{"id":"https://openalex.org/W3107013659","doi":"https://doi.org/10.1145/3427771.3427854","title":"Energy Disaggregation for Small and Medium Businesses and their Operational Characteristics","display_name":"Energy Disaggregation for Small and Medium Businesses and their Operational Characteristics","publication_year":2020,"publication_date":"2020-11-18","ids":{"openalex":"https://openalex.org/W3107013659","doi":"https://doi.org/10.1145/3427771.3427854","mag":"3107013659"},"language":"en","primary_location":{"id":"doi:10.1145/3427771.3427854","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3427771.3427854","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Workshop on Non-Intrusive Load Monitoring","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101961676","display_name":"Abhinav Srivastava","orcid":"https://orcid.org/0000-0003-4995-2646"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Abhinav Srivastava","raw_affiliation_strings":["Bidgely Technologies, Bangalore, Karnataka-India"],"affiliations":[{"raw_affiliation_string":"Bidgely Technologies, Bangalore, Karnataka-India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026833417","display_name":"Paras Tehria","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Paras Tehria","raw_affiliation_strings":["Bidgely Technologies, Bangalore, Karnataka-India"],"affiliations":[{"raw_affiliation_string":"Bidgely Technologies, Bangalore, Karnataka-India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5021444512","display_name":"Basant K. Pandey","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Basant K. Pandey","raw_affiliation_strings":["Bidgely Technologies, Bangalore, Karnataka-India"],"affiliations":[{"raw_affiliation_string":"Bidgely Technologies, Bangalore, Karnataka-India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5101961676"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1027,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.44540328,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"59","last_page":"63"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11980","display_name":"Human Mobility and Location-Based Analysis","score":0.9671000242233276,"subfield":{"id":"https://openalex.org/subfields/3313","display_name":"Transportation"},"field":{"id":"https://openalex.org/fields/33","display_name":"Social Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T10444","display_name":"Context-Aware Activity Recognition Systems","score":0.9652000069618225,"subfield":{"id":"https://openalex.org/subfields/1707","display_name":"Computer Vision and Pattern Recognition"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/scalability","display_name":"Scalability","score":0.7031931281089783},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6875953674316406},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.5222978591918945},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.4833623766899109},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.47117525339126587},{"id":"https://openalex.org/keywords/limit","display_name":"Limit (mathematics)","score":0.45438018441200256},{"id":"https://openalex.org/keywords/domain","display_name":"Domain (mathematical analysis)","score":0.4543229937553406},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4476281702518463},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.42792755365371704},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3268253207206726},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.2345803678035736},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.077450692653656}],"concepts":[{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.7031931281089783},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6875953674316406},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.5222978591918945},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.4833623766899109},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.47117525339126587},{"id":"https://openalex.org/C151201525","wikidata":"https://www.wikidata.org/wiki/Q177239","display_name":"Limit (mathematics)","level":2,"score":0.45438018441200256},{"id":"https://openalex.org/C36503486","wikidata":"https://www.wikidata.org/wiki/Q11235244","display_name":"Domain (mathematical analysis)","level":2,"score":0.4543229937553406},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4476281702518463},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.42792755365371704},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3268253207206726},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.2345803678035736},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.077450692653656},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C134306372","wikidata":"https://www.wikidata.org/wiki/Q7754","display_name":"Mathematical analysis","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3427771.3427854","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3427771.3427854","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 5th International Workshop on Non-Intrusive Load Monitoring","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8999999761581421}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2010314082","https://openalex.org/W2045247177","https://openalex.org/W2046308864","https://openalex.org/W2165856210","https://openalex.org/W2784750963","https://openalex.org/W2891474533"],"related_works":["https://openalex.org/W2389214306","https://openalex.org/W4235240664","https://openalex.org/W2965083567","https://openalex.org/W1838576100","https://openalex.org/W2095886385","https://openalex.org/W1968767884","https://openalex.org/W2150802979","https://openalex.org/W2356819012","https://openalex.org/W4391423612","https://openalex.org/W2008521473"],"abstract_inverted_index":{"Small":[0],"and":[1,40,48,57],"Medium":[2],"Businesses":[3],"(SMBs)":[4],"make":[5],"up":[6],"a":[7,65],"large":[8],"chunk":[9],"of":[10,35,77],"the":[11,25],"total":[12],"energy":[13,33,42,55],"demand,":[14],"whereas":[15],"non-intrusive":[16,68],"load":[17,69],"disaggregation":[18,34,70],"has":[19],"been":[20],"dominated":[21],"by":[22],"applications":[23],"in":[24],"residential":[26],"domain.":[27],"Existing":[28],"on-site":[29,78],"sensor-based":[30],"approaches":[31],"for":[32,54,72],"SMBs":[36],"are":[37,52],"not":[38],"scalable":[39],"limit":[41],"efficiency":[43],"analysis,":[44],"usage":[45],"behavior":[46],"study,":[47],"kind-of-site":[49],"classification,":[50],"which":[51,74],"essential":[53],"management":[56],"grid":[58],"operations.":[59],"In":[60],"this":[61],"paper,":[62],"we":[63],"propose":[64],"highly":[66],"scalable,":[67],"model":[71],"SMBs,":[73],"is":[75],"independent":[76],"sensor":[79],"data.":[80]},"counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
