{"id":"https://openalex.org/W3033170415","doi":"https://doi.org/10.1145/3384441.3395989","title":"Evaluation of Link Failure Resilience in Multirail Dragonfly-Class Networks through Simulation","display_name":"Evaluation of Link Failure Resilience in Multirail Dragonfly-Class Networks through Simulation","publication_year":2020,"publication_date":"2020-06-07","ids":{"openalex":"https://openalex.org/W3033170415","doi":"https://doi.org/10.1145/3384441.3395989","mag":"3033170415"},"language":"en","primary_location":{"id":"doi:10.1145/3384441.3395989","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3384441.3395989","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2020 ACM SIGSIM Conference on Principles of Advanced Discrete Simulation","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089195359","display_name":"Neil McGlohon","orcid":"https://orcid.org/0000-0001-8304-4911"},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Neil McGlohon","raw_affiliation_strings":["Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5036808423","display_name":"Robert Ross","orcid":"https://orcid.org/0000-0002-5435-5857"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Robert B. Ross","raw_affiliation_strings":["Argonne National Laboratory, Lemont, IL, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Argonne National Laboratory, Lemont, IL, USA","institution_ids":["https://openalex.org/I1282105669"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5061545857","display_name":"Christopher D. Carothers","orcid":null},"institutions":[{"id":"https://openalex.org/I165799507","display_name":"Rensselaer Polytechnic Institute","ror":"https://ror.org/01rtyzb94","country_code":"US","type":"education","lineage":["https://openalex.org/I165799507"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Christopher D. Carothers","raw_affiliation_strings":["Rensselaer Polytechnic Institute, Troy, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Rensselaer Polytechnic Institute, Troy, NY, USA","institution_ids":["https://openalex.org/I165799507"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5089195359"],"corresponding_institution_ids":["https://openalex.org/I165799507"],"apc_list":null,"apc_paid":null,"fwci":0.3237,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.61449766,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"105","last_page":"116"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10829","display_name":"Interconnection Networks and Systems","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10847","display_name":"Advanced Optical Network Technologies","score":0.9977999925613403,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11032","display_name":"VLSI and Analog Circuit Testing","score":0.996999979019165,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5238211750984192},{"id":"https://openalex.org/keywords/resilience","display_name":"Resilience (materials science)","score":0.514306902885437},{"id":"https://openalex.org/keywords/electromagnetic-interference","display_name":"Electromagnetic interference","score":0.5028337836265564},{"id":"https://openalex.org/keywords/interconnection","display_name":"Interconnection","score":0.4931277930736542},{"id":"https://openalex.org/keywords/bandwidth","display_name":"Bandwidth (computing)","score":0.4816095530986786},{"id":"https://openalex.org/keywords/router","display_name":"Router","score":0.46519386768341064},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.44186466932296753},{"id":"https://openalex.org/keywords/optical-performance-monitoring","display_name":"Optical performance monitoring","score":0.4196488857269287},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3888283371925354},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.387307345867157},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.33247804641723633},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.3183504343032837},{"id":"https://openalex.org/keywords/wavelength-division-multiplexing","display_name":"Wavelength-division multiplexing","score":0.27044355869293213},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.17542177438735962},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.13133808970451355}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5238211750984192},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.514306902885437},{"id":"https://openalex.org/C184892835","wikidata":"https://www.wikidata.org/wiki/Q1474513","display_name":"Electromagnetic