{"id":"https://openalex.org/W3161457873","doi":"https://doi.org/10.1145/3447555.3466582","title":"A Guide to Reducing Carbon Emissions through Data Center Geographical Load Shifting","display_name":"A Guide to Reducing Carbon Emissions through Data Center Geographical Load Shifting","publication_year":2021,"publication_date":"2021-06-22","ids":{"openalex":"https://openalex.org/W3161457873","doi":"https://doi.org/10.1145/3447555.3466582","mag":"3161457873"},"language":"en","primary_location":{"id":"doi:10.1145/3447555.3466582","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3447555.3466582","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Twelfth ACM International Conference on Future Energy Systems","raw_type":"proceedings-article"},"type":"preprint","indexed_in":["arxiv","crossref","datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2105.09120","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055721131","display_name":"Julia Lindberg","orcid":"https://orcid.org/0000-0002-6840-6053"},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Julia Lindberg","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065953830","display_name":"Yasmine Abdennadher","orcid":null},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yasmine Abdennadher","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100434211","display_name":"Jiaqi Chen","orcid":"https://orcid.org/0009-0009-9747-1610"},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jiaqi Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5110239075","display_name":"Bernard C. Lesieutre","orcid":null},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bernard C. Lesieutre","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5005034793","display_name":"Line Roald","orcid":"https://orcid.org/0000-0003-4378-7272"},"institutions":[{"id":"https://openalex.org/I135310074","display_name":"University of Wisconsin\u2013Madison","ror":"https://ror.org/01y2jtd41","country_code":"US","type":"education","lineage":["https://openalex.org/I135310074"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Line Roald","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]},{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Wisconsin - Madison, Madison, Wisconsin, USA","institution_ids":["https://openalex.org/I135310074"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5055721131"],"corresponding_institution_ids":["https://openalex.org/I135310074"],"apc_list":null,"apc_paid":null,"fwci":0.1016,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.41443133,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"430","last_page":"436"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9945999979972839,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10715","display_name":"Distributed and Parallel Computing Systems","score":0.991100013256073,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9879999756813049,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/flexibility","display_name":"Flexibility (engineering)","score":0.6689860820770264},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.6565356850624084},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.6024748086929321},{"id":"https://openalex.org/keywords/metric","display_name":"Metric (unit)","score":0.5145356059074402},{"id":"https://openalex.org/keywords/environmental-economics","display_name":"Environmental economics","score":0.4700034260749817},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4602029025554657},{"id":"https://openalex.org/keywords/process","display_name":"Process (computing)","score":0.4582774341106415},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.4449809193611145},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.4283742308616638},{"id":"https://openalex.org/keywords/greenhouse-gas","display_name":"Greenhouse gas","score":0.4111729860305786},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.3891146183013916},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.22383847832679749},{"id":"https://openalex.org/keywords/geography","display_name":"Geography","score":0.2163672149181366},{"id":"https://openalex.org/keywords/operations-management","display_name":"Operations management","score":0.18420907855033875},{"id":"https://openalex.org/keywords/economics","display_name":"Economics","score":0.15718194842338562},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.14066413044929504},{"id":"https://openalex.org/keywords/ecology","display_name":"Ecology","score":0.08696249127388}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.6689860820770264},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.6565356850624084},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6024748086929321},{"id":"https://openalex.org/C176217482","wikidata":"https://www.wikidata.org/wiki/Q860554","display_name":"Metric (unit)","level":2,"score":0.5145356059074402},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.4700034260749817},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4602029025554657},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.4582774341106415},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.4449809193611145},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.4283742308616638},{"id":"https://openalex.org/C47737302","wikidata":"https://www.wikidata.org/wiki/Q167336","display_name":"Greenhouse gas","level":2,"score":0.4111729860305786},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3891146183013916},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.22383847832679749},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.2163672149181366},{"id":"https://openalex.org/C21547014","wikidata":"https://www.wikidata.org/wiki/Q1423657","display_name":"Operations