{"id":"https://openalex.org/W4388738130","doi":"https://doi.org/10.1145/3606043.3606075","title":"Smart Meter Data Security Transmission Method Based on Regional Spatial Aggregation","display_name":"Smart Meter Data Security Transmission Method Based on Regional Spatial Aggregation","publication_year":2023,"publication_date":"2023-06-17","ids":{"openalex":"https://openalex.org/W4388738130","doi":"https://doi.org/10.1145/3606043.3606075"},"language":"en","primary_location":{"id":"doi:10.1145/3606043.3606075","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3606043.3606075","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2023 7th International Conference on High Performance Compilation, Computing and Communications","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5005000676","display_name":"Ziqi Dong","orcid":"https://orcid.org/0009-0003-2939-1594"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Ziqi Dong","raw_affiliation_strings":["State Grid Information &amp; Telecommunication Branch, China"],"affiliations":[{"raw_affiliation_string":"State Grid Information &amp; Telecommunication Branch, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019317543","display_name":"Yan Long","orcid":"https://orcid.org/0009-0000-6929-9053"},"institutions":[{"id":"https://openalex.org/I4210089056","display_name":"Beijing Microelectronics Technology Institute","ror":"https://ror.org/007y7ej30","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210089056"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yan Long","raw_affiliation_strings":["Beijing Smart-Chip Microelectronics Technology Co., Ltd., China"],"affiliations":[{"raw_affiliation_string":"Beijing Smart-Chip Microelectronics Technology Co., Ltd., China","institution_ids":["https://openalex.org/I4210089056"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5093276478","display_name":"Zhengyu Shang","orcid":"https://orcid.org/0009-0007-6562-1077"},"institutions":[{"id":"https://openalex.org/I163753206","display_name":"Chungbuk National University","ror":"https://ror.org/02wnxgj78","country_code":"KR","type":"education","lineage":["https://openalex.org/I163753206"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Zhengyu Shang","raw_affiliation_strings":["Chungbuk National University, South Korea"],"affiliations":[{"raw_affiliation_string":"Chungbuk National University, South Korea","institution_ids":["https://openalex.org/I163753206"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103168606","display_name":"Cong Ding","orcid":"https://orcid.org/0009-0001-5135-1615"},"institutions":[{"id":"https://openalex.org/I179060312","display_name":"Northeast Electric Power University","ror":"https://ror.org/00zqaxa34","country_code":"CN","type":"education","lineage":["https://openalex.org/I179060312"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Cong Ding","raw_affiliation_strings":["Northeast Electric Power University, China"],"affiliations":[{"raw_affiliation_string":"Northeast Electric Power University, China","institution_ids":["https://openalex.org/I179060312"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100701995","display_name":"Wei Ding","orcid":"https://orcid.org/0000-0003-4402-5616"},"institutions":[{"id":"https://openalex.org/I4210142748","display_name":"Shandong Academy of Sciences","ror":"https://ror.org/04y8d6y55","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210142748"]},{"id":"https://openalex.org/I152269853","display_name":"Qilu University of Technology","ror":"https://ror.org/04hyzq608","country_code":"CN","type":"education","lineage":["https://openalex.org/I152269853"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wei Ding","raw_affiliation_strings":["Shandong Computer Science Center (National Supercomputer Center in Jinan), Qilu University of Technology (Shandong Academy of Sciences), China"],"affiliations":[{"raw_affiliation_string":"Shandong Computer Science Center (National Supercomputer Center in Jinan), Qilu University of Technology (Shandong Academy of Sciences), China","institution_ids":["https://openalex.org/I152269853","https://openalex.org/I4210142748"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5005000676"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.1828759,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"221","last_page":"226"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13918","display_name":"Advanced Data and IoT Technologies","score":0.9836999773979187,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13429","display_name":"Electricity Theft Detection Techniques","score":0.9829000234603882,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-meter","display_name":"Smart meter","score":0.7701365947723389},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7407577037811279},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.6380314826965332},{"id":"https://openalex.org/keywords/data-aggregator","display_name":"Data aggregator","score":0.6018460988998413},{"id":"https://openalex.org/keywords/data-transmission","display_name":"Data