{"id":"https://openalex.org/W2764056296","doi":"https://doi.org/10.1145/3132479.3132482","title":"A novel fault diagnostic technique for photovoltaic systems based on cascaded forest","display_name":"A novel fault diagnostic technique for photovoltaic systems based on cascaded forest","publication_year":2017,"publication_date":"2017-10-03","ids":{"openalex":"https://openalex.org/W2764056296","doi":"https://doi.org/10.1145/3132479.3132482","mag":"2764056296"},"language":"en","primary_location":{"id":"doi:10.1145/3132479.3132482","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3132479.3132482","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Workshop on Smart Internet of Things","raw_type":"proceedings-article"},"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5077711926","display_name":"Liangqing Hu","orcid":"https://orcid.org/0000-0002-6178-2021"},"institutions":[{"id":"https://openalex.org/I150807315","display_name":"Guangxi University","ror":"https://ror.org/02c9qn167","country_code":"CN","type":"education","lineage":["https://openalex.org/I150807315"]},{"id":"https://openalex.org/I4387153915","display_name":"Guilin University","ror":"https://ror.org/00jbpxw47","country_code":null,"type":"education","lineage":["https://openalex.org/I4387153915"]},{"id":"https://openalex.org/I5343935","display_name":"Guilin University of Electronic Technology","ror":"https://ror.org/05arjae42","country_code":"CN","type":"education","lineage":["https://openalex.org/I5343935"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liangqing Hu","raw_affiliation_strings":["Guangxi University, Nanning, China and Guilin University of Electronic Technology and Guangxi Colleges and Universities Key Laboratory of cloud computing and complex systems and Guilin University of Electronic Technology, Guilin, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Guangxi University, Nanning, China and Guilin University of Electronic Technology and Guangxi Colleges and Universities Key Laboratory of cloud computing and complex systems and Guilin University of Electronic Technology, Guilin, China","institution_ids":["https://openalex.org/I150807315","https://openalex.org/I4387153915","https://openalex.org/I5343935"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101492539","display_name":"Ye Jin","orcid":"https://orcid.org/0000-0001-8087-6333"},"institutions":[{"id":"https://openalex.org/I150807315","display_name":"Guangxi University","ror":"https://ror.org/02c9qn167","country_code":"CN","type":"education","lineage":["https://openalex.org/I150807315"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jin Ye","raw_affiliation_strings":["Guangxi University, Nanning, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Guangxi University, Nanning, China","institution_ids":["https://openalex.org/I150807315"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067885959","display_name":"Shengqiang Chang","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Shengqiang Chang","raw_affiliation_strings":["Shijiazhuang Kelin Electric Co., Ltd., Shijiazhuang, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shijiazhuang Kelin Electric Co., Ltd., Shijiazhuang, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031566939","display_name":"Hongtao Li","orcid":"https://orcid.org/0000-0002-2681-4083"},"institutions":[{"id":"https://openalex.org/I150807315","display_name":"Guangxi University","ror":"https://ror.org/02c9qn167","country_code":"CN","type":"education","lineage":["https://openalex.org/I150807315"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongtao Li","raw_affiliation_strings":["Guangxi University, Nanning, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Guangxi University, Nanning, China","institution_ids":["https://openalex.org/I150807315"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5115601812","display_name":"Hongyu Chen","orcid":"https://orcid.org/0000-0002-5325-9249"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hongyu Chen","raw_affiliation_strings":["Shijiazhuang Kelin Electric Co., Ltd., Shijiazhuang, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shijiazhuang Kelin Electric Co., Ltd., Shijiazhuang, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.9865999817848206,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11276","display_name":"Solar Radiation and Photovoltaics","score":0.9660999774932861,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photovoltaic-system","display_name":"Photovoltaic system","score":0.8663207292556763},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6684821844100952},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.513472855091095},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.49846887588500977},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4842659831047058},{"id":"https://openalex.org/keywords/fault-coverage","display_name":"Fault coverage","score":0.41813600063323975},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.39611196517944336},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3510957360267639},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.34965136647224426},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.29069608449935913},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.18435397744178772},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.14362770318984985},{"id":"https://openalex.org/keywords/electronic-circuit","display_name":"Electronic circuit","score":0.09886914491653442}],"concepts":[{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.8663207292556763},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6684821844100952},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.513472855091095},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.49846887588500977},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4842659831047058},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.41813600063323975},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.39611196517944336},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3510957360267639},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.34965136647224426},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29069608449935913},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18435397744178772},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.14362770318984985},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.09886914491653442},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3132479.3132482","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3132479.3132482","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the Workshop on Smart Internet of Things","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W1993944577","https://openalex.org/W2151211112","https://openalex.org/W2280977705","https://openalex.org/W2592340788","https://openalex.org/W4256060553"],"related_works":["https://openalex.org/W2575775159","https://openalex.org/W2517701025","https://openalex.org/W2026330267","https://openalex.org/W4311537696","https://openalex.org/W2050630979","https://openalex.org/W2386166483","https://openalex.org/W2620568181","https://openalex.org/W2387459476","https://openalex.org/W3015409655","https://openalex.org/W2383699822"],"abstract_inverted_index":{"A":[0],"variety":[1],"of":[2,9,19,25,28,37,60,63,70,78,103,139,164],"faults":[3],"often":[4],"occur":[5],"during":[6],"the":[7,16,20,22,26,35,57,61,75,79,91,94,107,116,121,126,131,160],"operation":[8,18],"PV":[10,64,92,127,142],"arrays,":[11],"which":[12],"may":[13],"seriously":[14],"affect":[15],"normal":[17],"system,":[21],"machine":[23],"diagnosis":[24,80,88,123,163],"types":[27,138],"fault":[29,46,87,122,140,162],"has":[30,155],"become":[31],"a":[32,44,67,100,156],"hotspot":[33],"in":[34],"field":[36],"photovoltaic":[38,50],"power":[39],"generation.":[40],"This":[41,153],"paper":[42],"proposes":[43],"novel":[45],"diagnostic":[47],"technique":[48],"for":[49,90,125,141,159],"systems":[51],"based":[52,129],"on":[53,130],"Cascaded":[54],"Forest.":[55],"Through":[56],"in-depth":[58],"analysis":[59],"output":[62],"arrays":[65],"from":[66],"data":[68,105],"platform":[69],"Shijiazhuang":[71],"Kelin":[72],"Electric":[73],"Co,":[74],"input":[76],"variables":[77],"model":[81],"are":[82],"obtained.":[83],"Compared":[84],"with":[85],"other":[86],"methods":[89],"array,":[93],"proposed":[95],"method":[96,124,154],"can":[97,109,134],"work":[98],"under":[99],"small":[101],"number":[102],"tagged":[104],"and":[106,113,150],"system":[108],"be":[110],"run":[111],"online":[112],"real-time.":[114],"Finally,":[115],"experimental":[117],"results":[118],"show":[119],"that":[120],"array":[128,143],"cascading":[132],"forests":[133],"effectively":[135],"detect":[136],"four":[137],"such":[144],"as":[145],"short-circuit,":[146],"open-circuit,":[147],"abnormal":[148],"degradation":[149],"partial":[151],"shading.":[152],"good":[157],"value":[158],"intelligent":[161],"PV.":[165]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2020,"cited_by_count":2}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
