{"id":"https://openalex.org/W4393208115","doi":"https://doi.org/10.1145/3640115.3640154","title":"Analysis of Tripping Fault of 2213 Outgoing Line Interval Circuit Breaker in a Certain Substation","display_name":"Analysis of Tripping Fault of 2213 Outgoing Line Interval Circuit Breaker in a Certain Substation","publication_year":2023,"publication_date":"2023-11-03","ids":{"openalex":"https://openalex.org/W4393208115","doi":"https://doi.org/10.1145/3640115.3640154"},"language":"en","primary_location":{"id":"doi:10.1145/3640115.3640154","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3640115.3640154","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 6th International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5013531004","display_name":"Yue Mei Han","orcid":"https://orcid.org/0009-0009-7448-4152"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yue Han","raw_affiliation_strings":["State Grid Tianjin Electric Power Company Electric Power Research Institute, China"],"raw_orcid":"https://orcid.org/0009-0009-7448-4152","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company Electric Power Research Institute, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067810593","display_name":"Guangzhen Liu","orcid":"https://orcid.org/0000-0001-9578-9574"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Guangzhen Liu","raw_affiliation_strings":["State Grid Tianjin Electric Power Company, China"],"raw_orcid":"https://orcid.org/0000-0001-9578-9574","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102726584","display_name":"Qiong Fang","orcid":"https://orcid.org/0000-0001-9418-6253"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Qiong Fang","raw_affiliation_strings":["State Grid Tianjin Electric Power Company, China"],"raw_orcid":"https://orcid.org/0000-0001-9418-6253","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014281793","display_name":"Qi Zhao","orcid":"https://orcid.org/0000-0001-9681-6597"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qi Zhao","raw_affiliation_strings":["State Grid Tianjin Electric Power Company Electric Power Research Institute, China"],"raw_orcid":"https://orcid.org/0000-0001-9681-6597","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company Electric Power Research Institute, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035881262","display_name":"Ningchuang Li","orcid":"https://orcid.org/0000-0003-2214-2395"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Nan Li","raw_affiliation_strings":["State Grid Tianjin Electric Power Company Electric Power Research Institute, China"],"raw_orcid":"https://orcid.org/0000-0003-2214-2395","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company Electric Power Research Institute, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5004382988","display_name":"Jin He","orcid":"https://orcid.org/0000-0001-6318-4474"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jin He","raw_affiliation_strings":["State Grid Tianjin Electric Power Company Electric Power Research Institute, China"],"raw_orcid":"https://orcid.org/0000-0001-6318-4474","affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company Electric Power Research Institute, China","institution_ids":["https://openalex.org/I4210097143"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"243","last_page":"250"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14042","display_name":"Technology and Security Systems","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.9302875995635986},{"id":"https://openalex.org/keywords/tripping","display_name":"Tripping","score":0.9039721488952637},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.5800349712371826},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5726184248924255},{"id":"https://openalex.org/keywords/interval","display_name":"Interval (graph theory)","score":0.5549889206886292},{"id":"https://openalex.org/keywords/residual-current-device","display_name":"Residual-current device","score":0.5251205563545227},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4918806552886963},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45646750926971436},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3385690450668335},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.30769413709640503},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.23054856061935425},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.056209444999694824}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.9302875995635986},{"id":"https://openalex.org/C2779733308","wikidata":"https://www.wikidata.org/wiki/Q17146464","display_name":"Tripping","level":3,"score":0.9039721488952637},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.5800349712371826},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5726184248924255},{"id":"https://openalex.org/C2778067643","wikidata":"https://www.wikidata.org/wiki/Q166507","display_name":"Interval (graph theory)","level":2,"score":0.5549889206886292},{"id":"https://openalex.org/C15116251","wikidata":"https://www.wikidata.org/wiki/Q337716","display_name":"Residual-current device","level":3,"score":0.5251205563545227},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4918806552886963},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45646750926971436},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3385690450668335},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30769413709640503},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.23054856061935425},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.056209444999694824},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3640115.3640154","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3640115.3640154","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 6th International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5600000023841858,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1932883711","https://openalex.org/W2085261163","https://openalex.org/W2103828746","https://openalex.org/W2104062382","https://openalex.org/W2138621811","https://openalex.org/W2582743722","https://openalex.org/W4239007999"],"related_works":["https://openalex.org/W2382192687","https://openalex.org/W3112690980","https://openalex.org/W2385711998","https://openalex.org/W2371508487","https://openalex.org/W2349376854","https://openalex.org/W2350103867","https://openalex.org/W2388594677","https://openalex.org/W2611318122","https://openalex.org/W1568616491","https://openalex.org/W2383089319"],"abstract_inverted_index":{"This":[0,101],"article":[1],"analyzes":[2],"the":[3,14,30,33,43,58,61,67,73,76,84,111,135,140,145,148,153],"circuit":[4,62,77],"breaker":[5,63,78],"opening":[6],"failure":[7],"and":[8,36,55,91,113,125,128,142,150],"overhead":[9],"ground":[10],"wire":[11],"breakage":[12],"of":[13,32,42,60,75,110,139,152],"2213":[15],"outgoing":[16,44],"line":[17,112],"at":[18],"a":[19],"certain":[20],"substation":[21],"due":[22,82],"to":[23,66,83],"multiple":[24],"lightning":[25,51,93,115,136],"strikes,":[26],"which":[27],"resulted":[28],"in":[29,97,144],"tripping":[31,79],"220kV":[34],"busbar":[35],"main":[37],"transformer.":[38],"Through":[39],"on-site":[40],"inspection":[41],"line,":[45],"protection":[46,137],"configuration":[47],"devices,":[48],"primary":[49],"equipment,":[50],"positioning":[52],"system,":[53],"etc.,":[54],"based":[56],"on":[57],"disassembly":[59],"after":[64],"returning":[65],"factory,":[68],"it":[69],"was":[70,81],"found":[71],"that":[72],"cause":[74],"fault":[80,120],"port":[85,98],"insulation":[86,99,116],"strength":[87],"not":[88],"being":[89],"restored":[90],"experiencing":[92],"overvoltage":[94],"again,":[95],"resulting":[96],"breakdown.":[100],"analysis":[102],"reflects":[103],"defects":[104],"such":[105],"as":[106],"low":[107,114],"thermal":[108],"capacity":[109],"level,":[117],"proposes":[118],"corresponding":[119],"handling":[121],"measures,":[122],"next":[123],"steps,":[124],"rectification":[126],"arrangements,":[127],"provides":[129],"reasonable":[130],"suggestions":[131],"for":[132],"comprehensively":[133],"improving":[134],"level":[138],"lines":[141],"equipment":[143],"region,":[146],"ensuring":[147],"reliability":[149],"stability":[151],"power":[154],"system.":[155]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}