{"id":"https://openalex.org/W4385816164","doi":"https://doi.org/10.1145/3592307.3592351","title":"Power Flow Analysis Technique for a Networked Microgrid under Grid-Connected and Islanded Operations","display_name":"Power Flow Analysis Technique for a Networked Microgrid under Grid-Connected and Islanded Operations","publication_year":2023,"publication_date":"2023-03-24","ids":{"openalex":"https://openalex.org/W4385816164","doi":"https://doi.org/10.1145/3592307.3592351"},"language":"en","primary_location":{"id":"doi:10.1145/3592307.3592351","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3592307.3592351","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2023 6th International Conference on Electronics, Communications and Control Engineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5039445372","display_name":"Wei-Chen Lin","orcid":"https://orcid.org/0000-0003-1629-7200"},"institutions":[{"id":"https://openalex.org/I70522481","display_name":"National Changhua University of Education","ror":"https://ror.org/005gkfa10","country_code":"TW","type":"education","lineage":["https://openalex.org/I70522481"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Wei-Chen Lin","raw_affiliation_strings":["Department of Industrial Education and Technology, National Changhua University of Education, Taiwan"],"raw_orcid":"https://orcid.org/0000-0003-1629-7200","affiliations":[{"raw_affiliation_string":"Department of Industrial Education and Technology, National Changhua University of Education, Taiwan","institution_ids":["https://openalex.org/I70522481"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5071403887","display_name":"Wei Huang","orcid":"https://orcid.org/0000-0003-1485-3410"},"institutions":[{"id":"https://openalex.org/I70522481","display_name":"National Changhua University of Education","ror":"https://ror.org/005gkfa10","country_code":"TW","type":"education","lineage":["https://openalex.org/I70522481"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Wei-Tzer Huang","raw_affiliation_strings":["Department of Industrial Education and Technology, National Changhua University of Education, Taiwan"],"raw_orcid":"https://orcid.org/0000-0003-1485-3410","affiliations":[{"raw_affiliation_string":"Department of Industrial Education and Technology, National Changhua University of Education, Taiwan","institution_ids":["https://openalex.org/I70522481"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044546214","display_name":"Chao-Hsien Hsiao","orcid":null},"institutions":[{"id":"https://openalex.org/I70522481","display_name":"National Changhua University of Education","ror":"https://ror.org/005gkfa10","country_code":"TW","type":"education","lineage":["https://openalex.org/I70522481"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Chao-Hsien Hsiao","raw_affiliation_strings":["Department of Industrial Education and Technology, National Changhua University of Education, Taiwan"],"raw_orcid":"https://orcid.org/0009-0004-5817-3593","affiliations":[{"raw_affiliation_string":"Department of Industrial Education and Technology, National Changhua University of Education, Taiwan","institution_ids":["https://openalex.org/I70522481"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022852228","display_name":"Kai\u2010Chao Yao","orcid":"https://orcid.org/0000-0002-5975-2392"},"institutions":[{"id":"https://openalex.org/I70522481","display_name":"National Changhua University of Education","ror":"https://ror.org/005gkfa10","country_code":"TW","type":"education","lineage":["https://openalex.org/I70522481"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Kai-Chao Yao","raw_affiliation_strings":["Department of Industrial Education and Technology, National Changhua University of Education, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-5975-2392","affiliations":[{"raw_affiliation_string":"Department of Industrial Education and Technology, National Changhua University of Education, Taiwan","institution_ids":["https://openalex.org/I70522481"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5012608771","display_name":"Liang-Ruei Chen","orcid":"https://orcid.org/0000-0002-5633-964X"},"institutions":[{"id":"https://openalex.org/I70522481","display_name":"National Changhua University of Education","ror":"https://ror.org/005gkfa10","country_code":"TW","type":"education","lineage":["https://openalex.org/I70522481"]}],"countries":["TW"],"is_corresponding":false,"raw_author_name":"Liang-Ruei Chen","raw_affiliation_strings":["Department of Electrical Engineering, National Changhua University of Education, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-5633-964X","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, National Changhua University of Education, Taiwan","institution_ids":["https://openalex.org/I70522481"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5039445372"],"corresponding_institution_ids":["https://openalex.org/I70522481"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.1072417,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"278","last_page":"282"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8286592364311218},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6740728616714478},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.5835769772529602},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.47388097643852234},{"id":"https://openalex.org/keywords/python","display_name":"Python (programming language)","score":0.47142356634140015},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.47067293524742126},{"id":"https://openalex.org/keywords/power-flow-study","display_name":"Power-flow