{"id":"https://openalex.org/W3205941417","doi":"https://doi.org/10.1145/3466752.3480098","title":"NMAP: Power Management Based on Network Packet Processing Mode Transition for Latency-Critical Workloads","display_name":"NMAP: Power Management Based on Network Packet Processing Mode Transition for Latency-Critical Workloads","publication_year":2021,"publication_date":"2021-10-17","ids":{"openalex":"https://openalex.org/W3205941417","doi":"https://doi.org/10.1145/3466752.3480098","mag":"3205941417"},"language":"en","primary_location":{"id":"doi:10.1145/3466752.3480098","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3466752.3480098","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"MICRO-54: 54th Annual IEEE/ACM International Symposium on Microarchitecture","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072540697","display_name":"Ki-Dong Kang","orcid":"https://orcid.org/0000-0002-3778-5978"},"institutions":[{"id":"https://openalex.org/I193352282","display_name":"Daegu Gyeongbuk Institute of Science and Technology","ror":"https://ror.org/03frjya69","country_code":"KR","type":"education","lineage":["https://openalex.org/I193352282"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Ki-Dong Kang","raw_affiliation_strings":["DGIST, Korea, South - Republic of Korea","DGIST, Korea, South ? Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DGIST, Korea, South - Republic of Korea","institution_ids":["https://openalex.org/I193352282"]},{"raw_affiliation_string":"DGIST, Korea, South ? Republic of Korea","institution_ids":["https://openalex.org/I193352282"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5060320492","display_name":"Gyeongseo Park","orcid":"https://orcid.org/0000-0002-9791-5447"},"institutions":[{"id":"https://openalex.org/I193352282","display_name":"Daegu Gyeongbuk Institute of Science and Technology","ror":"https://ror.org/03frjya69","country_code":"KR","type":"education","lineage":["https://openalex.org/I193352282"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Gyeongseo Park","raw_affiliation_strings":["DGIST, Korea, South - Republic of Korea","DGIST, Korea, South ? Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DGIST, Korea, South - Republic of Korea","institution_ids":["https://openalex.org/I193352282"]},{"raw_affiliation_string":"DGIST, Korea, South ? Republic of Korea","institution_ids":["https://openalex.org/I193352282"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067526066","display_name":"Hyosang Kim","orcid":"https://orcid.org/0000-0001-8140-9534"},"institutions":[{"id":"https://openalex.org/I193352282","display_name":"Daegu Gyeongbuk Institute of Science and Technology","ror":"https://ror.org/03frjya69","country_code":"KR","type":"education","lineage":["https://openalex.org/I193352282"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Hyosang Kim","raw_affiliation_strings":["DGIST"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DGIST","institution_ids":["https://openalex.org/I193352282"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069911395","display_name":"Mohammad Alian","orcid":"https://orcid.org/0000-0002-4622-2181"},"institutions":[{"id":"https://openalex.org/I146416000","display_name":"University of Kansas","ror":"https://ror.org/001tmjg57","country_code":"US","type":"education","lineage":["https://openalex.org/I146416000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Mohammad Alian","raw_affiliation_strings":["University of Kansas, United States of America"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Kansas, United States of America","institution_ids":["https://openalex.org/I146416000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037648751","display_name":"Nam Sung Kim","orcid":"https://orcid.org/0000-0002-0442-5634"},"institutions":[{"id":"https://openalex.org/I4210101778","display_name":"Samsung (United States)","ror":"https://ror.org/01bfbvm65","country_code":"US","type":"company","lineage":["https://openalex.org/I2250650973","https://openalex.org/I4210101778"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Nam Sung Kim","raw_affiliation_strings":["UIUC/Samsung, United States of America"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"UIUC/Samsung, United States of America","institution_ids":["https://openalex.org/I4210101778"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101885459","display_name":"Daehoon Kim","orcid":"https://orcid.org/0000-0003-0837-0877"},"institutions":[{"id":"https://openalex.org/I193352282","display_name":"Daegu Gyeongbuk Institute of Science and Technology","ror":"https://ror.org/03frjya69","country_code":"KR","type":"education","lineage":["https://openalex.org/I193352282"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Daehoon Kim","raw_affiliation_strings":["DGIST, Korea, South - Republic of Korea","DGIST, Korea, South ? Republic of Korea"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DGIST, Korea, South - Republic of