{"id":"https://openalex.org/W2955484208","doi":"https://doi.org/10.1145/3326172.3326205","title":"Spectroscopic Properties of Blood for Pulse Oximeter Design","display_name":"Spectroscopic Properties of Blood for Pulse Oximeter Design","publication_year":2019,"publication_date":"2019-03-28","ids":{"openalex":"https://openalex.org/W2955484208","doi":"https://doi.org/10.1145/3326172.3326205","mag":"2955484208"},"language":"en","primary_location":{"id":"doi:10.1145/3326172.3326205","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3326172.3326205","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5046088691","display_name":"Abeera Vaqar","orcid":null},"institutions":[{"id":"https://openalex.org/I929597975","display_name":"National University of Sciences and Technology","ror":"https://ror.org/03w2j5y17","country_code":"PK","type":"education","lineage":["https://openalex.org/I929597975"]}],"countries":["PK"],"is_corresponding":true,"raw_author_name":"Abeera Vaqar","raw_affiliation_strings":["National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, College of Electrical and Mechanical Engineering (CEME)"],"affiliations":[{"raw_affiliation_string":"National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, College of Electrical and Mechanical Engineering (CEME)","institution_ids":["https://openalex.org/I929597975"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059397862","display_name":"Intisar Rizwan I Haque","orcid":"https://orcid.org/0000-0003-3702-8923"},"institutions":[{"id":"https://openalex.org/I929597975","display_name":"National University of Sciences and Technology","ror":"https://ror.org/03w2j5y17","country_code":"PK","type":"education","lineage":["https://openalex.org/I929597975"]}],"countries":["PK"],"is_corresponding":false,"raw_author_name":"Intisar Rizwan I. Haque","raw_affiliation_strings":["National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, Military College of Signals (MCS)"],"affiliations":[{"raw_affiliation_string":"National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, Military College of Signals (MCS)","institution_ids":["https://openalex.org/I929597975"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5084385413","display_name":"Tahir Zaidi","orcid":null},"institutions":[{"id":"https://openalex.org/I929597975","display_name":"National University of Sciences and Technology","ror":"https://ror.org/03w2j5y17","country_code":"PK","type":"education","lineage":["https://openalex.org/I929597975"]}],"countries":["PK"],"is_corresponding":false,"raw_author_name":"Tahir Zaidi","raw_affiliation_strings":["National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, College of Electrical and Mechanical Engineering (CEME)"],"affiliations":[{"raw_affiliation_string":"National University of Sciences and Technology, Pakistan, Department of Electrical Engineering, College of Electrical and Mechanical Engineering (CEME)","institution_ids":["https://openalex.org/I929597975"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5046088691"],"corresponding_institution_ids":["https://openalex.org/I929597975"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.06294775,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"217","last_page":"222"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10977","display_name":"Optical Imaging and Spectroscopy Techniques","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.6994585394859314},{"id":"https://openalex.org/keywords/pulse","display_name":"Pulse (music)","score":0.6001498699188232},{"id":"https://openalex.org/keywords/wavelength","display_name":"Wavelength","score":0.5857369899749756},{"id":"https://openalex.org/keywords/oxygen-saturation","display_name":"Oxygen saturation","score":0.5372531414031982},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.5335676670074463},{"id":"https://openalex.org/keywords/transmittance","display_name":"Transmittance","score":0.5223535299301147},{"id":"https://openalex.org/keywords/pulse-oximetry","display_name":"Pulse oximetry","score":0.5002593994140625},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.49683573842048645},{"id":"https://openalex.org/keywords/arterial-blood","display_name":"Arterial