study","score":0.47008490562438965},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.4683128297328949},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.45591673254966736},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.45021113753318787},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4375181496143341},{"id":"https://openalex.org/keywords/converters","display_name":"Converters","score":0.4297899603843689},{"id":"https://openalex.org/keywords/energy-flow","display_name":"Energy flow","score":0.4289293885231018},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.41286253929138184},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.3531719744205475},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.3352343738079071},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.3336026668548584},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.31784072518348694},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2602269649505615},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.23695632815361023},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.20713406801223755},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2053852081298828},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.19921836256980896}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8286592364311218},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6740728616714478},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5835769772529602},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.47388097643852234},{"id":"https://openalex.org/C519991488","wikidata":"https://www.wikidata.org/wiki/Q28865","display_name":"Python (programming language)","level":2,"score":0.47142356634140015},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.47067293524742126},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.47008490562438965},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.4683128297328949},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.45591673254966736},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.45021113753318787},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4375181496143341},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.4297899603843689},{"id":"https://openalex.org/C206815995","wikidata":"https://www.wikidata.org/wiki/Q1341307","display_name":"Energy flow","level":3,"score":0.4289293885231018},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.41286253929138184},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3531719744205475},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.3352343738079071},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3336026668548584},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.31784072518348694},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2602269649505615},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.23695632815361023},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.20713406801223755},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2053852081298828},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.19921836256980896},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3592307.3592351","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3592307.3592351","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2023 6th International Conference on Electronics, Communications and Control Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8299999833106995,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1977477245","https://openalex.org/W2613326656","https://openalex.org/W2901363745","https://openalex.org/W2978849801","https://openalex.org/W3138665944","https://openalex.org/W4233796619","https://openalex.org/W4312242069"],"related_works":["https://openalex.org/W2333017163","https://openalex.org/W2964937504","https://openalex.org/W2169268775","https://openalex.org/W2749199243","https://openalex.org/W4366813529","https://openalex.org/W4220876800","https://openalex.org/W2333530803","https://openalex.org/W2133545517","https://openalex.org/W2347673489","https://openalex.org/W2371966636"],"abstract_inverted_index":{"This":[0,17],"paper":[1],"proposes":[2],"a":[3,9,152],"power":[4,24,132,149,171],"flow":[5,25,133,150,172],"analytical":[6,166],"technique":[7,18,167],"for":[8,12,21,61],"networked":[10,153,174],"microgrid":[11,154],"grid-connected":[13],"and":[14,43,58,63,77,94,115],"islanded":[15],"operations.":[16],"is":[19,138],"convenient":[20],"solving":[22],"the":[23,31,34,41,53,65,75,81,87,91,95,102,107,111,127,131,135,141,148,164,170],"of":[26,37,80,151,173],"different":[27,156],"topologies":[28],"due":[29],"to":[30,51,146],"changes":[32],"in":[33,40,70,86],"switching":[35,136],"status":[36],"interconnected":[38],"switches":[39],"planning":[42],"operating":[44,157],"stages.":[45],"Furthermore,":[46],"it":[47],"can":[48,129],"be":[49],"used":[50,145],"calculate":[52],"bus":[54,76],"voltage,":[55],"line":[56],"flow,":[57],"system":[59,69,83,99],"loss":[60],"scheduling":[62],"dispatching":[64],"battery":[66,96],"energy":[67,71,97],"storage":[68,98],"management":[72],"systems.":[73],"First,":[74],"branch":[78],"data":[79,100],"sample":[82],"were":[84,104,121],"established":[85],"OpenDSS":[88,128],"software.":[89],"Next,":[90],"load,":[92],"photovoltaic,":[93],"from":[101,106],"database":[103],"obtained":[105],"metering":[108],"system.":[109],"Second,":[110],"OpenDSS,":[112],"InfluxDB":[113],"database,":[114],"Grafana":[116],"web-based":[117],"visualization":[118],"tool":[119],"programs":[120],"integrated":[122],"with":[123],"Python":[124],"language.":[125],"Then,":[126],"solve":[130,147,169],"after":[134],"state":[137],"changed.":[139],"Finally,":[140],"proposed":[142,165],"approach":[143],"was":[144],"under":[155],"conditions.":[158],"The":[159],"numerical":[160],"results":[161],"demonstrate":[162],"that":[163],"helps":[168],"microgrids.":[175]},"counts_by_year":[],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
