{"id":"https://openalex.org/W3131282589","doi":"https://doi.org/10.1145/3448218.3448242","title":"Numerical Study on Magnetic Field Characteristics of Electromagnetic Flowmeter with Small Excitation Module","display_name":"Numerical Study on Magnetic Field Characteristics of Electromagnetic Flowmeter with Small Excitation Module","publication_year":2021,"publication_date":"2021-01-14","ids":{"openalex":"https://openalex.org/W3131282589","doi":"https://doi.org/10.1145/3448218.3448242","mag":"3131282589"},"language":"en","primary_location":{"id":"doi:10.1145/3448218.3448242","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3448218.3448242","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Conference on Control Engineering and Artificial Intelligence","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5066224029","display_name":"Xinhong Yao","orcid":null},"institutions":[{"id":"https://openalex.org/I4210105460","display_name":"Shanghai Institute of Measurement and Testing Technology","ror":"https://ror.org/00zcefp03","country_code":"CN","type":"nonprofit","lineage":["https://openalex.org/I4210105460"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Xinhong Yao","raw_affiliation_strings":["Shanghai Institute of Measurement and Testing Technology and Shanghai Key Laboratory of On-line Testing and Control Technology"],"affiliations":[{"raw_affiliation_string":"Shanghai Institute of Measurement and Testing Technology and Shanghai Key Laboratory of On-line Testing and Control Technology","institution_ids":["https://openalex.org/I4210105460"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100628868","display_name":"Xuejing Li","orcid":"https://orcid.org/0000-0003-1493-3576"},"institutions":[{"id":"https://openalex.org/I4210105460","display_name":"Shanghai Institute of Measurement and Testing Technology","ror":"https://ror.org/00zcefp03","country_code":"CN","type":"nonprofit","lineage":["https://openalex.org/I4210105460"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xuejing Li","raw_affiliation_strings":["Shanghai Institute of Measurement and Testing Technology and Shanghai Key Laboratory of On-line Testing and Control Technology"],"affiliations":[{"raw_affiliation_string":"Shanghai Institute of Measurement and Testing Technology and Shanghai Key Laboratory of On-line Testing and Control Technology","institution_ids":["https://openalex.org/I4210105460"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5066224029"],"corresponding_institution_ids":["https://openalex.org/I4210105460"],"apc_list":null,"apc_paid":null,"fwci":0.4399,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.5340098,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":null,"issue":null,"first_page":"86","last_page":"89"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9887999892234802,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.987500011920929,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.7205025553703308},{"id":"https://openalex.org/keywords/helmholtz-coil","display_name":"Helmholtz coil","score":0.6703450679779053},{"id":"https://openalex.org/keywords/electromagnetic-field","display_name":"Electromagnetic field","score":0.659125566482544},{"id":"https://openalex.org/keywords/excitation","display_name":"Excitation","score":0.6406224966049194},{"id":"https://openalex.org/keywords/magnetic-flow-meter","display_name":"Magnetic flow meter","score":0.6022265553474426},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.5970293283462524},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.5061082243919373},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.5030724406242371},{"id":"https://openalex.org/keywords/saddle","display_name":"Saddle","score":0.46474358439445496},{"id":"https://openalex.org/keywords/electromagnetics","display_name":"Electromagnetics","score":0.4540407061576843},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.39271387457847595},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.36851710081100464},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3639804422855377},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.339735209941864},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.32809072732925415},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.2848597764968872}],"concepts":[{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.7205025553703308},{"id":"https://openalex.org/C2778252132","wikidata":"https://www.wikidata.org/wiki/Q1603273","display_name":"Helmholtz coil","level":3,"score":0.6703450679779053},{"id":"https://openalex.org/C28843909","wikidata":"https://www.wikidata.org/wiki/Q177625","display_name":"Electromagnetic field","level":2,"score":0.659125566482544},{"id":"https://openalex.org/C83581075","wikidata":"https://www.wikidata.org/wiki/Q1361503","display_name":"Excitation","level":2,"score":0.6406224966049194},{"id":"https://openalex.org/C27805115","wikidata":"https://www.wikidata.org/wiki/Q960824","display_name":"Magnetic flow meter","level":3,"score":0.6022265553474426},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.5970293283462524},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.5061082243919373},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.5030724406242371},{"id":"https://openalex.org/C2777127463","wikidata":"https://www.wikidata.org/wiki/Q10862618","display_name":"Saddle","level":2,"score":0.46474358439445496},{"id":"https://openalex.org/C2909720056","wikidata":"https://www.wikidata.org/wiki/Q11406","display_name":"Electromagnetics","level":2,"score":0.4540407061576843},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.39271387457847595},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.36851710081100464},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3639804422855377},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.339735209941864},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.32809072732925415},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.2848597764968872},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3448218.3448242","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3448218.3448242","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Conference on Control Engineering and Artificial Intelligence","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5699999928474426,"id":"https://metadata.un.org/sdg/2","display_name":"Zero hunger"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1988664842","https://openalex.org/W2004242950","https://openalex.org/W2095010139","https://openalex.org/W2148219078","https://openalex.org/W2614551502","https://openalex.org/W2986554476"],"related_works":["https://openalex.org/W2057718659","https://openalex.org/W2038672343","https://openalex.org/W4386246496","https://openalex.org/W2016205572","https://openalex.org/W1673424278","https://openalex.org/W149282643","https://openalex.org/W2378501682","https://openalex.org/W4244958415","https://openalex.org/W2317052444","https://openalex.org/W626106120"],"abstract_inverted_index":{"Electromagnetic":[0],"flowmeter":[1,25,113,149],"(EMFM)":[2],"plays":[3],"an":[4],"important":[5],"role":[6],"in":[7,55,81],"many":[8],"production":[9],"processes":[10],"such":[11],"as":[12],"industry,":[13],"medicine":[14],"and":[15,72,116],"agriculture.":[16],"According":[17],"to":[18,32],"the":[19,22,42,63,69,87,90,96,119,127,143,147],"measurement":[20,97],"principle,":[21],"traditional":[23],"electromagnetic":[24,45,56,123,148],"must":[26],"have":[27,138],"a":[28,34,102,110],"large-size":[29],"excitation":[30,104,150],"module":[31],"provide":[33],"uniform":[35],"magnetic":[36,92],"field.":[37],"However,":[38],"this":[39,136],"structure":[40],"limits":[41],"use":[43],"of":[44,62,89,126,135,146],"flow":[46,57],"meters.":[47],"The":[48,59,122,133],"saddle":[49,64],"coil":[50,65,71],"design":[51,144],"has":[52,78],"certain":[53,79,139],"applications":[54],"sensors.":[58],"geometric":[60],"size":[61],"is":[66,114,131],"smaller":[67],"than":[68],"Helmholtz":[70],"other":[73],"large":[74],"coils,":[75],"so":[76],"it":[77,85],"advantages":[80],"practical":[82],"applications.":[83],"But":[84],"causes":[86],"inhomogeneity":[88],"induced":[91],"field,":[93],"which":[94],"affects":[95],"accuracy.":[98],"This":[99],"paper":[100],"analyzes":[101],"saddle-shaped":[103],"module.":[105],"An":[106],"extended":[107],"theory":[108],"with":[109,118],"small":[111],"magnetized":[112],"proposed":[115],"compared":[117],"experimental":[120],"results.":[121],"field":[124],"solution":[125],"finite":[128],"element":[129],"program":[130],"proposed.":[132],"results":[134],"study":[137],"guiding":[140],"significance":[141],"for":[142],"process":[145],"coil.":[151]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}