blood","score":0.4615485966205597},{"id":"https://openalex.org/keywords/near-infrared-spectroscopy","display_name":"Near-infrared spectroscopy","score":0.41949212551116943},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.4168448746204376},{"id":"https://openalex.org/keywords/absorbance","display_name":"Absorbance","score":0.4167477488517761},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.33121731877326965},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.3272736668586731},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.3123939633369446},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.2781091332435608},{"id":"https://openalex.org/keywords/oxygen","display_name":"Oxygen","score":0.19974195957183838},{"id":"https://openalex.org/keywords/anesthesia","display_name":"Anesthesia","score":0.18474292755126953},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.16728666424751282},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.15837505459785461},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.1307666003704071},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.09202784299850464}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.6994585394859314},{"id":"https://openalex.org/C2780167933","wikidata":"https://www.wikidata.org/wiki/Q1550652","display_name":"Pulse (music)","level":3,"score":0.6001498699188232},{"id":"https://openalex.org/C6260449","wikidata":"https://www.wikidata.org/wiki/Q41364","display_name":"Wavelength","level":2,"score":0.5857369899749756},{"id":"https://openalex.org/C76538665","wikidata":"https://www.wikidata.org/wiki/Q6294669","display_name":"Oxygen saturation","level":3,"score":0.5372531414031982},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.5335676670074463},{"id":"https://openalex.org/C150493377","wikidata":"https://www.wikidata.org/wiki/Q1427863","display_name":"Transmittance","level":2,"score":0.5223535299301147},{"id":"https://openalex.org/C2780124106","wikidata":"https://www.wikidata.org/wiki/Q1140495","display_name":"Pulse oximetry","level":2,"score":0.5002593994140625},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.49683573842048645},{"id":"https://openalex.org/C2779537118","wikidata":"https://www.wikidata.org/wiki/Q618362","display_name":"Arterial blood","level":2,"score":0.4615485966205597},{"id":"https://openalex.org/C43571822","wikidata":"https://www.wikidata.org/wiki/Q599037","display_name":"Near-infrared spectroscopy","level":2,"score":0.41949212551116943},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4168448746204376},{"id":"https://openalex.org/C98015330","wikidata":"https://www.wikidata.org/wiki/Q907315","display_name":"Absorbance","level":2,"score":0.4167477488517761},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.33121731877326965},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3272736668586731},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3123939633369446},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.2781091332435608},{"id":"https://openalex.org/C540031477","wikidata":"https://www.wikidata.org/wiki/Q629","display_name":"Oxygen","level":2,"score":0.19974195957183838},{"id":"https://openalex.org/C42219234","wikidata":"https://www.wikidata.org/wiki/Q131130","display_name":"Anesthesia","level":1,"score":0.18474292755126953},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.16728666424751282},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.15837505459785461},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1307666003704071},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.09202784299850464},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3326172.3326205","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3326172.3326205","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2019 9th International Conference on Biomedical Engineering and Technology","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.5299999713897705,"display_name":"Good health and