{"id":"https://openalex.org/W4400977138","doi":"https://doi.org/10.1145/3664476.3671013","title":"Vulnerability management digital twin for energy systems","display_name":"Vulnerability management digital twin for energy systems","publication_year":2024,"publication_date":"2024-07-25","ids":{"openalex":"https://openalex.org/W4400977138","doi":"https://doi.org/10.1145/3664476.3671013"},"language":"en","primary_location":{"id":"doi:10.1145/3664476.3671013","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3664476.3671013","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 19th International Conference on Availability, Reliability and Security","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5008504984","display_name":"Jessica B. Heluany","orcid":"https://orcid.org/0009-0000-8146-1404"},"institutions":[{"id":"https://openalex.org/I204778367","display_name":"Norwegian University of Science and Technology","ror":"https://ror.org/05xg72x27","country_code":"NO","type":"education","lineage":["https://openalex.org/I204778367"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Jessica B. Heluany","raw_affiliation_strings":["Department of Information Security and Communication Technology (IIK), Norwegian University of Science and Technology, Norway"],"raw_orcid":"https://orcid.org/0009-0000-8146-1404","affiliations":[{"raw_affiliation_string":"Department of Information Security and Communication Technology (IIK), Norwegian University of Science and Technology, Norway","institution_ids":["https://openalex.org/I204778367"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5105094291","display_name":"Johannes Goetzfried","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Johannes Goetzfried","raw_affiliation_strings":["Siemens Energy AG - Industrial Cybersecurity, Germany"],"raw_orcid":"https://orcid.org/0009-0004-0665-8783","affiliations":[{"raw_affiliation_string":"Siemens Energy AG - Industrial Cybersecurity, Germany","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5105080985","display_name":"Bernhard Mehlig","orcid":null},"institutions":[{"id":"https://openalex.org/I1325886976","display_name":"Siemens (Germany)","ror":"https://ror.org/059mq0909","country_code":"DE","type":"company","lineage":["https://openalex.org/I1325886976"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Bernhard Mehlig","raw_affiliation_strings":["Siemens Energy AG - Industrial Cybersecurity, Germany"],"raw_orcid":"https://orcid.org/0009-0002-9295-4161","affiliations":[{"raw_affiliation_string":"Siemens Energy AG - Industrial Cybersecurity, Germany","institution_ids":["https://openalex.org/I1325886976"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071334624","display_name":"Vasileios Gkioulos","orcid":"https://orcid.org/0000-0001-7304-3835"},"institutions":[{"id":"https://openalex.org/I204778367","display_name":"Norwegian University of Science and Technology","ror":"https://ror.org/05xg72x27","country_code":"NO","type":"education","lineage":["https://openalex.org/I204778367"]}],"countries":["NO"],"is_corresponding":false,"raw_author_name":"Vasileios Gkioulos","raw_affiliation_strings":["Department of Information Security and Communication Technology (IIK), Norwegian University of Science and Technology, Norway"],"raw_orcid":"https://orcid.org/0000-0001-7304-3835","affiliations":[{"raw_affiliation_string":"Department of Information Security and Communication Technology (IIK), Norwegian University of Science and Technology, Norway","institution_ids":["https://openalex.org/I204778367"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8146,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.72150176,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"11"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.982699990272522,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10734","display_name":"Information and Cyber Security","score":0.9810000061988831,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/vulnerability","display_name":"Vulnerability (computing)","score":0.7110487818717957},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6058634519577026},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.4989609718322754},{"id":"https://openalex.org/keywords/vulnerability-assessment","display_name":"Vulnerability assessment","score":0.4516144096851349},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3895503878593445},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.2805884778499603}],"concepts":[{"id":"https://openalex.org/C95713431","wikidata":"https://www.wikidata.org/wiki/Q631425","display_name":"Vulnerability (computing)","level":2,"score":0.7110487818717957},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6058634519577026},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.4989609718322754},{"id":"https://openalex.org/C167063184","wikidata":"https://www.wikidata.org/wiki/Q1400839","display_name":"Vulnerability assessment","level":3,"score":0.4516144096851349},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3895503878593445},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.2805884778499603},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C542102704","wikidata":"https://www.wikidata.org/wiki/Q183257","display_name":"Psychotherapist","level":1,"score":0.0},{"id":"https://openalex.org/C137176749","wikidata":"https://www.wikidata.org/wiki/Q4105337","display_name":"Psychological resilience","level":2,"score":0.0},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3664476.3671013","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3664476.3671013","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 19th International Conference on Availability, Reliability and Security","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8500000238418579,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2044625105","https://openalex.org/W2808052182","https://openalex.org/W3004663645","https://openalex.org/W3015380980","https://openalex.org/W3184339106","https://openalex.org/W3214913126"],"related_works":["https://openalex.org/W1883246888","https://openalex.org/W2370114625","https://openalex.org/W1756374135","https://openalex.org/W2947584067","https://openalex.org/W3118510577","https://openalex.org/W2280562859","https://openalex.org/W230721595","https://openalex.org/W3157230915","https://openalex.org/W1496728123","https://openalex.org/W2062873522"],"abstract_inverted_index":{"Increasing":[0],"cyber":[1],"attacks":[2],"underscore":[3],"the":[4,34,51,60,65,86],"importance":[5],"of":[6,18,24,36,81],"addressing":[7,121],"system":[8],"vulnerabilities":[9],"to":[10,89,96,103,112],"reduce":[11],"security":[12],"risks.":[13],"To":[14],"structure":[15],"our":[16],"workflow":[17,66],"vulnerability":[19,44],"management,":[20],"we":[21],"made":[22],"use":[23,73],"relevant":[25],"and":[26,71,92],"widely":[27],"adopted":[28],"industrial":[29],"standards,":[30],"while":[31],"also":[32,93],"incorporating":[33],"concept":[35],"digital":[37,46],"twins.":[38],"Therefore,":[39],"this":[40],"research":[41],"suggests":[42],"a":[43,77,105],"management":[45],"twin":[47],"that":[48],"aligns":[49],"with":[50,99],"ISO":[52],"23247-2":[53],"framework.":[54],"It":[55],"specifically":[56],"emphasizes":[57],"recommendations":[58],"for":[59],"\u2018data":[61],"collection\u2019":[62],"function":[63],"following":[64],"outlined":[67],"in":[68,116,120],"IEC":[69],"62443-2-3,":[70],"exemplifying":[72],"cases":[74],"based":[75],"on":[76],"typical":[78],"automation":[79],"architecture":[80],"energy":[82],"systems.":[83],"We":[84],"evaluated":[85],"CVSS":[87,98],"framework":[88],"prioritize":[90],"scores":[91],"examined":[94],"ways":[95],"integrate":[97],"other":[100],"contextual":[101],"information":[102],"develop":[104],"mitigation":[106],"deployment":[107],"strategy.":[108],"The":[109],"goal":[110],"is":[111],"assist":[113],"asset":[114],"owners":[115],"optimising":[117],"resource":[118],"utilization":[119],"vulnerabilities.":[122]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2}],"updated_date":"2025-12-23T23:11:35.936235","created_date":"2025-10-10T00:00:00"}