interference","level":2,"score":0.5028337836265564},{"id":"https://openalex.org/C123745756","wikidata":"https://www.wikidata.org/wiki/Q1665949","display_name":"Interconnection","level":2,"score":0.4931277930736542},{"id":"https://openalex.org/C2776257435","wikidata":"https://www.wikidata.org/wiki/Q1576430","display_name":"Bandwidth (computing)","level":2,"score":0.4816095530986786},{"id":"https://openalex.org/C2775896111","wikidata":"https://www.wikidata.org/wiki/Q642560","display_name":"Router","level":2,"score":0.46519386768341064},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.44186466932296753},{"id":"https://openalex.org/C26840048","wikidata":"https://www.wikidata.org/wiki/Q7098880","display_name":"Optical performance monitoring","level":4,"score":0.4196488857269287},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3888283371925354},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.387307345867157},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33247804641723633},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3183504343032837},{"id":"https://openalex.org/C160724564","wikidata":"https://www.wikidata.org/wiki/Q1620670","display_name":"Wavelength-division multiplexing","level":3,"score":0.27044355869293213},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.17542177438735962},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.13133808970451355},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3384441.3395989","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3384441.3395989","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2020 ACM SIGSIM Conference on Principles of Advanced Discrete Simulation","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.4699999988079071,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G7954425250","display_name":null,"funder_award_id":"DE-AC02-06CH11357","funder_id":"https://openalex.org/F4320306084","funder_display_name":"U.S. Department of Energy"}],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1501077214","https://openalex.org/W1976533090","https://openalex.org/W2013769473","https://openalex.org/W2025879446","https://openalex.org/W2057218453","https://openalex.org/W2086263221","https://openalex.org/W2088219312","https://openalex.org/W2108255464","https://openalex.org/W2108465315","https://openalex.org/W2108990513","https://openalex.org/W2143404251","https://openalex.org/W2156864916","https://openalex.org/W2158800303","https://openalex.org/W2293536430","https://openalex.org/W2296636214","https://openalex.org/W2332895340","https://openalex.org/W2363845455","https://openalex.org/W2588397760","https://openalex.org/W2599132532","https://openalex.org/W2607241962","https://openalex.org/W2731948420","https://openalex.org/W2734733109","https://openalex.org/W2749563674","https://openalex.org/W2752885492","https://openalex.org/W2767749225","https://openalex.org/W2803466590","https://openalex.org/W2946046356","https://openalex.org/W2947289895","https://openalex.org/W2947543664","https://openalex.org/W2947900277","https://openalex.org/W2948357195","https://openalex.org/W2964456616"],"related_works":["https://openalex.org/W2122026593","https://openalex.org/W1588358165","https://openalex.org/W4237683758","https://openalex.org/W2582203024","https://openalex.org/W2370711413","https://openalex.org/W2375932043","https://openalex.org/W2052038519","https://openalex.org/W2841075164","https://openalex.org/W1980506749","https://openalex.org/W2155019192"],"abstract_inverted_index":{"During":[0],"long-term":[1],"operation":[2],"of":[3,11,61,70,82,88],"a":[4,44,77],"high-performance":[5],"computing":[6],"(HPC)":[7],"system":[8],"with":[9,76,86],"thousands":[10],"components,":[12],"many":[13],"components":[14],"will":[15],"inevitably":[16],"fail.":[17],"The":[18,68],"current":[19],"trend":[20],"in":[21,43],"HPC":[22],"interconnect":[23],"router":[24],"linkage":[25],"is":[26],"moving":[27],"away":[28],"from":[29,64],"passive":[30,89],"copper":[31,90],"and":[32,51,57],"toward":[33],"active":[34,71],"optical-based":[35],"cables.":[36,67,91],"Optical":[37],"links":[38],"offer":[39],"greater":[40],"bandwidth":[41],"maximums":[42],"smaller":[45],"wire":[46],"gauge,":[47],"less":[48],"signal":[49],"loss,":[50],"lower":[52],"latency":[53],"over":[54],"long":[55],"distances":[56],"have":[58],"no":[59],"risk":[60,81],"electromagnetic":[62],"interference":[63],"other":[65],"nearby":[66],"benefits":[69],"optical":[72],"links,":[73],"however,":[74],"come":[75],"cost:":[78],"an":[79],"increased":[80],"component":[83],"failure":[84],"compared":[85],"that":[87]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":1}],"updated_date":"2026-04-26T08:31:28.666265","created_date":"2025-10-10T00:00:00"}
