{"id":"https://openalex.org/W4226343455","doi":"https://doi.org/10.1145/3508297.3508322","title":"Simulation and Analysis on Influence Factors and Restraining Effect of Arc Over-voltage Amplitude in 10kV Network System","display_name":"Simulation and Analysis on Influence Factors and Restraining Effect of Arc Over-voltage Amplitude in 10kV Network System","publication_year":2021,"publication_date":"2021-12-03","ids":{"openalex":"https://openalex.org/W4226343455","doi":"https://doi.org/10.1145/3508297.3508322"},"language":"en","primary_location":{"id":"doi:10.1145/3508297.3508322","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3508297.3508322","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 4th International Conference on Electronics and Electrical Engineering Technology","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100760302","display_name":"Bo Liu","orcid":"https://orcid.org/0000-0001-5110-4887"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu Bo","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100944836","display_name":"Han Jian","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Han Jian","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100411539","display_name":"Xiao Wang","orcid":"https://orcid.org/0009-0002-7608-7619"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang Xiao","raw_affiliation_strings":["Huangshi Power Supply Company of State Grid Hubei Electric Power Co .,Ltd, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huangshi Power Supply Company of State Grid Hubei Electric Power Co .,Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100334255","display_name":"Bin Liu","orcid":"https://orcid.org/0000-0002-8278-1589"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu Bin","raw_affiliation_strings":["Huangshi Power Supply Company of State Grid Hubei Electric Power Co .,Ltd, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Huangshi Power Supply Company of State Grid Hubei Electric Power Co .,Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5054037924","display_name":"Shouwen Liu","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu Shouwen","raw_affiliation_strings":["Hubei Electric Power Limited Company, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hubei Electric Power Limited Company, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083374652","display_name":"Wei Zhen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wei Zhen","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Guo Lisha","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Guo Lisha","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100446554","display_name":"Zhuo Wang","orcid":"https://orcid.org/0000-0001-5591-9549"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang Zhuo","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5061027581","display_name":"Wenlan Li","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li Wenlan","raw_affiliation_strings":["NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"NARI GROUP Liability Corporation, State Grid Electric Power Research Institue Liability Corporation, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"151","last_page":"158"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.983299970626831,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.983299970626831,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9656999707221985,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12371","display_name":"Electrical Contact Performance and Analysis","score":0.939300000667572,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground","display_name":"Ground","score":0.7764227390289307},{"id":"https://openalex.org/keywords/arc-suppression","display_name":"Arc suppression","score":0.7526739239692688},{"id":"https://openalex.org/keywords/emtp","display_name":"Emtp","score":0.6838643550872803},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5808902978897095},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.573764443397522},{"id":"https://openalex.org/keywords/arc","display_name":"Arc (geometry)","score":0.5513269901275635},{"id":"https://openalex.org/keywords/earthing-system","display_name":"Earthing system","score":0.5486122965812683},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.543282151222229},{"id":"https://openalex.org/keywords/overvoltage","display_name":"Overvoltage","score":0.5384767651557922},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5371158123016357},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.49933481216430664},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4948732256889343},{"id":"https://openalex.org/keywords/lightning-arrester","display_name":"Lightning arrester","score":0.4828491806983948},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.39579424262046814},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.15761399269104004},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.13257816433906555},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.07042431831359863}],"concepts":[{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.7764227390289307},{"id":"https://openalex.org/C2779234724","wikidata":"https://www.wikidata.org/wiki/Q4785039","display_name":"Arc suppression","level":4,"score":0.7526739239692688},{"id":"https://openalex.org/C2778363592","wikidata":"https://www.wikidata.org/wiki/Q5374837","display_name":"Emtp","level":4,"score":0.6838643550872803},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5808902978897095},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.573764443397522},{"id":"https://openalex.org/C83415579","wikidata":"https://www.wikidata.org/wiki/Q161973","display_name":"Arc (geometry)","level":2,"score":0.5513269901275635},{"id":"https://openalex.org/C78779171","wikidata":"https://www.wikidata.org/wiki/Q432571","display_name":"Earthing system","level":3,"score":0.5486122965812683},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.543282151222229},{"id":"https://openalex.org/C15703209","wikidata":"https://www.wikidata.org/wiki/Q333883","display_name":"Overvoltage","level":3,"score":0.5384767651557922},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5371158123016357},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.49933481216430664},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4948732256889343},{"id":"https://openalex.org/C105161833","wikidata":"https://www.wikidata.org/wiki/Q5530572","display_name":"Lightning arrester","level":2,"score":0.4828491806983948},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39579424262046814},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.15761399269104004},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.13257816433906555},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.07042431831359863},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3508297.3508322","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3508297.3508322","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 4th International Conference on Electronics and Electrical Engineering Technology","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Good health and well-being","score":0.5799999833106995,"id":"https://metadata.un.org/sdg/3"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2351631284","https://openalex.org/W4231349378","https://openalex.org/W2144718382","https://openalex.org/W4391307765","https://openalex.org/W4367032236","https://openalex.org/W4367032346","https://openalex.org/W4379525221","https://openalex.org/W2372247511","https://openalex.org/W2064169725","https://openalex.org/W2735439336"],"abstract_inverted_index":{"The":[0,38],"Over-voltage":[1],"such":[2],"as":[3,159],"operation,":[4],"current":[5],"closure,":[6],"resonance":[7],"and":[8,21,45,72,132,140,147],"lightning":[9],"strike":[10],"in":[11,51,81],"power":[12,47,82],"system":[13,48],"all":[14],"threaten":[15],"the":[16,22,27,35,46,57,60,64,85,97,105,113,118,126,134,153,165],"insulation":[17],"of":[18,59,87,101,121,129,136],"electrical":[19],"equipment":[20],"safe":[23],"operation":[24],"state,":[25],"especially":[26],"single":[28],"phase":[29],"intermittent":[30],"arc":[31,69,78,98,130,137,145,167],"grounding":[32,40,79,99,168],"over-voltage":[33,80,122,131,146,169],"is":[34,89,109],"most":[36],"serious.":[37],"single-phase":[39],"often":[41],"becomes":[42],"multi-phase":[43],"grounding,":[44],"was":[49],"blackout":[50],"a":[52],"large":[53],"area":[54],"due":[55],"to":[56,76,111,155,160],"expansion":[58],"accident":[61],"caused":[62],"by":[63],"untimely":[65],"treatment.":[66],"At":[67],"present,":[68],"suppression":[70,138],"coil":[71,139],"arrester":[73,143],"are":[74],"used":[75,110],"suppress":[77],"grid,":[83],"but":[84],"effect":[86,135],"application":[88],"not":[90],"ideal.":[91],"In":[92],"this":[93],"paper,":[94],"aiming":[95],"at":[96],"fault":[100],"distribution":[102],"network":[103],"system,":[104],"EMTP":[106],"simulation":[107,114,119],"software":[108],"establish":[112],"model,":[115],"carry":[116],"out":[117],"analysis":[120],"characteristics,":[123],"then":[124],"study":[125],"influence":[127],"factors":[128],"compare":[133],"zinc":[141],"oxide":[142],"on":[144],"their":[148],"respective":[149],"shortcomings.":[150],"Then":[151],"propose":[152],"parameters":[154],"be":[156],"improved,":[157],"so":[158],"provide":[161],"parameter":[162],"guidance":[163],"for":[164],"new":[166],"device.":[170]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
