{"id":"https://openalex.org/W4403376289","doi":"https://doi.org/10.1145/3678935.3678975","title":"Generating Age-Dependent Radial Artery Pulses with a Pneumatic Pulse Simulator: A Feasibility Study","display_name":"Generating Age-Dependent Radial Artery Pulses with a Pneumatic Pulse Simulator: A Feasibility Study","publication_year":2024,"publication_date":"2024-06-14","ids":{"openalex":"https://openalex.org/W4403376289","doi":"https://doi.org/10.1145/3678935.3678975"},"language":"en","primary_location":{"id":"doi:10.1145/3678935.3678975","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3678935.3678975","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 14th International Conference on Biomedical Engineering and Technology","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111399716","display_name":"Simon A. Debruin","orcid":null},"institutions":[{"id":"https://openalex.org/I83328450","display_name":"Miami University","ror":"https://ror.org/05nbqxr67","country_code":"US","type":"education","lineage":["https://openalex.org/I83328450"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Simon A. Debruin","raw_affiliation_strings":["Department of Mechanical &amp; Manufacturing Engineering, Miami University, USA"],"raw_orcid":"https://orcid.org/0009-0002-0059-0883","affiliations":[{"raw_affiliation_string":"Department of Mechanical &amp; Manufacturing Engineering, Miami University, USA","institution_ids":["https://openalex.org/I83328450"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114245579","display_name":"Ho\u00e0ng Ng\u1ecdc Thanh Nguy\u1ec5n","orcid":null},"institutions":[{"id":"https://openalex.org/I83328450","display_name":"Miami University","ror":"https://ror.org/05nbqxr67","country_code":"US","type":"education","lineage":["https://openalex.org/I83328450"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hoang N. Nguyen","raw_affiliation_strings":["Department of Chemical, Paper, and Biomedical Engineering,, Miami University, USA"],"raw_orcid":"https://orcid.org/0009-0001-1590-9335","affiliations":[{"raw_affiliation_string":"Department of Chemical, Paper, and Biomedical Engineering,, Miami University, USA","institution_ids":["https://openalex.org/I83328450"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077636043","display_name":"Jeong\u2010Hoi Koo","orcid":"https://orcid.org/0000-0001-7740-8678"},"institutions":[{"id":"https://openalex.org/I83328450","display_name":"Miami University","ror":"https://ror.org/05nbqxr67","country_code":"US","type":"education","lineage":["https://openalex.org/I83328450"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jeong-Hoi Koo","raw_affiliation_strings":["Department of Mechanical &amp; Manufacturing Engineering, Miami University, USA"],"raw_orcid":"https://orcid.org/0000-0001-7740-8678","affiliations":[{"raw_affiliation_string":"Department of Mechanical &amp; Manufacturing Engineering, Miami University, USA","institution_ids":["https://openalex.org/I83328450"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060896706","display_name":"Tae\u2010Heon Yang","orcid":"https://orcid.org/0000-0003-4316-4323"},"institutions":[{"id":"https://openalex.org/I24062138","display_name":"Konkuk University","ror":"https://ror.org/025h1m602","country_code":"KR","type":"education","lineage":["https://openalex.org/I24062138"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Tae-Heon Yang","raw_affiliation_strings":["Department of Mechanical &amp; Aerospace Engineering, Konkuk University, Republic of Korea"],"raw_orcid":"https://orcid.org/0000-0003-4316-4323","affiliations":[{"raw_affiliation_string":"Department of Mechanical &amp; Aerospace Engineering, Konkuk University, Republic of Korea","institution_ids":["https://openalex.org/I24062138"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100337287","display_name":"Young-Min Kim","orcid":"https://orcid.org/0000-0001-7417-5290"},"institutions":[{"id":"https://openalex.org/I4210087584","display_name":"Korea Institute of Oriental Medicine","ror":"https://ror.org/005rpmt10","country_code":"KR","type":"facility","lineage":["https://openalex.org/I2801339556","https://openalex.org/I4210087584","https://openalex.org/I4210144908","https://openalex.org/I4387152098"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Young-Min Kim","raw_affiliation_strings":["Digital Health Research Division, Korea Institute of Oriental Medicine, Republic of Korea"],"raw_orcid":"https://orcid.org/0000-0001-7417-5290","affiliations":[{"raw_affiliation_string":"Digital Health Research Division, Korea Institute of Oriental Medicine, Republic of Korea","institution_ids":["https://openalex.org/I4210087584"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5111399716"],"corresponding_institution_ids":["https://openalex.org/I83328450"],"apc_list":null,"apc_paid":null,"fwci":0.3826,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.67281994,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"164","last_page":"169"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.6227584481239319},{"id":"https://openalex.org/keywords/radial-artery","display_name":"Radial