{"id":"https://openalex.org/W3162791612","doi":"https://doi.org/10.1145/3452940.3453005","title":"Simulation Study on Electromagnetic Loss and Temperature Rise of Dry Type Air Reactor on Steel Buildings","display_name":"Simulation Study on Electromagnetic Loss and Temperature Rise of Dry Type Air Reactor on Steel Buildings","publication_year":2020,"publication_date":"2020-12-03","ids":{"openalex":"https://openalex.org/W3162791612","doi":"https://doi.org/10.1145/3452940.3453005","mag":"3162791612"},"language":"en","primary_location":{"id":"doi:10.1145/3452940.3453005","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3452940.3453005","pdf_url":null,"source":{"id":"https://openalex.org/S4306523813","display_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100461491","display_name":"Liming Zhang","orcid":"https://orcid.org/0000-0003-1497-1556"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liming Zhang","raw_affiliation_strings":["State Grid Tianjin Electric Power Company, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Grid Tianjin Electric Power Company, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101205914","display_name":"Jin He","orcid":null},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jin He","raw_affiliation_strings":["State grid tianjin electric power research institute, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State grid tianjin electric power research institute, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003435098","display_name":"Qiong Fang","orcid":"https://orcid.org/0000-0001-6644-9861"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qiong Fang","raw_affiliation_strings":["State grid tianjin electric power research institute, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State grid tianjin electric power research institute, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100419031","display_name":"Rong Chen","orcid":"https://orcid.org/0000-0002-8680-184X"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Rong Chen","raw_affiliation_strings":["State grid tianjin electric power research institute, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State grid tianjin electric power research institute, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5061837198","display_name":"Yuyan Man","orcid":null},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yuyan Man","raw_affiliation_strings":["State grid tianjin electric power research institute, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State grid tianjin electric power research institute, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040468629","display_name":"Xu-Liang Zhu","orcid":"https://orcid.org/0000-0001-5976-8493"},"institutions":[{"id":"https://openalex.org/I4210097143","display_name":"Tianjin Research Institute of Electric Science (China)","ror":"https://ror.org/010ryc044","country_code":"CN","type":"company","lineage":["https://openalex.org/I4210097143"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xuliang Zhu","raw_affiliation_strings":["State grid tianjin electric power research institute, Tianjin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State grid tianjin electric power research institute, Tianjin, China","institution_ids":["https://openalex.org/I4210097143"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210097143"],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"337","last_page":"342"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12163","display_name":"Aerosol Filtration and Electrostatic Precipitation","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/eddy-current","display_name":"Eddy current","score":0.7502045631408691},{"id":"https://openalex.org/keywords/conductor","display_name":"Conductor","score":0.6851174235343933},{"id":"https://openalex.org/keywords/joule-heating","display_name":"Joule heating","score":0.6145835518836975},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6023916602134705},{"id":"https://openalex.org/keywords/joule","display_name":"Joule (programming language)","score":0.5906482338905334},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.513531506061554},{"id":"https://openalex.org/keywords/electrical-conductor","display_name":"Electrical conductor","score":0.470350056886673},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.4650823473930359},{"id":"https://openalex.org/keywords/electromagnetic-field","display_name":"Electromagnetic field","score":0.4346276819705963},{"id":"https://openalex.org/keywords/nuclear-engineering","display_name":"Nuclear engineering","score":0.4142938256263733},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2914184629917145},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.19532668590545654},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1836109161376953},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.17399826645851135}],"concepts":[{"id":"https://openalex.org/C131357438","wikidata":"https://www.wikidata.org/wiki/Q208598","display_name":"Eddy current","level":2,"score":0.7502045631408691},{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.6851174235343933},{"id":"https://openalex.org/C117926987","wikidata":"https://www.wikidata.org/wiki/Q210009","display_name":"Joule heating","level":2,"score":0.6145835518836975},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6023916602134705},{"id":"https://openalex.org/C2779058145","wikidata":"https://www.wikidata.org/wiki/Q6294583","display_name":"Joule (programming language)","level":3,"score":0.5906482338905334},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.513531506061554},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.470350056886673},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.4650823473930359},{"id":"https://openalex.org/C28843909","wikidata":"https://www.wikidata.org/wiki/Q177625","display_name":"Electromagnetic field","level":2,"score":0.4346276819705963},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4142938256263733},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2914184629917145},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.19532668590545654},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1836109161376953},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.17399826645851135},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3452940.3453005","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3452940.3453005","pdf_url":null,"source":{"id":"https://openalex.org/S4306523813","display_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2071393212","https://openalex.org/W2122971703","https://openalex.org/W2153853603","https://openalex.org/W2286343138","https://openalex.org/W2589152713","https://openalex.org/W4232156911"],"related_works":["https://openalex.org/W2373989821","https://openalex.org/W114754765","https://openalex.org/W1985250799","https://openalex.org/W2007883630","https://openalex.org/W2089851417","https://openalex.org/W3120473554","https://openalex.org/W3094583181","https://openalex.org/W2164412452","https://openalex.org/W2111960134","https://openalex.org/W2034139904"],"abstract_inverted_index":{"The":[0,58],"changing":[1],"magnetic":[2,41,81],"field":[3,42,82],"of":[4,30,49,66,86,106,121,130],"air":[5],"reactor":[6,74],"will":[7,21],"cause":[8,22],"additional":[9],"electromagnetic":[10],"loss":[11],"and":[12,39,62,137],"eddy":[13,59],"current":[14,60],"effect":[15],"on":[16,26],"the":[17,27,32,40,67,73,79,84,90,97,103,107,111,117,122,127,131,135,138],"surrounding":[18],"conductor,":[19],"which":[20],"temperature":[23,104,113,119,140],"rise.":[24],"Based":[25],"actual":[28],"structure":[29],"reactor,":[31,136],"three-dimensional":[33],"numerical":[34],"modeling":[35],"is":[36,56,94,114],"carried":[37],"out,":[38],"distribution":[43,61,65],"within":[44],"50m":[45],"around":[46],"three":[47],"groups":[48],"three-phase":[50],"reactors":[51],"arranged":[52],"in":[53,126],"zigzag":[54],"configuration":[55],"simulated.":[57],"Joule":[63,92],"heat":[64,93,99],"steel":[68,108],"house":[69,124,132],"11.25m":[70],"away":[71],"from":[72],"center":[75],"are":[76],"obtained":[77],"under":[78],"varying":[80],"at":[83],"frequency":[85],"50":[87],"Hz.":[88],"Finally,":[89],"calculated":[91],"used":[95],"as":[96],"volume":[98],"source":[100],"to":[101,134],"analyze":[102],"rise":[105,120,141],"house.":[109],"When":[110],"ambient":[112],"20":[115],"\u00b0C,":[116],"maximum":[118,139],"whole":[123],"appears":[125],"front":[128],"wall":[129],"close":[133],"can":[142],"reach":[143],"6.988":[144],"\u00b0C.":[145]},"counts_by_year":[],"updated_date":"2026-07-14T23:27:15.235271","created_date":"2025-10-10T00:00:00"}