{"id":"https://openalex.org/W4399324015","doi":"https://doi.org/10.1145/3643832.3661403","title":"Poster: Secure NFV Infrastructure based on Software Fault Isolation Considering Multi-Tenant Environment","display_name":"Poster: Secure NFV Infrastructure based on Software Fault Isolation Considering Multi-Tenant Environment","publication_year":2024,"publication_date":"2024-06-03","ids":{"openalex":"https://openalex.org/W4399324015","doi":"https://doi.org/10.1145/3643832.3661403"},"language":"en","primary_location":{"id":"doi:10.1145/3643832.3661403","is_oa":true,"landing_page_url":"https://doi.org/10.1145/3643832.3661403","pdf_url":"https://dl.acm.org/doi/pdf/10.1145/3643832.3661403","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 22nd Annual International Conference on Mobile Systems, Applications and Services","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://dl.acm.org/doi/pdf/10.1145/3643832.3661403","any_repository_has_fulltext":null},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101576808","display_name":"Soki Koizumi","orcid":"https://orcid.org/0009-0005-3005-1487"},"institutions":[{"id":"https://openalex.org/I203951103","display_name":"Keio University","ror":"https://ror.org/02kn6nx58","country_code":"JP","type":"education","lineage":["https://openalex.org/I203951103"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Soki Koizumi","raw_affiliation_strings":["Keio University, Yokohama, Japan"],"raw_orcid":"https://orcid.org/0009-0005-3005-1487","affiliations":[{"raw_affiliation_string":"Keio University, Yokohama, Japan","institution_ids":["https://openalex.org/I203951103"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5058950992","display_name":"Takao Kondo","orcid":"https://orcid.org/0000-0003-3572-9304"},"institutions":[{"id":"https://openalex.org/I205349734","display_name":"Hokkaido University","ror":"https://ror.org/02e16g702","country_code":"JP","type":"education","lineage":["https://openalex.org/I205349734"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Takao Kondo","raw_affiliation_strings":["Hokkaido University, Sapporo, Japan"],"raw_orcid":"https://orcid.org/0000-0003-3572-9304","affiliations":[{"raw_affiliation_string":"Hokkaido University, Sapporo, Japan","institution_ids":["https://openalex.org/I205349734"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5089613028","display_name":"Fumio Teraoka","orcid":"https://orcid.org/0000-0001-8839-3344"},"institutions":[{"id":"https://openalex.org/I203951103","display_name":"Keio University","ror":"https://ror.org/02kn6nx58","country_code":"JP","type":"education","lineage":["https://openalex.org/I203951103"]}],"countries":["JP"],"is_corresponding":false,"raw_author_name":"Fumio Teraoka","raw_affiliation_strings":["Keio University, Yokohama, Japan"],"raw_orcid":"https://orcid.org/0000-0001-8839-3344","affiliations":[{"raw_affiliation_string":"Keio University, Yokohama, Japan","institution_ids":["https://openalex.org/I203951103"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"650","last_page":"651"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11241","display_name":"Advanced Malware Detection Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/1711","display_name":"Signal Processing"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11241","display_name":"Advanced Malware Detection Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/1711","display_name":"Signal Processing"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10714","display_name":"Software-Defined Networks and 5G","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7127724885940552},{"id":"https://openalex.org/keywords/isolation","display_name":"Isolation (microbiology)","score":0.685006320476532},{"id":"https://openalex.org/keywords/network-functions-virtualization","display_name":"Network Functions Virtualization","score":0.6276918649673462},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.531852662563324},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.41601309180259705},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.24917325377464294},{"id":"https://openalex.org/keywords/cloud-computing","display_name":"Cloud computing","score":0.17370295524597168}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7127724885940552},{"id":"https://openalex.org/C2775941552","wikidata":"https://www.wikidata.org/wiki/Q25212305","display_name":"Isolation (microbiology)","level":2,"score":0.685006320476532},{"id":"https://openalex.org/C200789330","wikidata":"https://www.wikidata.org/wiki/Q7000834","display_name":"Network Functions Virtualization","level":3,"score":0.6276918649673462},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.531852662563324},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.41601309180259705},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.24917325377464294},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.17370295524597168},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C89423630","wikidata":"https://www.wikidata.org/wiki/Q7193","display_name":"Microbiology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3643832.3661403","is_oa":true,"landing_page_url":"https://doi.org/10.1145/3643832.3661403","pdf_url":"https://dl.acm.org/doi/pdf/10.1145/3643832.3661403","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 22nd Annual International Conference on Mobile Systems, Applications and Services","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1145/3643832.3661403","is_oa":true,"landing_page_url":"https://doi.org/10.1145/3643832.3661403","pdf_url":"https://dl.acm.org/doi/pdf/10.1145/3643832.3661403","source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 22nd Annual International Conference on Mobile Systems, Applications and Services","raw_type":"proceedings-article"},"sustainable_development_goals":[{"score":0.6600000262260437,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4399324015.pdf"},"referenced_works_count":5,"referenced_works":["https://openalex.org/W2079029390","https://openalex.org/W2558154288","https://openalex.org/W2985906152","https://openalex.org/W3128928115","https://openalex.org/W4308398765"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2748952813","https://openalex.org/W2167596916","https://openalex.org/W2606106394","https://openalex.org/W2496445523","https://openalex.org/W2390279801","https://openalex.org/W2358668433","https://openalex.org/W4396701345","https://openalex.org/W2376932109","https://openalex.org/W4233730885"],"abstract_inverted_index":{"Network":[0,9],"Function":[1,10],"Virtualization":[2],"Infrastructure":[3],"(NFVI)":[4],"enables":[5],"the":[6,79],"operation":[7],"of":[8,29],"Chaining":[11],"(NFC)":[12],"in":[13],"a":[14,50],"low-cost":[15],"and":[16],"flexible":[17],"manner":[18],"by":[19,64],"realizing":[20],"network":[21],"functions":[22],"as":[23],"software":[24],"on":[25,91],"general-purpose":[26],"servers.":[27],"One":[28],"NFVI's":[30],"security":[31],"requirements":[32],"is":[33,82],"access":[34,59,72],"control":[35,60],"to":[36,61],"packet":[37,62],"buffers,":[38],"which":[39],"can":[40],"be":[41],"achieved":[42],"using":[43,53],"Intra-process":[44,87],"Isolation":[45,56],"techniques.":[46],"This":[47],"paper":[48],"proposes":[49],"secure":[51],"NFVI":[52],"Software":[54],"Fault":[55],"(SFI)":[57],"for":[58],"buffers":[63],"inserting":[65],"bounds":[66],"check":[67],"instructions":[68],"before":[69],"indirect":[70],"memory":[71],"instructions.":[73],"The":[74],"measurement":[75],"results":[76],"show":[77],"that":[78],"proposed":[80],"method":[81,89],"faster":[83],"than":[84],"ERIM,":[85],"another":[86],"isolation":[88],"based":[90],"domain":[92],"switching.":[93]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
