{"id":"https://openalex.org/W4234218527","doi":"https://doi.org/10.1145/3495018.3495024","title":"Experimental Research on Enhanced Heat Transfer of Pulsating Flow Based on Plate Heat Exchanger","display_name":"Experimental Research on Enhanced Heat Transfer of Pulsating Flow Based on Plate Heat Exchanger","publication_year":2021,"publication_date":"2021-10-23","ids":{"openalex":"https://openalex.org/W4234218527","doi":"https://doi.org/10.1145/3495018.3495024"},"language":"en","primary_location":{"id":"doi:10.1145/3495018.3495024","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3495018.3495024","pdf_url":null,"source":{"id":"https://openalex.org/S4363607741","display_name":"2021 3rd International Conference on Artificial Intelligence and Advanced Manufacture","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 3rd International Conference on Artificial Intelligence and Advanced Manufacture","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100384901","display_name":"Jun Wang","orcid":"https://orcid.org/0000-0003-2569-1461"},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Jun Wang","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101876837","display_name":"Yu Hou","orcid":"https://orcid.org/0000-0003-4462-7924"},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yu Hou","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112892730","display_name":"Xiaolong Lin","orcid":null},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaolong Lin","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030687588","display_name":"Ruoxi Ding","orcid":"https://orcid.org/0000-0002-4515-034X"},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ruoxi Ding","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100732105","display_name":"Yaohui Liu","orcid":"https://orcid.org/0000-0002-3041-3557"},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yaohui Liu","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021470022","display_name":"Kolgatov Anton","orcid":null},"institutions":[{"id":"https://openalex.org/I4210096899","display_name":"Jiangsu University of Science and Technology","ror":"https://ror.org/00tyjp878","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210096899"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kolgatov Anton","raw_affiliation_strings":["Jiangsu University of Science and Technology, China"],"affiliations":[{"raw_affiliation_string":"Jiangsu University of Science and Technology, China","institution_ids":["https://openalex.org/I4210096899"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5100384901"],"corresponding_institution_ids":["https://openalex.org/I4210096899"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.41601969,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"33","last_page":"38"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11945","display_name":"Heat Transfer Mechanisms","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/plate-heat-exchanger","display_name":"Plate heat exchanger","score":0.7873486280441284},{"id":"https://openalex.org/keywords/plate-fin-heat-exchanger","display_name":"Plate fin heat exchanger","score":0.7301902770996094},{"id":"https://openalex.org/keywords/heat-spreader","display_name":"Heat spreader","score":0.7036074995994568},{"id":"https://openalex.org/keywords/moving-bed-heat-exchanger","display_name":"Moving bed heat exchanger","score":0.6687991619110107},{"id":"https://openalex.org/keywords/heat-transfer","display_name":"Heat transfer","score":0.64836585521698},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.6280599236488342},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.6011550426483154},{"id":"https://openalex.org/keywords/micro-heat-exchanger","display_name":"Micro heat exchanger","score":0.5879262685775757},{"id":"https://openalex.org/keywords/dynamic-scraped-surface-heat-exchanger","display_name":"Dynamic scraped surface heat exchanger","score":0.5335578918457031},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.49855947494506836},{"id":"https://openalex.org/keywords/heat-transfer-enhancement","display_name":"Heat transfer enhancement","score":0.4962626099586487},{"id":"https://openalex.org/keywords/ntu-method","display_name":"NTU method","score":0.49612483382225037},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.41952207684516907},{"id":"https://openalex.org/keywords/regenerative-heat-exchanger","display_name":"Regenerative heat exchanger","score":0.41293978691101074},{"id":"https://openalex.org/keywords/heat-transfer-coefficient","display_name":"Heat transfer coefficient","score":0.39503344893455505},{"id":"https://openalex.org/keywords/nuclear-engineering","display_name":"Nuclear engineering","score":0.37828952074050903},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.33372265100479126},{"id":"https://openalex.org/keywords/thermodynamics","display_name":"Thermodynamics","score":0.3275565505027771},{"id":"https://openalex.org/keywords/critical-heat-flux","display_name":"Critical heat flux","score":0.32624882459640503},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.16592621803283691},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.15635645389556885}],"concepts":[{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.7873486280441284},{"id":"https://openalex.org/C39420092","wikidata":"https://www.wikidata.org/wiki/Q17075298","display_name":"Plate