Korea","institution_ids":["https://openalex.org/I193352282"]},{"raw_affiliation_string":"DGIST, Korea, South ? Republic of Korea","institution_ids":["https://openalex.org/I193352282"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":15,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"143","last_page":"154"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10101","display_name":"Cloud Computing and Resource Management","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1710","display_name":"Information Systems"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/packet-processing","display_name":"Packet processing","score":0.7922605872154236},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.7695633172988892},{"id":"https://openalex.org/keywords/frequency-scaling","display_name":"Frequency scaling","score":0.7181658744812012},{"id":"https://openalex.org/keywords/latency","display_name":"Latency (audio)","score":0.7114962339401245},{"id":"https://openalex.org/keywords/networking-hardware","display_name":"Networking hardware","score":0.7027404308319092},{"id":"https://openalex.org/keywords/power-management","display_name":"Power management","score":0.6986833214759827},{"id":"https://openalex.org/keywords/network-packet","display_name":"Network packet","score":0.6047711968421936},{"id":"https://openalex.org/keywords/polling","display_name":"Polling","score":0.601324737071991},{"id":"https://openalex.org/keywords/interrupt","display_name":"Interrupt","score":0.5049911141395569},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4903297424316406},{"id":"https://openalex.org/keywords/network-management","display_name":"Network management","score":0.48386991024017334},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.4639875888824463},{"id":"https://openalex.org/keywords/network-interface","display_name":"Network interface","score":0.46106085181236267},{"id":"https://openalex.org/keywords/efficient-energy-use","display_name":"Efficient energy use","score":0.4287600517272949},{"id":"https://openalex.org/keywords/software-defined-networking","display_name":"Software-defined networking","score":0.42380568385124207},{"id":"https://openalex.org/keywords/network-monitoring","display_name":"Network monitoring","score":0.41148242354393005},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.4052731394767761},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.3569648861885071},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.30928993225097656},{"id":"https://openalex.org/keywords/software","display_name":"Software","score":0.2918592095375061},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.09600415825843811}],"concepts":[{"id":"https://openalex.org/C2779581428","wikidata":"https://www.wikidata.org/wiki/Q7122997","display_name":"Packet processing","level":3,"score":0.7922605872154236},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7695633172988892},{"id":"https://openalex.org/C157742956","wikidata":"https://www.wikidata.org/wiki/Q3237776","display_name":"Frequency scaling","level":3,"score":0.7181658744812012},{"id":"https://openalex.org/C82876162","wikidata":"https://www.wikidata.org/wiki/Q17096504","display_name":"Latency (audio)","level":2,"score":0.7114962339401245},{"id":"https://openalex.org/C159631557","wikidata":"https://www.wikidata.org/wiki/Q1546066","display_name":"Networking hardware","level":2,"score":0.7027404308319092},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.6986833214759827},{"id":"https://openalex.org/C158379750","wikidata":"https://www.wikidata.org/wiki/Q214111","display_name":"Network packet","level":2,"score":0.6047711968421936},{"id":"https://openalex.org/C204854418","wikidata":"https://www.wikidata.org/wiki/Q1362921","display_name":"Polling","level":2,"score":0.601324737071991},{"id":"https://openalex.org/C41661131","wikidata":"https://www.wikidata.org/wiki/Q220764","display_name":"Interrupt","level":3,"score":0.5049911141395569},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4903297424316406},{"id":"https://openalex.org/C129763632","wikidata":"https://www.wikidata.org/wiki/Q1454667","display_name":"Network management","level":2,"score":0.48386991024017334},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.4639875888824463},{"id":"https://openalex.org/C103987645","wikidata":"https://www.wikidata.org/wiki/Q985806","display_name":"Network interface","level":3,"score":0.46106085181236267},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4287600517272949},{"id":"https://openalex.org/C77270119","wikidata":"https://www.wikidata.org/wiki/Q1655198","display_name":"Software-defined networking","level":2,"score":0.42380568385124207},{"id":"https://openalex.org/C81877898","wikidata":"https://www.wikidata.org/wiki/Q1965787","display_name":"Network