{"id":"https://openalex.org/W3030859819","doi":"https://doi.org/10.1145/3386415.3387007","title":"Optimized Power Equipment Maintenance Strategy Based on Risk Assessment","display_name":"Optimized Power Equipment Maintenance Strategy Based on Risk Assessment","publication_year":2019,"publication_date":"2019-12-06","ids":{"openalex":"https://openalex.org/W3030859819","doi":"https://doi.org/10.1145/3386415.3387007","mag":"3030859819"},"language":"en","primary_location":{"id":"doi:10.1145/3386415.3387007","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3386415.3387007","pdf_url":null,"source":{"id":"https://openalex.org/S4306523750","display_name":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100674292","display_name":"Xiaoxin Chen","orcid":"https://orcid.org/0000-0003-1845-5153"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Xiaoxin Chen","raw_affiliation_strings":["State Grid Zhejiang Electric Power Research Institute, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Research Institute, Hangzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007452898","display_name":"Ping Qian","orcid":"https://orcid.org/0000-0002-8803-8331"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ping Qian","raw_affiliation_strings":["State Grid Zhejiang Electric Power Co., Ltd. Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Co., Ltd. Hangzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100369763","display_name":"Chen Li","orcid":"https://orcid.org/0000-0001-6249-8957"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chen Li","raw_affiliation_strings":["State Grid Zhejiang Electric Power Research Institute, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Research Institute, Hangzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112374501","display_name":"HE Wen-lin","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wenlin He","raw_affiliation_strings":["State Grid Zhejiang Electric Power Research Institute, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Research Institute, Hangzhou, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100390318","display_name":"Wenhao Wang","orcid":"https://orcid.org/0000-0002-9369-9492"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wenhao Wang","raw_affiliation_strings":["State Grid Zhejiang Electric Power Research Institute, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Research Institute, Hangzhou, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103892941","display_name":"Xianjun Shao","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xianjun Shao","raw_affiliation_strings":["State Grid Zhejiang Electric Power Research Institute, Hangzhou, China"],"affiliations":[{"raw_affiliation_string":"State Grid Zhejiang Electric Power Research Institute, Hangzhou, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5100674292"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.48188804,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9904999732971191,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.9296000003814697,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.7430362105369568},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.6481838822364807},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"Predictive maintenance","score":0.5549792647361755},{"id":"https://openalex.org/keywords/preventive-maintenance","display_name":"Preventive maintenance","score":0.5291536450386047},{"id":"https://openalex.org/keywords/proactive-maintenance","display_name":"Proactive maintenance","score":0.522494375705719},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.5198586583137512},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"Condition-based maintenance","score":0.4972837269306183},{"id":"https://openalex.org/keywords/power-grid","display_name":"Power grid","score":0.4547807276248932},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45266541838645935},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3489748537540436},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.28734055161476135},{"id":"https://openalex.org/keywords/business","display_name":"Business","score":0.09691816568374634}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7430362105369568},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.6481838822364807},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.5549792647361755},{"id":"https://openalex.org/C24090081","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Preventive maintenance","level":2,"score":0.5291536450386047},{"id":"https://openalex.org/C141417316","wikidata":"https://www.wikidata.org/wiki/Q3278390","display_name":"Proactive maintenance","level":3,"score":0.522494375705719},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.5198586583137512},{"id":"https://openalex.org/C2776907094","wikidata":"https://www.wikidata.org/wiki/Q1043452","display_name":"Condition-based maintenance","level":2,"score":0.4972837269306183},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.4547807276248932},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45266541838645935},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3489748537540436},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28734055161476135},{"id":"https://openalex.org/C144133560","wikidata":"https://www.wikidata.org/wiki/Q4830453","display_name":"Business","level":0,"score":0.09691816568374634},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3386415.3387007","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3386415.3387007","pdf_url":null,"source":{"id":"https://openalex.org/S4306523750","display_name":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2nd International Conference on Information Technologies and Electrical Engineering","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":2,"referenced_works":["https://openalex.org/W2155837554","https://openalex.org/W2386159172"],"related_works":["https://openalex.org/W4311235937","https://openalex.org/W2195885512","https://openalex.org/W3145420912","https://openalex.org/W23403803","https://openalex.org/W2361723936","https://openalex.org/W3006925589","https://openalex.org/W2360058403","https://openalex.org/W2126792546","https://openalex.org/W2136937668","https://openalex.org/W4360585628"],"abstract_inverted_index":{"The":[0],"traditional":[1],"maintenance":[2,27,34,83],"method":[3,35,51],"for":[4,52,71,85],"power":[5,53,86],"equipment":[6,54,87,98],"is":[7,88],"likely":[8],"to":[9,36],"cause":[10],"over-maintenance":[11],"or":[12],"insufficient":[13],"maintenance,":[14],"resulting":[15],"in":[16],"huge":[17],"waste":[18],"of":[19,40,67,97],"human":[20],"and":[21,59,95],"material":[22],"resources.":[23],"Consequently,":[24],"risk":[25,49,72,78],"based":[26,55],"has":[28],"been":[29],"developed":[30],"as":[31],"a":[32,47],"new":[33],"meet":[37],"the":[38,41,65,76,93],"needs":[39],"smart":[42],"grid.":[43],"This":[44],"paper":[45],"proposes":[46],"novel":[48],"assessment":[50,79],"on":[56,75],"health":[57],"index":[58],"historical":[60],"failure":[61],"data,":[62],"which":[63,90],"overcomes":[64],"limitations":[66],"using":[68],"single":[69],"feature":[70],"assessment.":[73],"Based":[74],"proposed":[77],"method,":[80],"an":[81],"optimized":[82],"strategy":[84],"established,":[89],"greatly":[91],"improves":[92],"efficiency":[94],"effectiveness":[96],"maintenance.":[99]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}