{"id":"https://openalex.org/W3160520761","doi":"https://doi.org/10.1145/3452940.3452988","title":"Root Cause of Anode Reactor Failure in HVDC Project","display_name":"Root Cause of Anode Reactor Failure in HVDC Project","publication_year":2020,"publication_date":"2020-12-03","ids":{"openalex":"https://openalex.org/W3160520761","doi":"https://doi.org/10.1145/3452940.3452988","mag":"3160520761"},"language":"en","primary_location":{"id":"doi:10.1145/3452940.3452988","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3452940.3452988","pdf_url":null,"source":{"id":"https://openalex.org/S4306523813","display_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055119386","display_name":"Ning Liang","orcid":"https://orcid.org/0000-0003-3153-6820"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Ning Liang","raw_affiliation_strings":["China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China"],"affiliations":[{"raw_affiliation_string":"China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032213183","display_name":"Cien Liu","orcid":null},"institutions":[{"id":"https://openalex.org/I139024713","display_name":"Guangdong University of Technology","ror":"https://ror.org/04azbjn80","country_code":"CN","type":"education","lineage":["https://openalex.org/I139024713"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Cien Liu","raw_affiliation_strings":["School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou Guangdong China"],"affiliations":[{"raw_affiliation_string":"School of Chemical Engineering and Light Industry, Guangdong University of Technology, Guangzhou Guangdong China","institution_ids":["https://openalex.org/I139024713"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100398813","display_name":"Kun Liu","orcid":"https://orcid.org/0000-0003-3739-3234"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kun Liu","raw_affiliation_strings":["China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China"],"affiliations":[{"raw_affiliation_string":"China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100422268","display_name":"Zhen Wang","orcid":"https://orcid.org/0000-0001-7188-5828"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhen Wang","raw_affiliation_strings":["China Southern Power Grid EHV Maintenance &amp; Test Center, China"],"affiliations":[{"raw_affiliation_string":"China Southern Power Grid EHV Maintenance &amp; Test Center, China","institution_ids":["https://openalex.org/I74872605"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019901854","display_name":"Yansheng Zou","orcid":"https://orcid.org/0000-0002-6805-772X"},"institutions":[{"id":"https://openalex.org/I74872605","display_name":"China Southern Power Grid (China)","ror":"https://ror.org/03hkh9419","country_code":"CN","type":"company","lineage":["https://openalex.org/I74872605"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yansheng Zou","raw_affiliation_strings":["China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China"],"affiliations":[{"raw_affiliation_string":"China Southern Power Grid EHV, Power Transmission Company, Maintenance &amp; Test Center, Science Avenue, Guangzhou, China","institution_ids":["https://openalex.org/I74872605"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5055119386"],"corresponding_institution_ids":["https://openalex.org/I74872605"],"apc_list":null,"apc_paid":null,"fwci":0.4623,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.61694915,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"246","last_page":"249"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9972000122070312,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9724000096321106,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9682999849319458,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/anode","display_name":"Anode","score":0.9201090931892395},{"id":"https://openalex.org/keywords/nuclear-engineering","display_name":"Nuclear engineering","score":0.6758868098258972},{"id":"https://openalex.org/keywords/root-cause","display_name":"Root cause","score":0.6379081606864929},{"id":"https://openalex.org/keywords/root-cause-analysis","display_name":"Root cause analysis","score":0.547989010810852},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4839089810848236},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.36097025871276855},{"id":"https://openalex.org/keywords/waste-management","display_name":"Waste management","score":0.32821500301361084},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3205024003982544},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.26825106143951416},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.19204935431480408},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.1694425344467163}],"concepts":[{"id":"https://openalex.org/C89395315","wikidata":"https://www.wikidata.org/wiki/Q181232","display_name":"Anode","level":3,"score":0.9201090931892395},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.6758868098258972},{"id":"https://openalex.org/C84945661","wikidata":"https://www.wikidata.org/wiki/Q7366567","display_name":"Root cause","level":2,"score":0.6379081606864929},{"id":"https://openalex.org/C130963320","wikidata":"https://www.wikidata.org/wiki/Q1401207","display_name":"Root cause analysis","level":2,"score":0.547989010810852},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4839089810848236},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.36097025871276855},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.32821500301361084},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3205024003982544},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26825106143951416},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.19204935431480408},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.1694425344467163},{"id":"https://openalex.org/C147789679","wikidata":"https://www.wikidata.org/wiki/Q11372","display_name":"Physical chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3452940.3452988","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3452940.3452988","pdf_url":null,"source":{"id":"https://openalex.org/S4306523813","display_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W2174049689","https://openalex.org/W2775299473","https://openalex.org/W2783886498","https://openalex.org/W2977692878"],"related_works":["https://openalex.org/W3005087358","https://openalex.org/W2141950192","https://openalex.org/W1984885591","https://openalex.org/W141106878","https://openalex.org/W1988621644","https://openalex.org/W2210812206","https://openalex.org/W2346194807","https://openalex.org/W2005264349","https://openalex.org/W2078644205","https://openalex.org/W4236466767"],"abstract_inverted_index":{"The":[0],"anode":[1,20,44],"reactor":[2,21,45],"plays":[3],"an":[4],"important":[5],"role":[6],"in":[7],"the":[8,19,29,43,49,53,59],"HVDC":[9,35],"converter":[10],"valve,":[11],"but":[12],"after":[13],"nearly":[14],"ten":[15],"years":[16],"of":[17,34,42,52],"operation,":[18],"failure":[22,54,64],"occurs":[23],"for":[24],"several":[25],"times,":[26],"which":[27],"affects":[28],"safe":[30],"and":[31,58],"reliable":[32],"operation":[33],"projects.":[36],"This":[37],"paper":[38],"analysis":[39],"one":[40],"case":[41],"over":[46],"heat":[47],"failure,":[48],"root":[50],"cause":[51],"is":[55,65],"carried":[56],"out":[57],"measures":[60],"to":[61],"prevent":[62],"similar":[63],"present.":[66]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
