{"id":"https://openalex.org/W2905688272","doi":"https://doi.org/10.1145/3277453.3277455","title":"Research on Fault Detection and Protection Strategy of HVDC Circuit Breaker Based on New Criterion","display_name":"Research on Fault Detection and Protection Strategy of HVDC Circuit Breaker Based on New Criterion","publication_year":2018,"publication_date":"2018-09-19","ids":{"openalex":"https://openalex.org/W2905688272","doi":"https://doi.org/10.1145/3277453.3277455","mag":"2905688272"},"language":"en","primary_location":{"id":"doi:10.1145/3277453.3277455","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3277453.3277455","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100716772","display_name":"Wei Li","orcid":"https://orcid.org/0000-0003-1158-5414"},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Wei Li","raw_affiliation_strings":["Electrical Engineering, North China Electric Power University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108202533","display_name":"Xueguang Wu","orcid":null},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xueguang Wu","raw_affiliation_strings":["Electrical Engineering, North China Electric Power University, Beijing, China"],"affiliations":[{"raw_affiliation_string":"Electrical Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101556329","display_name":"Bin Chang","orcid":"https://orcid.org/0000-0001-7858-3996"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Bin Chang","raw_affiliation_strings":["Global Energy Interconnection, Research Institute Co. Ltd"],"affiliations":[{"raw_affiliation_string":"Global Energy Interconnection, Research Institute Co. Ltd","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5070799528","display_name":"Dong Liu","orcid":"https://orcid.org/0000-0003-3139-2708"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dong Liu","raw_affiliation_strings":["Beijing Key Laboratory of DC Grid, Technology and Simulation, Global Energy Interconnection, Research Institute Co. Ltd"],"affiliations":[{"raw_affiliation_string":"Beijing Key Laboratory of DC Grid, Technology and Simulation, Global Energy Interconnection, Research Institute Co. Ltd","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5100716772"],"corresponding_institution_ids":["https://openalex.org/I153473198"],"apc_list":null,"apc_paid":null,"fwci":0.1839,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.53068512,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":93},"biblio":{"volume":null,"issue":null,"first_page":"7","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9896000027656555,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.915376603603363},{"id":"https://openalex.org/keywords/busbar","display_name":"Busbar","score":0.7926086187362671},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.7035303711891174},{"id":"https://openalex.org/keywords/transient-recovery-voltage","display_name":"Transient recovery voltage","score":0.5882387757301331},{"id":"https://openalex.org/keywords/line","display_name":"Line (geometry)","score":0.4789860248565674},{"id":"https://openalex.org/keywords/transient","display_name":"Transient (computer programming)","score":0.46575242280960083},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4615744352340698},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.4576283097267151},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4428398013114929},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.43559786677360535},{"id":"https://openalex.org/keywords/arc-fault-circuit-interrupter","display_name":"Arc-fault circuit interrupter","score":0.4333977699279785},{"id":"https://openalex.org/keywords/electric-power-transmission","display_name":"Electric power transmission","score":0.43322402238845825},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4309902787208557},{"id":"https://openalex.org/keywords/transmission-line","display_name":"Transmission line","score":0.41880208253860474},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4131316840648651},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3608873188495636},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35380181670188904},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3361814618110657},{"id":"https://openalex.org/keywords/short-circuit","display_name":"Short circuit","score":0.23233529925346375},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.18882521986961365}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.915376603603363},{"id":"https://openalex.org/C192690417","wikidata":"https://www.wikidata.org/wiki/Q1030817","display_name":"Busbar","level":2,"score":0.7926086187362671},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7035303711891174},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.5882387757301331},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4789860248565674},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.46575242280960083},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4615744352340698},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4576283097267151},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4428398013114929},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.43559786677360535},{"id":"https://openalex.org/C157069517","wikidata":"https://www.wikidata.org/wiki/Q132172","display_name":"Arc-fault circuit interrupter","level":4,"score":0.4333977699279785},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.43322402238845825},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4309902787208557},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.41880208253860474},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4131316840648651},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3608873188495636},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35380181670188904},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3361814618110657},{"id":"https://openalex.org/C68583231","wikidata":"https://www.wikidata.org/wiki/Q206907","display_name":"Short circuit","level":3,"score":0.23233529925346375},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.18882521986961365},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3277453.3277455","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3277453.3277455","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2018 International Conference on Electronics and Electrical Engineering Technology","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W1607168430","https://openalex.org/W2124168238","https://openalex.org/W2353624040","https://openalex.org/W2360348645","https://openalex.org/W2385098485","https://openalex.org/W2496306568"],"related_works":["https://openalex.org/W3029101738","https://openalex.org/W2169529353","https://openalex.org/W2266900650","https://openalex.org/W4243604858","https://openalex.org/W2164183860","https://openalex.org/W2034343262","https://openalex.org/W2914054235","https://openalex.org/W2097619530","https://openalex.org/W2074469235","https://openalex.org/W3112906567"],"abstract_inverted_index":{"Increasing":[0],"the":[1,5,10,24,59,65,76,89,96,100,113,116,120,146],"breaking":[2],"speed":[3,90,124],"of":[4,23,67,69,75,91,98,102,115,125,160],"HVDC":[6,45,52,139],"circuit":[7,162],"breaker":[8],"in":[9],"DC":[11,77,161],"grid":[12],"can":[13,82],"provide":[14],"an":[15],"additional":[16],"necessary":[17],"time":[18],"for":[19,44,155],"other":[20],"control":[21,42,158],"strategies":[22],"VSC-HVDC":[25],"system":[26,140],"during":[27],"fault":[28,35,84],"conditions.":[29,135],"This":[30,55],"paper":[31],"presents":[32],"a":[33,137,151],"new":[34,152],"local":[36,85,107],"detection":[37],"and":[38,87,106,112,119,123],"power":[39],"line":[40,60],"protection":[41,92,126],"strategy":[43,159],"breakers":[46],"based":[47],"on":[48],"Zhangbei":[49],"four-terminal":[50],"flexible":[51,138],"transmission":[53],"project.":[54],"method":[56,81,97,118,149],"determines":[57],"if":[58],"has":[61],"faults":[62,101],"by":[63,130],"monitoring":[64],"rate":[66],"change":[68],"voltage":[70],"(ROCOV)":[71],"at":[72],"both":[73],"ends":[74],"line.":[78],"And":[79],"this":[80,148],"realize":[83],"judgment":[86],"improve":[88],"operation.":[93],"In":[94],"addition,":[95],"distinguishing":[99],"adjacent":[103],"lines,":[104],"busbars":[105],"lines":[108],"is":[109],"specifically":[110],"proposed,":[111],"accuracy":[114],"proposed":[117],"selectivity,":[121],"reliability":[122],"actions":[127],"are":[128],"verified":[129],"PSCAD":[131],"under":[132],"different":[133],"working":[134],"For":[136],"which":[141],"needs":[142],"to":[143],"quickly":[144],"clear":[145],"fault,":[147],"provides":[150],"research":[153],"idea":[154],"rapid":[156],"self-breaking":[157],"breaker.":[163]},"counts_by_year":[{"year":2021,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
