{"id":"https://openalex.org/W4310881614","doi":"https://doi.org/10.1145/3563357.3564061","title":"The impact of resolution of occupancy data on personal comfort model-based HVAC control performance","display_name":"The impact of resolution of occupancy data on personal comfort model-based HVAC control performance","publication_year":2022,"publication_date":"2022-11-09","ids":{"openalex":"https://openalex.org/W4310881614","doi":"https://doi.org/10.1145/3563357.3564061"},"language":"en","primary_location":{"id":"doi:10.1145/3563357.3564061","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3563357.3564061","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 9th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5022216833","display_name":"Eikichi Ono","orcid":"https://orcid.org/0000-0003-3876-1924"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Eikichi Ono","raw_affiliation_strings":["Kajima Technical Research Institute, Japan"],"affiliations":[{"raw_affiliation_string":"Kajima Technical Research Institute, Japan","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5016273194","display_name":"Yue Lei","orcid":"https://orcid.org/0000-0001-8103-7144"},"institutions":[{"id":"https://openalex.org/I165932596","display_name":"National University of Singapore","ror":"https://ror.org/01tgyzw49","country_code":"SG","type":"education","lineage":["https://openalex.org/I165932596"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Yue Lei","raw_affiliation_strings":["National University of Singapore, Singapore"],"affiliations":[{"raw_affiliation_string":"National University of Singapore, Singapore","institution_ids":["https://openalex.org/I165932596"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5047265467","display_name":"Kuniaki Mihara","orcid":"https://orcid.org/0000-0002-1402-2847"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kuniaki Mihara","raw_affiliation_strings":["Kajima Technical Research Institute Singapore, Singapore"],"affiliations":[{"raw_affiliation_string":"Kajima Technical Research Institute Singapore, Singapore","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007701465","display_name":"Adrian Chong","orcid":"https://orcid.org/0000-0002-9486-4728"},"institutions":[{"id":"https://openalex.org/I165932596","display_name":"National University of Singapore","ror":"https://ror.org/01tgyzw49","country_code":"SG","type":"education","lineage":["https://openalex.org/I165932596"]}],"countries":["SG"],"is_corresponding":false,"raw_author_name":"Adrian Chong","raw_affiliation_strings":["National University of Singapore, Singapore"],"affiliations":[{"raw_affiliation_string":"National University of Singapore, Singapore","institution_ids":["https://openalex.org/I165932596"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5022216833"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1058,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.42873825,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"254","last_page":"257"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9186999797821045,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/occupancy","display_name":"Occupancy","score":0.9154809713363647},{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8899883031845093},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.8094607591629028},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.5292391777038574},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4932352900505066},{"id":"https://openalex.org/keywords/data-modeling","display_name":"Data modeling","score":0.42491644620895386},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.4126531183719635},{"id":"https://openalex.org/keywords/architectural-engineering","display_name":"Architectural engineering","score":0.3535618185997009},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.34236690402030945},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2964531183242798},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.1634838581085205},{"id":"https://openalex.org/keywords/geography","display_name":"Geography","score":0.12021461129188538},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.10242360830307007},{"id":"https://openalex.org/keywords/meteorology","display_name":"Meteorology","score":0.06999599933624268}],"concepts":[{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.9154809713363647},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8899883031845093},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.8094607591629028},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.5292391777038574},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4932352900505066},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.42491644620895386},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4126531183719635},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.3535618185997009},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.34236690402030945},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2964531183242798},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.1634838581085205},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.12021461129188538},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.10242360830307007},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.06999599933624268},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3563357.3564061","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3563357.3564061","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 9th ACM International Conference on Systems for Energy-Efficient Buildings, Cities, and Transportation","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":12,"referenced_works":["https://openalex.org/W2079922090","https://openalex.org/W2762557954","https://openalex.org/W2783850388","https://openalex.org/W2976484007","https://openalex.org/W3028491587","https://openalex.org/W3048913341","https://openalex.org/W3121926635","https://openalex.org/W3123621884","https://openalex.org/W3135155481","https://openalex.org/W3210222877","https://openalex.org/W4281749375","https://openalex.org/W4285822757"],"related_works":["https://openalex.org/W3045934583","https://openalex.org/W2437015738","https://openalex.org/W4312641736","https://openalex.org/W4283833227","https://openalex.org/W3093054803","https://openalex.org/W2357294886","https://openalex.org/W3038059713","https://openalex.org/W4281749375","https://openalex.org/W2079922090","https://openalex.org/W2017084161"],"abstract_inverted_index":{"Data-driven":[0],"thermal":[1,17,77,141],"comfort":[2,21,34,78,82,142],"models":[3,22,143],"play":[4],"an":[5,134],"important":[6],"role":[7],"in":[8,16,125],"occupant-centric":[9,145],"HVAC":[10,146],"controls":[11,36,85,118],"to":[12,25,74,112,122],"satisfy":[13],"occupants'":[14,27],"preferences":[15,28],"comfort.":[18],"Although":[19],"personal":[20,33,81],"are":[23],"likely":[24],"predict":[26],"well,":[29],"the":[30,41,76,104,130],"performance":[31,79],"of":[32,43,53,80,89,106,132,137],"model-based":[35,83],"might":[37],"be":[38],"affected":[39],"by":[40,70,109],"resolution":[42,52,136],"occupancy":[44,90,101,114,138],"data":[45,91,102,139],"when":[46],"incorporating":[47],"them":[48],"into":[49],"a":[50,62,66,71],"lower":[51],"control":[54,73,124],"(i.e.,":[55],"group-":[56],"or":[57],"zone-level":[58],"control).":[59],"We":[60],"conducted":[61],"field":[63],"experiment":[64],"at":[65],"university":[67],"office":[68],"air-conditioned":[69],"group-level":[72,113,117],"evaluate":[75],"optimal":[84],"with":[86],"different":[87],"resolutions":[88],"(personal-":[92],"and":[93,140],"group-level).":[94],"The":[95],"results":[96],"showed":[97],"that":[98],"using":[99],"personal-level":[100,123],"increased":[103],"percentage":[105],"\"comfortable\"":[107],"votes":[108],"8%":[110],"compared":[111],"data.":[115],"Even":[116],"can":[119],"behave":[120],"similarly":[121],"partially-occupied":[126],"situations.":[127],"This":[128],"highlights":[129],"importance":[131],"selecting":[133],"appropriate":[135],"for":[144],"controls.":[147]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