management","level":1,"score":0.18420907855033875},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.15718194842338562},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.14066413044929504},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.08696249127388},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C187736073","wikidata":"https://www.wikidata.org/wiki/Q2920921","display_name":"Management","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C13280743","wikidata":"https://www.wikidata.org/wiki/Q131089","display_name":"Geodesy","level":1,"score":0.0}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1145/3447555.3466582","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3447555.3466582","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Twelfth ACM International Conference on Future Energy Systems","raw_type":"proceedings-article"},{"id":"pmh:oai:arXiv.org:2105.09120","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2105.09120","pdf_url":"https://arxiv.org/pdf/2105.09120","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"mag:3161457873","is_oa":true,"landing_page_url":"https://arxiv.org/pdf/2105.09120.pdf","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"arXiv (Cornell University)","raw_type":null},{"id":"doi:10.48550/arxiv.2105.09120","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2105.09120","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2105.09120","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2105.09120","pdf_url":"https://arxiv.org/pdf/2105.09120","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G5954070948","display_name":null,"funder_award_id":"CMMI-","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"},{"id":"https://openalex.org/G7247871865","display_name":null,"funder_award_id":"1832208","funder_id":"https://openalex.org/F4320306076","funder_display_name":"National Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320306076","display_name":"National Science Foundation","ror":"https://ror.org/021nxhr62"},{"id":"https://openalex.org/F4320337391","display_name":"Division of Civil, Mechanical and Manufacturing Innovation","ror":"https://ror.org/028yd4c30"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3161457873.pdf","grobid_xml":"https://content.openalex.org/works/W3161457873.grobid-xml"},"referenced_works_count":32,"referenced_works":["https://openalex.org/W1556107429","https://openalex.org/W1966090033","https://openalex.org/W1966592513","https://openalex.org/W1973100921","https://openalex.org/W1991971657","https://openalex.org/W1996600352","https://openalex.org/W2028964022","https://openalex.org/W2036001459","https://openalex.org/W2082034273","https://openalex.org/W2102626318","https://openalex.org/W2102910133","https://openalex.org/W2106836195","https://openalex.org/W2107128713","https://openalex.org/W2116364029","https://openalex.org/W2191741352","https://openalex.org/W2290302531","https://openalex.org/W2486341861","https://openalex.org/W2522871288","https://openalex.org/W2621092124","https://openalex.org/W2744637211","https://openalex.org/W2774482637","https://openalex.org/W2900729255","https://openalex.org/W2908532574","https://openalex.org/W2953900930","https://openalex.org/W2964101724","https://openalex.org/W3007855629","https://openalex.org/W3031279185","https://openalex.org/W3049645143","https://openalex.org/W3080927554","https://openalex.org/W3092386667","https://openalex.org/W3127874816","https://openalex.org/W3129160967"],"related_works":["https://openalex.org/W2218546268","https://openalex.org/W194077722","https://openalex.org/W2775898748","https://openalex.org/W2068858716","https://openalex.org/W3028204518","https://openalex.org/W3119661721","https://openalex.org/W2778004953","https://openalex.org/W2004656206","https://openalex.org/W2794967692","https://openalex.org/W2545205673","https://openalex.org/W3095150120","https://openalex.org/W2901575074","https://openalex.org/W2797813746","https://openalex.org/W3156317651","https://openalex.org/W3118363156","https://openalex.org/W2537019988","https://openalex.org/W2997444654","https://openalex.org/W2426206800","https://openalex.org/W3171354601","https://openalex.org/W3125014539"],"abstract_inverted_index":{"Recent":[0],"computing":[1],"needs":[2],"have":[3,26],"lead":[4],"technology":[5],"companies":[6],"to":[7,30,50,101,109,128],"develop":[8],"large":[9,19],"scale,":[10],"highly":[11],"optimized":[12],"data":[13,16,42],"centers.":[14],"These":[15],"centers":[17,43],"represent":[18],"loads":[20],"on":[21,40,125],"electric":[22,73],"power":[23,68,167],"networks":[24],"which":[25,106],"the":[27,72,75,111,136,163,166],"unique":[28],"flexibility":[29,49],"shift":[31],"load":[32,48,104],"both":[33],"geographically":[34,85],"and":[35,67,98,120,132],"temporally.":[36],"This":[37],"paper":[38],"focuses":[39],"how":[41],"can":[44],"use":[45,81],"their":[46,126],"geographic":[47,103],"reduce":[51,129],"carbon":[52,76,114,130,151],"emissions":[53,77,131,152],"through":[54],"clever":[55],"interactions":[56],"with":[57,79],"electricity":[58,61,80],"markets.":[59],"Because":[60],"market":[62],"clearing":[63],"accounts":[64],"for":[65,162],"congestion":[66],"flow":[69],"physics":[70],"in":[71,149],"grid,":[74],"associated":[78],"varies":[82],"between":[83],"(potentially":[84],"close)":[86],"locations.":[87],"Using":[88],"our":[89],"knowledge":[90],"about":[91],"this":[92,119],"process,":[93],"we":[94,107],"propose":[95],"a":[96,139],"new":[97],"improved":[99],"metric":[100],"guide":[102],"shifting,":[105],"refer":[108],"as":[110],"locational":[112],"marginal":[113],"emission":[115],"\u03bbCO2.":[116],"We":[117],"compare":[118],"three":[121],"other":[122],"shifting":[123],"metrics":[124,157],"ability":[127],"generation":[133],"costs":[134],"throughout":[135],"course":[137],"of":[138,165],"year.":[140],"Our":[141],"analysis":[142],"demonstrates":[143],"that":[144,158],"\u03bbCO2":[145],"is":[146],"more":[147,154],"effective":[148],"reducing":[150],"than":[153],"commonly":[155],"proposed":[156],"do":[159],"not":[160],"account":[161],"specifics":[164],"grid.":[168]},"counts_by_year":[{"year":2022,"cited_by_count":1}],"updated_date":"2026-04-21T08:09:41.155169","created_date":"2025-10-10T00:00:00"}
