{"id":"https://openalex.org/W4307335273","doi":"https://doi.org/10.1145/3558819.3565080","title":"DC Bias Diagnosis of Power Transformer with Soundprint Features","display_name":"DC Bias Diagnosis of Power Transformer with Soundprint Features","publication_year":2022,"publication_date":"2022-09-23","ids":{"openalex":"https://openalex.org/W4307335273","doi":"https://doi.org/10.1145/3558819.3565080"},"language":"en","primary_location":{"id":"doi:10.1145/3558819.3565080","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3558819.3565080","pdf_url":null,"source":{"id":"https://openalex.org/S4363608855","display_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5043578689","display_name":"Shaohua Han","orcid":null},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Shaohua Han","raw_affiliation_strings":["Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024185754","display_name":"Xinqiang Wan","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xinqiang Wan","raw_affiliation_strings":["Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030139583","display_name":"Yong Lai","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yong Lai","raw_affiliation_strings":["Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101809046","display_name":"Lei Ge","orcid":"https://orcid.org/0000-0002-9377-2530"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Lei Ge","raw_affiliation_strings":["Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5028172656","display_name":"Jinian Pang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jinian Pang","raw_affiliation_strings":["Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Suqian Power Supply Branch of State Grid Jiangsu Electric Power Co., Ltd, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5043578689"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.8671,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.92296185,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"213","last_page":"217"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dc-bias","display_name":"DC bias","score":0.735467255115509},{"id":"https://openalex.org/keywords/autotransformer","display_name":"Autotransformer","score":0.6150532960891724},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5549530982971191},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.5015461444854736},{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.4608791172504425},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4496576488018036},{"id":"https://openalex.org/keywords/energy-efficient-transformer","display_name":"Energy efficient transformer","score":0.4437098801136017},{"id":"https://openalex.org/keywords/isolation-transformer","display_name":"Isolation transformer","score":0.41576820611953735},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.40570762753486633},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3901631236076355},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3319738507270813},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17567238211631775}],"concepts":[{"id":"https://openalex.org/C88682704","wikidata":"https://www.wikidata.org/wiki/Q2907415","display_name":"DC bias","level":3,"score":0.735467255115509},{"id":"https://openalex.org/C22958824","wikidata":"https://www.wikidata.org/wiki/Q565668","display_name":"Autotransformer","level":5,"score":0.6150532960891724},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5549530982971191},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.5015461444854736},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.4608791172504425},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4496576488018036},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.4437098801136017},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.41576820611953735},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40570762753486633},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3901631236076355},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3319738507270813},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17567238211631775}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3558819.3565080","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3558819.3565080","pdf_url":null,"source":{"id":"https://openalex.org/S4363608855","display_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 7th International Conference on Cyber Security and Information Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8500000238418579}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W828339006","https://openalex.org/W1983463800","https://openalex.org/W2364993376","https://openalex.org/W2380910501","https://openalex.org/W2393076835","https://openalex.org/W2871515941","https://openalex.org/W2938731450","https://openalex.org/W2948073450","https://openalex.org/W3139714490","https://openalex.org/W4232156911"],"related_works":["https://openalex.org/W2038727167","https://openalex.org/W4211148719","https://openalex.org/W2388178350","https://openalex.org/W2991413088","https://openalex.org/W2005785045","https://openalex.org/W1532785464","https://openalex.org/W2139405734","https://openalex.org/W2149641118","https://openalex.org/W2366381755","https://openalex.org/W2390989651"],"abstract_inverted_index":{"DC":[0,15,37,49,104,131,150],"bias":[1,16,38,50,105,132,151],"is":[2,39,74,124],"a":[3,121],"common":[4],"safety":[5],"threat":[6],"of":[7,18,36,51,58,68,80,107,120,134,153],"AC":[8],"power":[9,19,53,72,135,154],"transformers.":[10],"In":[11],"order":[12],"to":[13],"diagnose":[14],"problem":[17],"transformer,":[20],"an":[21],"acoustic":[22],"method":[23,142],"based":[24],"on":[25,95],"soundprint":[26,62,82,97],"features":[27,63,83,98],"are":[28,44,64,84,92],"proposed":[29,115],"in":[30],"this":[31],"paper.":[32],"The":[33,41,66,77,126,141],"generation":[34],"mechanism":[35],"introduced.":[40],"noise":[42,67],"signals":[43],"tested":[45],"before":[46],"and":[47,87,99],"after":[48],"the":[52,59,88,96,100,103,108,114,117,149],"transformer.":[54,155],"After":[55],"spectral":[56],"comparison":[57],"signals,":[60],"four":[61],"extracted.":[65],"more":[69],"than":[70],"150":[71],"transformers":[73],"measured":[75],"onsite.":[76],"distribution":[78],"characteristics":[79],"these":[81],"statistically":[85],"analyzed":[86],"corresponding":[89],"threshold":[90,101],"values":[91],"determined.":[93],"Based":[94],"values,":[102],"state":[106,119,133],"transformer":[109,136],"can":[110,137,143],"be":[111,138,144],"recognized.":[112],"With":[113],"methodology,":[116],"operation":[118],"500kV":[122],"autotransformer":[123],"diagnosed.":[125],"application":[127],"result":[128],"shows":[129],"that":[130],"accurately":[139],"detected.":[140],"used":[145],"as":[146],"reference":[147],"for":[148],"detection":[152]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
