{"id":"https://openalex.org/W4307335340","doi":"https://doi.org/10.1145/3558819.3565173","title":"Design and implementation of carbon dioxide sensor based on energy acquisition technology","display_name":"Design and implementation of carbon dioxide sensor based on energy acquisition technology","publication_year":2022,"publication_date":"2022-09-23","ids":{"openalex":"https://openalex.org/W4307335340","doi":"https://doi.org/10.1145/3558819.3565173"},"language":"en","primary_location":{"id":"doi:10.1145/3558819.3565173","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3558819.3565173","pdf_url":null,"source":{"id":"https://openalex.org/S4363608855","display_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108096078","display_name":"Ren Chen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ren Chen","raw_affiliation_strings":["Liaoning Institute of Science and Technology, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Liaoning Institute of Science and Technology, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042965582","display_name":"Hong Cheng","orcid":"https://orcid.org/0000-0001-5532-9530"},"institutions":[{"id":"https://openalex.org/I4210106378","display_name":"Dalian Municipal Central Hospital","ror":"https://ror.org/01n6v0a11","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210106378"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hong Cheng","raw_affiliation_strings":["Dalian Municipal Public Utility Service Center, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dalian Municipal Public Utility Service Center, China","institution_ids":["https://openalex.org/I4210106378"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"701","last_page":"704"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10461","display_name":"Gas Sensing Nanomaterials and Sensors","score":0.9402999877929688,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10461","display_name":"Gas Sensing Nanomaterials and Sensors","score":0.9402999877929688,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12120","display_name":"Air Quality Monitoring and Forecasting","score":0.9196000099182129,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5980836749076843},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5654897093772888},{"id":"https://openalex.org/keywords/data-acquisition","display_name":"Data acquisition","score":0.5598783493041992},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5372272729873657},{"id":"https://openalex.org/keywords/wireless-sensor-network","display_name":"Wireless sensor network","score":0.5339853167533875},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.506138026714325},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.4756685793399811},{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.45487651228904724},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.4395603537559509},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39331766963005066},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.33718499541282654},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3293742537498474}],"concepts":[{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5980836749076843},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5654897093772888},{"id":"https://openalex.org/C163985040","wikidata":"https://www.wikidata.org/wiki/Q1172399","display_name":"Data acquisition","level":2,"score":0.5598783493041992},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5372272729873657},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.5339853167533875},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.506138026714325},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.4756685793399811},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.45487651228904724},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4395603537559509},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39331766963005066},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.33718499541282654},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3293742537498474},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3558819.3565173","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3558819.3565173","pdf_url":null,"source":{"id":"https://openalex.org/S4363608855","display_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8399999737739563,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":1,"referenced_works":["https://openalex.org/W4292932666"],"related_works":["https://openalex.org/W2386968573","https://openalex.org/W2395064349","https://openalex.org/W2034374297","https://openalex.org/W2382628689","https://openalex.org/W2766130412","https://openalex.org/W2526730640","https://openalex.org/W2351171996","https://openalex.org/W2983370139","https://openalex.org/W2084724079","https://openalex.org/W2111773953"],"abstract_inverted_index":{"A":[0],"self":[1],"powered":[2],"CO2":[3,42,57],"sensor":[4,43,58,73],"with":[5,26],"energy":[6,23],"optimization":[7],"and":[8,19,40,52,91,97],"intelligent":[9],"measurement":[10],"concept":[11],"based":[12],"on":[13,22],"stm300":[14,34],"radio":[15],"module":[16,35],"is":[17,95,107],"designed":[18],"implemented.":[20],"Based":[21],"acquisition":[24,46,55],"technology,":[25],"solar":[27],"panel":[28],"as":[29,36,44],"the":[30,37,45,48,66],"power":[31,50,74,78,84],"supply":[32,51,85],"core,":[33],"control":[38],"core":[39],"gss-cozir":[41],"module,":[47],"effective":[49],"accurate":[53],"concentration":[54],"of":[56,68,72,82],"in":[59],"photovoltaic":[60],"mode":[61,94],"are":[62],"realized.":[63],"Aiming":[64],"at":[65],"problem":[67],"short":[69],"service":[70],"life":[71],"supply,":[75],"a":[76],"dynamic":[77],"consumption":[79],"analysis":[80],"method":[81,101],"balancing":[83],"by":[86],"using":[87],"its":[88],"working":[89],"cycle":[90],"low-power":[92],"off":[93],"proposed,":[96],"an":[98],"automatic":[99],"calibration":[100],"for":[102],"error":[103],"under":[104],"long-term":[105],"trial":[106],"given.":[108]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