monitoring","level":2,"score":0.41148242354393005},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4052731394767761},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.3569648861885071},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.30928993225097656},{"id":"https://openalex.org/C2777904410","wikidata":"https://www.wikidata.org/wiki/Q7397","display_name":"Software","level":2,"score":0.2918592095375061},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.09600415825843811},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3466752.3480098","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3466752.3480098","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"MICRO-54: 54th Annual IEEE/ACM International Symposium on Microarchitecture","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9100000262260437,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G192285908","display_name":null,"funder_award_id":"CNS-1705047","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G4278702387","display_name":null,"funder_award_id":"2014-0-00065","funder_id":"https://openalex.org/F4320335489","funder_display_name":"Institute for Information and Communications Technology Promotion"},{"id":"https://openalex.org/G8977047691","display_name":null,"funder_award_id":"NRF-2020R1C1C1013315, NRF-2018R1A5A1060031","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"},{"id":"https://openalex.org/F4320335489","display_name":"Institute for Information and Communications Technology Promotion","ror":"https://ror.org/01g0hqq23"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W1600369258","https://openalex.org/W1982063824","https://openalex.org/W2014485836","https://openalex.org/W2023214828","https://openalex.org/W2050974892","https://openalex.org/W2061574886","https://openalex.org/W2061884403","https://openalex.org/W2072861102","https://openalex.org/W2086724906","https://openalex.org/W2098395496","https://openalex.org/W2100346277","https://openalex.org/W2126584218","https://openalex.org/W2127748654","https://openalex.org/W2134807578","https://openalex.org/W2138574538","https://openalex.org/W2150139096","https://openalex.org/W2156077332","https://openalex.org/W2160121678","https://openalex.org/W2235495043","https://openalex.org/W2236373029","https://openalex.org/W2324132005","https://openalex.org/W2488753447","https://openalex.org/W2560047851","https://openalex.org/W2597880136","https://openalex.org/W2612225380","https://openalex.org/W2626985503","https://openalex.org/W2925744458","https://openalex.org/W2926143647","https://openalex.org/W2967018380","https://openalex.org/W3094668235","https://openalex.org/W3096858084","https://openalex.org/W4231427385","https://openalex.org/W4241251112"],"related_works":["https://openalex.org/W3205941417","https://openalex.org/W1971358294","https://openalex.org/W2156114432","https://openalex.org/W1603711496","https://openalex.org/W2770733137","https://openalex.org/W1593892783","https://openalex.org/W4214772975","https://openalex.org/W1794141609","https://openalex.org/W2322853118","https://openalex.org/W3002749125"],"abstract_inverted_index":{"Processor":[0],"power":[1,25,57,91,117,183],"management":[2,26,58,92,118,184],"exploiting":[3,94],"Dynamic":[4],"Voltage":[5],"and":[6,46,64,85,125,140,151,166,174,180],"Frequency":[7],"Scaling":[8],"(DVFS)":[9],"plays":[10],"a":[11,40,90],"crucial":[12],"role":[13],"in":[14,28,76,100,127],"improving":[15],"the":[16,53,66,73,79,83,101,107,111,121,128,138,144,149],"data-center\u2019s":[17],"energy":[18,47,168],"efficiency.":[19],"However,":[20],"we":[21,88],"observe":[22],"that":[23,68,159],"current":[24],"policies":[27,59],"Linux":[29,178],"(i.e.,":[30,38],"governors)":[31],"often":[32],"considerably":[33],"increase":[34],"tail":[35],"response":[36],"time":[37],"violate":[39,164],"given":[41],"Service":[42],"Level":[43],"Objective":[44],"(SLO))":[45],"consumption":[48,169],"of":[49],"latency-critical":[50],"applications.":[51],"Furthermore,":[52],"previously":[54],"proposed":[55,116],"SLO-aware":[56,182],"oversimplify":[60],"network":[61,69,86,95,113,129],"request":[62],"processing":[63,97,108,136],"ignore":[65],"fact":[67],"requests":[70],"arrive":[71],"at":[72],"application":[74],"layer":[75],"bursts.":[77],"Considering":[78],"complex":[80],"interplay":[81],"between":[82,123],"OS":[84,102],"devices,":[87],"propose":[89],"framework":[93,119,161],"packet":[96,135],"mode":[98],"transitions":[99,122],"to":[103,106,132,143,172,177],"quickly":[104],"react":[105,142],"demands":[109],"from":[110],"received":[112],"requests.":[114],"Our":[115,155],"tracks":[120],"polling":[124],"interrupt":[126],"software":[130],"stack":[131],"detect":[133],"excessive":[134],"on":[137],"cores":[139],"immediately":[141],"load":[145],"changes":[146],"by":[147,170],"updating":[148],"voltage":[150],"frequency":[152],"(V/F)":[153],"states.":[154],"experimental":[156],"results":[157],"show":[158],"our":[160],"does":[162],"not":[163],"SLO":[165],"reduces":[167],"up":[171],"35.7%":[173],"14.8%":[175],"compared":[176],"governors":[179],"state-of-the-art":[181],"techniques,":[185],"respectively.":[186]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":2}],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}
