{"id":"https://openalex.org/W4401168534","doi":"https://doi.org/10.1145/3674225.3674251","title":"Error evaluation algorithm for capacitor voltage transformer based on improved LSTNet","display_name":"Error evaluation algorithm for capacitor voltage transformer based on improved LSTNet","publication_year":2024,"publication_date":"2024-01-19","ids":{"openalex":"https://openalex.org/W4401168534","doi":"https://doi.org/10.1145/3674225.3674251"},"language":"en","primary_location":{"id":"doi:10.1145/3674225.3674251","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1145/3674225.3674251","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 International Conference on Power Electronics and Artificial Intelligence","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085868519","display_name":"Yuexiao Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuexiao Liu","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0004-3566-8825","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074928502","display_name":"Guanghua Yang","orcid":"https://orcid.org/0009-0006-1118-8047"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Guanghua Yang","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0006-1118-8047","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Na Li","orcid":"https://orcid.org/0009-0000-0638-4939"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Na Li","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0000-0638-4939","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Rui Li","orcid":"https://orcid.org/0009-0001-6373-2036"},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Rui Li","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0001-6373-2036","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109756093","display_name":"Xiangyu Lu","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiangyu Lu","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0006-0833-1746","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040937373","display_name":"Pengbo Shi","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Pengbo Shi","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0001-5184-3345","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016375054","display_name":"Mingkai Li","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Mingkai Li","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0004-3870-5951","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5109756094","display_name":"Jinshan Zhu","orcid":null},"institutions":[{"id":"https://openalex.org/I17442442","display_name":"State Grid Corporation of China (China)","ror":"https://ror.org/05twwhs70","country_code":"CN","type":"company","lineage":["https://openalex.org/I17442442"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinshan Zhu","raw_affiliation_strings":["State Grid Beijing Electric Power Company, China"],"raw_orcid":"https://orcid.org/0009-0003-4887-8621","affiliations":[{"raw_affiliation_string":"State Grid Beijing Electric Power Company, China","institution_ids":["https://openalex.org/I17442442"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0877964,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"136","last_page":"141"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9948999881744385,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14225","display_name":"Advanced Sensor and Control Systems","score":0.9865999817848206,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13955","display_name":"Evaluation Methods in Various Fields","score":0.9861000180244446,"subfield":{"id":"https://openalex.org/subfields/2302","display_name":"Ecological Modeling"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.669204592704773},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5693516135215759},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5421593189239502},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5004239082336426},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.42141950130462646},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4019555449485779},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.3917742371559143},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21816566586494446}],"concepts":[{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.669204592704773},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5693516135215759},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5421593189239502},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5004239082336426},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.42141950130462646},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4019555449485779},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.3917742371559143},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21816566586494446}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3674225.3674251","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1145/3674225.3674251","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2024 International Conference on Power Electronics and Artificial Intelligence","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.8700000047683716,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W3139885963","https://openalex.org/W3192474593","https://openalex.org/W3206094308"],"related_works":["https://openalex.org/W2748952813","https://openalex.org/W2354365353","https://openalex.org/W2811287415","https://openalex.org/W1988437325","https://openalex.org/W2354835317","https://openalex.org/W2171140818","https://openalex.org/W2130152888","https://openalex.org/W2003918017","https://openalex.org/W2356735381","https://openalex.org/W2864363823"],"abstract_inverted_index":{"Capacitor":[0],"voltage":[1],"transformer":[2],"(CVT)":[3],"is":[4,18,25,100,124],"a":[5,56,87],"key":[6],"equipment":[7],"widely":[8],"used":[9],"in":[10,32],"high-voltage":[11],"power":[12],"systems.However,":[13],"the":[14,81,92,94,114],"structure":[15],"of":[16,96,107,116,133],"CVT":[17,42,52,57,72,108,121,134],"complex,":[19],"and":[20,40,45,66,76,85,130],"its":[21],"measurement":[22,122,135],"error":[23,43,58,74],"stability":[24],"poor,":[26],"which":[27,126],"can":[28,127],"easily":[29],"cause":[30],"losses":[31,49],"electricity":[33],"metering.":[34],"In":[35],"order":[36],"to":[37],"conduct":[38],"real-time":[39,129],"accurate":[41,104,131],"evaluation":[44,59,106,132],"avoid":[46],"energy":[47],"metering":[48],"caused":[50],"by":[51],"anomalies,":[53],"we":[54],"proposed":[55],"algorithm":[60],"based":[61],"on":[62],"an":[63],"improved":[64],"Long":[65],"short-term":[67],"time-series":[68],"network(LSTNet).":[69],"By":[70],"obtaining":[71],"historical":[73],"data":[75],"environmental":[77],"parameter":[78],"data,":[79],"training":[80],"LSTNet":[82,97],"network":[83],"model,":[84],"incorporating":[86],"temporal":[88],"multi-headed":[89],"self-attention":[90],"into":[91],"network,":[93],"accuracy":[95],"prediction":[98],"results":[99],"improved,":[101],"thus":[102],"achieving":[103],"online":[105],"errors.":[109,136],"The":[110],"experiment":[111],"shows":[112],"that":[113],"MAPE":[115],"this":[117],"method":[118],"for":[119],"predicting":[120],"errors":[123],"1.10%,":[125],"achieve":[128]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
