex.org/C3400440","wikidata":"https://www.wikidata.org/wiki/Q2027487","display_name":"Electro-optical sensor","level":2,"score":0.2847999930381775},{"id":"https://openalex.org/C33954974","wikidata":"https://www.wikidata.org/wiki/Q486494","display_name":"Sensor fusion","level":2,"score":0.2800000011920929},{"id":"https://openalex.org/C2908916285","wikidata":"https://www.wikidata.org/wiki/Q2118022","display_name":"Pulse Wave Analysis","level":4,"score":0.26820001006126404},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.26010000705718994},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2565999925136566},{"id":"https://openalex.org/C2776902269","wikidata":"https://www.wikidata.org/wiki/Q5165493","display_name":"Continuous monitoring","level":2,"score":0.25290000438690186}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3714394.3756170","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3714394.3756170","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Companion of the 2025 ACM International Joint Conference on Pervasive and Ubiquitous Computing","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2255363334","https://openalex.org/W2320749851","https://openalex.org/W3133847531","https://openalex.org/W4280627315","https://openalex.org/W4388507616","https://openalex.org/W4401114906"],"related_works":[],"abstract_inverted_index":{"Pulse":[0],"data":[1,23,57,103,114,124,144,149,167],"is":[2,10,27,58,196],"collected":[3,95],"using":[4,193],"a":[5,33,46,91,106,111,117,127,133,137,160,174],"photoplethysmography":[6],"(PPG)":[7],"sensor,":[8],"which":[9],"commonly":[11],"found":[12],"in":[13,79],"wearable":[14],"devices.":[15],"The":[16],"PPG":[17,108,186],"sensor":[18,26,74,109,118,128,153,171,187],"cannot":[19],"obtain":[20],"reliable":[21],"pulse":[22,56,99,148,162,166],"if":[24],"the":[25,51,63,69,73,101,113,120,123,142,147,152,155,165,170,180,185,189,194],"loosely":[28],"attached":[29],"or":[30],"positioned":[31],"on":[32,119,154],"body":[34],"part":[35],"with":[36,132,173],"fewer":[37],"blood":[38],"vessels.":[39],"To":[40],"address":[41],"this":[42],"issue,":[43],"we":[44],"propose":[45],"device":[47,61,93,156,195],"that":[48,146,179],"automatically":[49],"adjusts":[50],"sensor's":[52],"position":[53,192],"when":[54],"abnormal":[55],"detected.":[59],"This":[60,176],"eliminates":[62],"need":[64],"for":[65],"manual":[66],"intervention":[67],"by":[68],"user":[70],"and":[71,94,122],"ensures":[72],"maintains":[75],"optimal":[76,190],"placement,":[77],"even":[78],"situations":[80],"where":[81],"adjustments":[82],"are":[83],"challenging,":[84],"such":[85],"as":[86,110],"during":[87],"sleep.":[88],"We":[89],"implemented":[90],"prototype":[92],"three":[96],"types":[97],"of":[98,141,183],"data:":[100],"normal":[102,161],"obtained":[104,115,125,143,150,168],"from":[105,116,126,151,169],"fixed":[107],"baseline,":[112],"device,":[121],"worn":[129,172],"lightly":[130],"wrapped":[131],"band":[134],"to":[135,159,188],"reproduce":[136],"smart":[138],"watch.":[139],"Comparison":[140],"showed":[145],"was":[157],"closer":[158],"wave":[163],"than":[164],"band.":[175],"result":[177],"indicated":[178],"proposed":[181],"method":[182],"moving":[184],"wearing":[191],"effective.":[197]},"counts_by_year":[],"updated_date":"2025-12-30T23:08:21.542490","created_date":"2025-12-29T00:00:00"}