transmission","score":0.5887625813484192},{"id":"https://openalex.org/keywords/metre","display_name":"Metre","score":0.561118483543396},{"id":"https://openalex.org/keywords/data-security","display_name":"Data security","score":0.49492019414901733},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.3874148726463318},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3579803705215454},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3222191333770752},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.1678088903427124},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.15980643033981323},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.14814865589141846},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10044446587562561}],"concepts":[{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.7701365947723389},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7407577037811279},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.6380314826965332},{"id":"https://openalex.org/C82578977","wikidata":"https://www.wikidata.org/wiki/Q16773055","display_name":"Data aggregator","level":3,"score":0.6018460988998413},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.5887625813484192},{"id":"https://openalex.org/C151011524","wikidata":"https://www.wikidata.org/wiki/Q11573","display_name":"Metre","level":2,"score":0.561118483543396},{"id":"https://openalex.org/C10511746","wikidata":"https://www.wikidata.org/wiki/Q899388","display_name":"Data security","level":3,"score":0.49492019414901733},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.3874148726463318},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3579803705215454},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3222191333770752},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.1678088903427124},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.15980643033981323},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.14814865589141846},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10044446587562561},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0},{"id":"https://openalex.org/C148730421","wikidata":"https://www.wikidata.org/wiki/Q141090","display_name":"Encryption","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3606043.3606075","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3606043.3606075","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2023 7th International Conference on High Performance Compilation, Computing and Communications","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W2963281491","https://openalex.org/W2997823310","https://openalex.org/W3010977161","https://openalex.org/W3011325267","https://openalex.org/W3022672239","https://openalex.org/W3024357298","https://openalex.org/W3033222914","https://openalex.org/W3126557344","https://openalex.org/W3159639175","https://openalex.org/W3165722858","https://openalex.org/W3172555720","https://openalex.org/W4220718716","https://openalex.org/W4220979404","https://openalex.org/W4226378691","https://openalex.org/W4289820826","https://openalex.org/W4303579410","https://openalex.org/W4313044863","https://openalex.org/W4318603370"],"related_works":["https://openalex.org/W4283216089","https://openalex.org/W2805944307","https://openalex.org/W2389925946","https://openalex.org/W1937929880","https://openalex.org/W4365794531","https://openalex.org/W2969021942","https://openalex.org/W3175936016","https://openalex.org/W3117127269","https://openalex.org/W4396918259","https://openalex.org/W3172533223"],"abstract_inverted_index":{"Aiming":[0],"at":[1],"the":[2,13,22,46,56,91,100,103,110,117,123,128],"problem":[3],"that":[4],"both":[5],"security":[6,86,93],"and":[7,64,68,90,125],"efficiency":[8],"cannot":[9],"be":[10],"achieved":[11],"in":[12,113,120],"process":[14],"of":[15,42,48,59,102,127],"transmitting":[16],"smart":[17,31,49,78],"meter":[18,32,50,79],"terminal":[19],"data":[20,33,51,60,85,92],"to":[21],"power":[23],"control":[24],"center,":[25],"this":[26,114],"paper":[27,115],"proposes":[28],"a":[29,66,77],"secure":[30],"transmission":[34,52,61,87,95],"method":[35,111,130],"based":[36,98],"on":[37,99],"regional":[38],"space":[39,81],"aggregation.":[40],"First":[41],"all,":[43],"by":[44,108],"analyzing":[45],"characteristics":[47],"business,":[53],"starting":[54],"from":[55],"three":[57],"dimensions":[58],"privacy,":[62],"accuracy,":[63],"security,":[65],"coupled":[67],"interconnected":[69],"spatial":[70],"element":[71],"index":[72],"system":[73],"is":[74,88,96],"constructed;":[75],"then,":[76],"area":[80],"aggregation":[82,94],"algorithm":[83],"for":[84],"designed,":[89],"realized":[97],"homomorphism":[101],"secret":[104],"sharing":[105],"scheme;":[106],"Finally,":[107],"comparing":[109],"proposed":[112,129],"with":[116],"dominant":[118],"algorithms":[119],"recent":[121],"years,":[122],"validity":[124],"practicability":[126],"are":[131],"verified.":[132]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