artery","score":0.5234922170639038},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.4976206123828888},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4780602753162384},{"id":"https://openalex.org/keywords/pulse-width-modulation","display_name":"Pulse-width modulation","score":0.4229121208190918},{"id":"https://openalex.org/keywords/artery","display_name":"Artery","score":0.25107359886169434},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20482981204986572},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17137840390205383},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.10647240281105042},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.09296709299087524},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.08622267842292786}],"concepts":[{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.6227584481239319},{"id":"https://openalex.org/C2778218979","wikidata":"https://www.wikidata.org/wiki/Q662857","display_name":"Radial artery","level":3,"score":0.5234922170639038},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4976206123828888},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4780602753162384},{"id":"https://openalex.org/C92746544","wikidata":"https://www.wikidata.org/wiki/Q585184","display_name":"Pulse-width modulation","level":3,"score":0.4229121208190918},{"id":"https://openalex.org/C2776820930","wikidata":"https://www.wikidata.org/wiki/Q9655","display_name":"Artery","level":2,"score":0.25107359886169434},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20482981204986572},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17137840390205383},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.10647240281105042},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.09296709299087524},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.08622267842292786}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3678935.3678975","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3678935.3678975","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 14th International Conference on Biomedical Engineering and Technology","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1174560748","https://openalex.org/W1980605511","https://openalex.org/W1994514865","https://openalex.org/W2024318601","https://openalex.org/W2057979612","https://openalex.org/W2065683608","https://openalex.org/W2161974745","https://openalex.org/W2199162961","https://openalex.org/W2893814198","https://openalex.org/W2923038383","https://openalex.org/W2996759704","https://openalex.org/W4205969521","https://openalex.org/W4207066759","https://openalex.org/W4213255817","https://openalex.org/W4232181702","https://openalex.org/W4312355753"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2748952813","https://openalex.org/W3083830068","https://openalex.org/W1985718209","https://openalex.org/W2023899560","https://openalex.org/W2766602978","https://openalex.org/W1977488410","https://openalex.org/W4293860303","https://openalex.org/W2373961902","https://openalex.org/W4323356533"],"abstract_inverted_index":{"Radial":[0],"pulse":[1,19,42,52,70,107,123,142,182,189],"simulators":[2],"can":[3,30],"play":[4],"an":[5,78],"important":[6],"role":[7],"in":[8,26],"the":[9,16,90,95,98,101,111,114,122,127,151,159,163,177,180],"advancement":[10],"of":[11,18,55,60,73,94,113,170,179,188],"wearable":[12],"healthcare":[13],"devices":[14],"and":[15,37,50,66,85,92,121,136,167],"modernization":[17],"diagnosis":[20],"methods,":[21],"which":[22,138],"are":[23,144],"widely":[24],"used":[25,32],"Oriental":[27],"Medicine.":[28],"They":[29],"be":[31],"to":[33,104],"calibrate":[34],"wrist-worn":[35],"sensors":[36],"train":[38],"medical":[39],"professionals":[40],"for":[41,129,150,173,184],"palpations.":[43],"This":[44],"study":[45],"proposes":[46],"a":[47,57,68,81,186],"new,":[48],"simple,":[49],"cost-effective":[51],"simulator":[53,99,183],"capable":[54],"producing":[56],"wide":[58],"range":[59,187],"blood":[61],"pressure":[62,83,103],"waveforms.":[63,108,190],"It":[64],"designed":[65],"constructed":[67],"prototype":[69,128],"simulator,":[71],"consisting":[72],"two":[74],"precision":[75],"solenoid":[76,96],"valves,":[77,97],"air":[79],"compressor,":[80],"pneumatic":[82,102],"sensor,":[84],"control":[86],"electronics.":[87],"By":[88],"controlling":[89],"opening":[91],"closing":[93],"regulates":[100],"generate":[105],"desired":[106],"To":[109],"assess":[110],"performance":[112],"prototype,":[115],"age-related":[116],"radial":[117],"pulses":[118,166,169],"were":[119],"considered,":[120],"waveforms":[124],"generated":[125],"by":[126],"representative":[130],"three":[131],"age":[132,153],"groups":[133],"(10,":[134],"50,":[135],"90-year-olds),":[137],"show":[139,157],"distinctly":[140],"different":[141],"waveforms,":[143],"compared":[145],"with":[146],"pre-existing":[147],"in-vivo":[148,168],"data":[149],"same":[152],"groups.":[154],"The":[155],"results":[156],"that":[158],"Root-Mean-Squared-Error":[160],"(RMSE)":[161],"between":[162],"experimentally":[164],"obtained":[165],"approximately":[171],"6%":[172],"all":[174],"groups,":[175],"indicating":[176],"feasibility":[178],"proposed":[181],"creating":[185]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2025-12-27T23:08:20.325037","created_date":"2025-10-10T00:00:00"}