well-being"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W106504929","https://openalex.org/W132284657","https://openalex.org/W134106406","https://openalex.org/W1905603695","https://openalex.org/W1972116768","https://openalex.org/W1992783375","https://openalex.org/W2004290081","https://openalex.org/W2007708683","https://openalex.org/W2010755629","https://openalex.org/W2022778022","https://openalex.org/W2040152030","https://openalex.org/W2066379758","https://openalex.org/W2067957471","https://openalex.org/W2071229756","https://openalex.org/W2076597049","https://openalex.org/W2083783275","https://openalex.org/W2085765714","https://openalex.org/W2087851757","https://openalex.org/W2089724274","https://openalex.org/W2093024335","https://openalex.org/W2136092278","https://openalex.org/W2144475623","https://openalex.org/W2147860222","https://openalex.org/W2148293218","https://openalex.org/W2148744889","https://openalex.org/W2520917352","https://openalex.org/W2552423530","https://openalex.org/W2559110501","https://openalex.org/W2755519984","https://openalex.org/W2791965194","https://openalex.org/W4210939028","https://openalex.org/W4285719527"],"related_works":["https://openalex.org/W2938254392","https://openalex.org/W2032224110","https://openalex.org/W2917448342","https://openalex.org/W2884526288","https://openalex.org/W2365654996","https://openalex.org/W2091413177","https://openalex.org/W2884774174","https://openalex.org/W24219778","https://openalex.org/W2068141149","https://openalex.org/W2021651157"],"abstract_inverted_index":{"Pulse":[0,68],"oximeter":[1,39,69],"is":[2,9,105,140,166,180,198,201],"an":[3],"important":[4],"medical":[5],"device":[6,40],"as":[7],"it":[8],"used":[10,275],"for":[11,16,41,236,276],"emergency":[12],"situations":[13],"in":[14,171,222,286],"hospitals":[15],"monitoring":[17],"patient's":[18],"peripheral":[19],"oxygen":[20,205],"saturation":[21],"(%SpO2).":[22],"For":[23,243],"more":[24,267],"than":[25,268],"30":[26],"years":[27],"many":[28],"research":[29],"studies":[30],"have":[31],"focused":[32],"on":[33,86,131,281],"designing":[34,237,277],"a":[35,144,160,246],"wearable":[36],"compact":[37],"pulse":[38,78,93,241,278],"accurate":[42],"%SpO2":[43,60,71],"measurements.":[44],"Most":[45],"of":[46,73,83,97,153,159,190,215,226,248,251,262,271],"these":[47],"devices":[48],"provide":[49],"values":[50,284],"that":[51,266],"are":[52],"either":[53],"2%":[54],"above":[55],"or":[56],"below":[57],"the":[58,77,84,87,90,95,113,117,132,138,147,151,169,176,212,223,232,238,282,287],"desired":[59],"values,":[61],"calculated":[62,199],"using":[63],"arterial":[64,74,172,204],"blood":[65,75,173,216],"gas":[66],"(ABG).":[67],"provides":[70],"readings":[72,219],"and":[76,102,116,150,175,185,195,200,230,253,289],"rate":[79],"through":[80,217],"convenient":[81],"placement":[82],"sensor":[85],"finger.":[88],"In":[89,207],"transmittance":[91,239],"type":[92,240],"oximeter,":[94],"absorbance":[96,283],"light":[98,139,148],"by":[99],"oxy":[100],"hemoglobin":[101,104],"de-oxy":[103],"measured":[106],"at":[107],"two":[108,122],"wavelengths":[109,256,272],"one":[110,269],"each":[111,136],"from":[112,127,220],"Red":[114,194,252,290],"band":[115,255],"Infrared":[118],"(IR)":[119],"band.":[120],"The":[121,155,188,260],"band's":[123],"combined":[124],"wavelength":[125,224,234],"ranges":[126],"600nm":[128,227],"to":[129,168,182,193,203,228],"1000nm":[130,229],"electromagnetic":[133],"spectrum.":[134],"At":[135],"wavelength,":[137],"detected":[141,156],"after":[142],"placing":[143],"finger":[145,221],"between":[146],"source":[149],"detector":[152],"spectrophotometer.":[154],"signal":[157,164],"consists":[158],"cardiac":[161],"synchronous":[162],"AC":[163],"which":[165,179],"due":[167,181],"changes":[170],"volume,":[174],"DC":[177],"level":[178],"bone,":[183],"tissue":[184],"non-pulsatile":[186],"blood.":[187],"ratio":[189],"signals":[191],"corresponding":[192],"IR":[196,254,288],"bands":[197,291],"related":[202],"saturation.":[206],"this":[208,244],"paper,":[209],"we":[210],"investigate":[211],"spectral":[213],"properties":[214],"spectrophotometer-based":[218],"range":[225],"determine":[231],"optimum":[233],"combination":[235,270],"oximeter.":[242],"purpose,":[245],"comparison":[247],"all":[249],"combinations":[250],"was":[257],"carried":[258],"out.":[259],"results":[261],"our":[263],"study":[264],"indicate":[265],"can":[273],"be":[274],"oximeters":[279],"based":[280],"observed":[285]},"counts_by_year":[{"year":2023,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
