{"id":"https://openalex.org/W4320067904","doi":"https://doi.org/10.1145/3547276.3548632","title":"Frequency Recovery in Power Grids using High-Performance Computing","display_name":"Frequency Recovery in Power Grids using High-Performance Computing","publication_year":2022,"publication_date":"2022-08-29","ids":{"openalex":"https://openalex.org/W4320067904","doi":"https://doi.org/10.1145/3547276.3548632"},"language":"en","primary_location":{"id":"doi:10.1145/3547276.3548632","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3547276.3548632","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Workshop Proceedings of the 51st International Conference on Parallel Processing","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082476958","display_name":"Vishwas Rao","orcid":"https://orcid.org/0000-0002-4395-6075"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Vishwas Rao","raw_affiliation_strings":["Argonne National Laboratory, United States of America"],"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, United States of America","institution_ids":["https://openalex.org/I1282105669"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5055694082","display_name":"Anirudh Subramanyam","orcid":"https://orcid.org/0000-0001-5255-8821"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Anirudh Subramanyam","raw_affiliation_strings":["Argonne National Laboratory, United States of America"],"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, United States of America","institution_ids":["https://openalex.org/I1282105669"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5011552443","display_name":"Michel Schanen","orcid":"https://orcid.org/0000-0002-4164-027X"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Michel Schanen","raw_affiliation_strings":["Argonne National Laboratory, United States of America"],"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, United States of America","institution_ids":["https://openalex.org/I1282105669"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101681633","display_name":"Youngdae Kim","orcid":"https://orcid.org/0000-0001-9392-6192"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Youngdae Kim","raw_affiliation_strings":["Argonne National Laboratory, USA"],"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, USA","institution_ids":["https://openalex.org/I1282105669"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009711210","display_name":"Ignas Satkauskas","orcid":null},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Renewable Energy Laboratory","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ignas Satkauskas","raw_affiliation_strings":["National Renewable Energy Laboratory, United States of America"],"affiliations":[{"raw_affiliation_string":"National Renewable Energy Laboratory, United States of America","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5000943506","display_name":"Mihai Anitescu","orcid":"https://orcid.org/0000-0002-0787-5462"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Mihai Anitescu","raw_affiliation_strings":["Argonne National Laboratory, United States of America"],"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, United States of America","institution_ids":["https://openalex.org/I1282105669"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5082476958"],"corresponding_institution_ids":["https://openalex.org/I1282105669"],"apc_list":null,"apc_paid":null,"fwci":0.0969,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.43743345,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9991999864578247,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.6463254690170288},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6149083375930786},{"id":"https://openalex.org/keywords/automatic-frequency-control","display_name":"Automatic frequency control","score":0.6103366613388062},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.5707512497901917},{"id":"https://openalex.org/keywords/nonlinear-system","display_name":"Nonlinear system","score":0.5313497185707092},{"id":"https://openalex.org/keywords/model-predictive-control","display_name":"Model predictive control","score":0.5129780173301697},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.5047365427017212},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5001587867736816},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.4988737106323242},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.482614129781723},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.4484696686267853},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.4286614954471588},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4076237678527832},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3527931869029999},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.259307861328125},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2551022171974182},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.22335124015808105},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.13191679120063782},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.1282690167427063},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.10161137580871582}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6463254690170288},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6149083375930786},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6103366613388062},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.5707512497901917},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.5313497185707092},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.5129780173301697},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.5047365427017212},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5001587867736816},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4988737106323242},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.482614129781723},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4484696686267853},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.4286614954471588},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4076237678527832},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3527931869029999},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.259307861328125},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2551022171974182},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.22335124015808105},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.13191679120063782},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.1282690167427063},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.10161137580871582},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3547276.3548632","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3547276.3548632","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Workshop Proceedings of the 51st International Conference on Parallel Processing","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.5899999737739563,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W2036039628","https://openalex.org/W2109189685","https://openalex.org/W2142534131","https://openalex.org/W2146513799","https://openalex.org/W2395721918","https://openalex.org/W2511473841","https://openalex.org/W2543274172","https://openalex.org/W2782740643","https://openalex.org/W2902041647","https://openalex.org/W2911464544","https://openalex.org/W3004291705","https://openalex.org/W3116067580","https://openalex.org/W3132153045","https://openalex.org/W6968739661"],"related_works":["https://openalex.org/W1990079087","https://openalex.org/W2060165215","https://openalex.org/W2101188133","https://openalex.org/W3202234113","https://openalex.org/W4248731570","https://openalex.org/W2320869598","https://openalex.org/W2381210024","https://openalex.org/W2384015130","https://openalex.org/W2094121346","https://openalex.org/W4285595274"],"abstract_inverted_index":{"Maintaining":[0],"electric":[1,118],"power":[2,66,109,119],"system":[3,38,55,67],"stability":[4],"is":[5,50,61,89,100],"paramount,":[6],"especially":[7],"in":[8,169],"extreme":[9],"contingencies":[10],"involving":[11],"unexpected":[12],"outages":[13,28],"of":[14,47,54,65,95,129,171,187],"multiple":[15,96],"generators":[16],"or":[17],"transmission":[18],"lines":[19],"that":[20,113,147],"are":[21,181],"typical":[22],"during":[23],"severe":[24],"weather":[25],"events.":[26],"Such":[27],"often":[29],"lead":[30],"to":[31,82],"large":[32],"supply-demand":[33],"mismatches":[34],"followed":[35],"by":[36,91],"subsequent":[37],"frequency":[39,48,84,127,172],"deviations":[40,49,85],"from":[41,149],"their":[42],"nominal":[43],"value.":[44],"The":[45],"extent":[46],"an":[51,92],"important":[52],"metric":[53],"resilience,":[56],"and":[57,69,122,125,153],"its":[58],"timely":[59],"mitigation":[60],"a":[62,74,103,135],"central":[63],"goal":[64],"operation":[68],"control.":[70],"This":[71],"paper":[72],"develops":[73],"novel":[75,104],"nonlinear":[76,117,144],"model":[77],"predictive":[78],"control":[79,131],"(NMPC)":[80],"method":[81,99,152,165],"minimize":[83],"when":[86],"the":[87,123,142,185],"grid":[88],"affected":[90],"unforeseen":[93],"loss":[94],"components.":[97],"Our":[98,164],"based":[101,183],"on":[102,159,184],"multi-period":[105],"alternating":[106],"current":[107],"optimal":[108],"flow":[110,120],"(ACOPF)":[111],"formulation":[112],"accurately":[114],"models":[115],"both":[116],"physics":[121],"primary":[124],"secondary":[126],"response":[128],"generator":[130,179],"mechanisms.":[132],"We":[133],"develop":[134],"distributed":[136],"parallel":[137],"Julia":[138],"package":[139],"for":[140],"solving":[141],"large-scale":[143],"optimization":[145],"problems":[146],"result":[148],"our":[150],"NMPC":[151],"thereby":[154],"address":[155],"realistic":[156],"test":[157],"instances":[158],"existing":[160,175],"high-performance":[161],"computing":[162],"architectures.":[163],"demonstrates":[166],"superior":[167],"performance":[168],"terms":[170],"recovery":[173],"over":[174],"industry":[176],"practices,":[177],"where":[178],"levels":[180],"set":[182],"solution":[186],"single-period":[188],"classical":[189],"ACOPF":[190],"models.":[191]},"counts_by_year":[{"year":2024,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