fin heat exchanger","level":4,"score":0.7301902770996094},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.7036074995994568},{"id":"https://openalex.org/C23523640","wikidata":"https://www.wikidata.org/wiki/Q6927133","display_name":"Moving bed heat exchanger","level":5,"score":0.6687991619110107},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.64836585521698},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.6280599236488342},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.6011550426483154},{"id":"https://openalex.org/C118227150","wikidata":"https://www.wikidata.org/wiki/Q6839192","display_name":"Micro heat exchanger","level":4,"score":0.5879262685775757},{"id":"https://openalex.org/C192866977","wikidata":"https://www.wikidata.org/wiki/Q3294462","display_name":"Dynamic scraped surface heat exchanger","level":5,"score":0.5335578918457031},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.49855947494506836},{"id":"https://openalex.org/C2777777821","wikidata":"https://www.wikidata.org/wiki/Q25111513","display_name":"Heat transfer enhancement","level":4,"score":0.4962626099586487},{"id":"https://openalex.org/C204826919","wikidata":"https://www.wikidata.org/wiki/Q905855","display_name":"NTU method","level":5,"score":0.49612483382225037},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.41952207684516907},{"id":"https://openalex.org/C63257944","wikidata":"https://www.wikidata.org/wiki/Q1435974","display_name":"Regenerative heat exchanger","level":3,"score":0.41293978691101074},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.39503344893455505},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.37828952074050903},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.33372265100479126},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.3275565505027771},{"id":"https://openalex.org/C167131557","wikidata":"https://www.wikidata.org/wiki/Q5186725","display_name":"Critical heat flux","level":4,"score":0.32624882459640503},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.16592621803283691},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.15635645389556885}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3495018.3495024","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3495018.3495024","pdf_url":null,"source":{"id":"https://openalex.org/S4363607741","display_name":"2021 3rd International Conference on Artificial Intelligence and Advanced Manufacture","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2021 3rd International Conference on Artificial Intelligence and Advanced Manufacture","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W1995719151","https://openalex.org/W2018646487","https://openalex.org/W2981716240","https://openalex.org/W6739101225"],"related_works":["https://openalex.org/W4213450140","https://openalex.org/W2094644857","https://openalex.org/W1603860867","https://openalex.org/W2123472504","https://openalex.org/W2182200302","https://openalex.org/W4366570408","https://openalex.org/W3126718968","https://openalex.org/W2139214531","https://openalex.org/W4234218527","https://openalex.org/W3018723611"],"abstract_inverted_index":{"Since":[0],"the":[1,6,11,22,27,36,51,56,58,64,73,77,82,86,94,99,116,125,130,164,168,173,185],"pulsating":[2,126,179],"flow":[3,110,127,180],"will":[4,182],"affect":[5],"heat":[7,13,23,47,53,83,95,101,117,139,144,169,186],"transfer":[8,48,118,145,170],"characteristics":[9],"of":[10,17,26,30,38,68,76,81],"plate":[12,52,100],"exchanger,":[14,84],"in":[15,72,137,163],"view":[16],"its":[18,142],"ability":[19],"to":[20,92,149],"improve":[21,184],"exchange":[24,96,187],"efficiency":[25,171,188],"main":[28],"machine":[29],"various":[31],"large-scale":[32],"equipment":[33],"and":[34,85,98,112,141,155,158,167,189],"have":[35],"effect":[37],"energy":[39],"saving,":[40],"this":[41,176],"paper":[42],"conducts":[43],"a":[44,135,161],"pulsation":[45,59,107,113,131,153,165],"enhancement":[46],"study":[49],"on":[50],"exchanger.":[54],"During":[55],"experiment,":[57],"generator":[60,132],"independently":[61],"designed":[62],"by":[63,129],"Russian":[65],"State":[66],"University":[67],"Mordovia":[69],"was":[70,90,103],"installed":[71],"upstream":[74],"part":[75],"cooling":[78],"water":[79],"end":[80],"field":[87],"synergy":[88],"number":[89],"used":[91],"express":[93],"effect,":[97],"exchanger":[102],"analyzed":[104],"at":[105,175],"different":[106],"frequencies,":[108],"mass":[109,156],"rates":[111],"amplitudes.":[114],"Under":[115],"effect.":[119],"The":[120,178],"experimental":[121],"results":[122],"show":[123],"that":[124],"generated":[128],"can":[133],"play":[134],"role":[136],"enhancing":[138],"transfer,":[140],"enhanced":[143],"capacity":[146],"is":[147,160,172],"related":[148],"factors":[150],"such":[151],"as":[152],"frequency":[154],"flow;":[157],"there":[159],"peak":[162],"frequency,":[166],"highest":[174],"time.":[177],"technology":[181],"greatly":[183],"achieve":[190],"better":[191],"energy-saving":[192],"effects.":[193]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}