{"id":"https://openalex.org/W2755615816","doi":"https://doi.org/10.1145/3128128.3128129","title":"Smart campus energy management system","display_name":"Smart campus energy management system","publication_year":2017,"publication_date":"2017-07-21","ids":{"openalex":"https://openalex.org/W2755615816","doi":"https://doi.org/10.1145/3128128.3128129","mag":"2755615816"},"language":"en","primary_location":{"id":"doi:10.1145/3128128.3128129","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3128128.3128129","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2017 International Conference on Smart Digital Environment","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5016516110","display_name":"Hanaa Talei","orcid":"https://orcid.org/0000-0001-9603-0527"},"institutions":[{"id":"https://openalex.org/I47844","display_name":"Al Akhawayn University","ror":"https://ror.org/03erkev52","country_code":"MA","type":"education","lineage":["https://openalex.org/I47844"]}],"countries":["MA"],"is_corresponding":false,"raw_author_name":"Hanaa Talei","raw_affiliation_strings":["AlAkhawayn University in Ifrane, Ifrane, Morocco"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"AlAkhawayn University in Ifrane, Ifrane, Morocco","institution_ids":["https://openalex.org/I47844"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5056342867","display_name":"Mohamed Essaaidi","orcid":"https://orcid.org/0000-0001-9215-3263"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mohamed Essaaidi","raw_affiliation_strings":["ENSIAS School, Rabat, Morocco"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ENSIAS School, Rabat, Morocco","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5107999233","display_name":"Driss Benhaddou","orcid":null},"institutions":[{"id":"https://openalex.org/I44461941","display_name":"University of Houston","ror":"https://ror.org/048sx0r50","country_code":"US","type":"education","lineage":["https://openalex.org/I44461941"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Driss Benhaddou","raw_affiliation_strings":["University of Houston"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Houston","institution_ids":["https://openalex.org/I44461941"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.5848,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.70447924,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"7"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.9778646230697632},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.7049233913421631},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.6924746632575989},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.6917533874511719},{"id":"https://openalex.org/keywords/cloud-computing","display_name":"Cloud computing","score":0.6890332698822021},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6419172883033752},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.6345123052597046},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5163775682449341},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.4700915813446045},{"id":"https://openalex.org/keywords/architecture","display_name":"Architecture","score":0.44165536761283875},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.43836674094200134},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.3757266104221344},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.3562880754470825},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.3405299782752991},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2270416021347046},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.18887200951576233},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.1331104040145874}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.9778646230697632},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.7049233913421631},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.6924746632575989},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.6917533874511719},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.6890332698822021},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6419172883033752},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.6345123052597046},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5163775682449341},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.4700915813446045},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.44165536761283875},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.43836674094200134},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.3757266104221344},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.3562880754470825},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3405299782752991},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2270416021347046},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.18887200951576233},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.1331104040145874},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C142362112","wikidata":"https://www.wikidata.org/wiki/Q735","display_name":"Art","level":0,"score":0.0},{"id":"https://openalex.org/C153349607","wikidata":"https://www.wikidata.org/wiki/Q36649","display_name":"Visual arts","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/3128128.3128129","is_oa":false,"landing_page_url":"https://doi.org/10.1145/3128128.3128129","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 2017 International Conference on Smart Digital Environment","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W1591387237","https://openalex.org/W1604806267","https://openalex.org/W1934782761","https://openalex.org/W1965988806","https://openalex.org/W1972434047","https://openalex.org/W1986141527","https://openalex.org/W2008668719","https://openalex.org/W2022175690","https://openalex.org/W2068705049","https://openalex.org/W2081860558","https://openalex.org/W2086525536","https://openalex.org/W2120540932","https://openalex.org/W2135846084","https://openalex.org/W2142933425","https://openalex.org/W2157515174","https://openalex.org/W2159588611","https://openalex.org/W2296221482","https://openalex.org/W2305446084","https://openalex.org/W2342585240","https://openalex.org/W2537553621","https://openalex.org/W3144245279"],"related_works":["https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2906602677","https://openalex.org/W2051053503","https://openalex.org/W195896717","https://openalex.org/W2333017163","https://openalex.org/W2347673489","https://openalex.org/W2371966636","https://openalex.org/W4312501103","https://openalex.org/W3037868018"],"abstract_inverted_index":{"A":[0],"Microgrid":[1,43,59,90],"is":[2,56],"a":[3,8,22,25],"subset":[4],"of":[5,53,77,103],"smart":[6],"grid,":[7],"small-scale":[9],"electrical":[10],"system":[11],"powered":[12],"with":[13,61,100],"renewable":[14],"energy":[15,49,65],"resources":[16],"that":[17,33],"can":[18,85],"operate":[19],"either":[20],"in":[21],"connected":[23],"or":[24],"disconnected":[26],"mode":[27],"to/from":[28],"the":[29,72,89,94],"main":[30],"grid.":[31],"Given":[32,68],"universities":[34],"are":[35],"very":[36],"important":[37],"electricity":[38],"consumers,":[39],"using":[40,107],"an":[41,62,78],"academic":[42],"will":[44],"solve":[45],"many":[46],"problems":[47],"regarding":[48],"usage[1].":[50],"The":[51,97],"purpose":[52],"this":[54],"paper,":[55],"to":[57,88,92],"describe":[58],"components":[60],"emphasis":[63],"on":[64],"management":[66],"(EMS).":[67],"its":[69],"vital":[70],"role,":[71],"paper":[73,98],"presents":[74],"different":[75],"architectures":[76],"EMS":[79,95,104],"and":[80],"discusses":[81],"how":[82],"cloud":[83],"computing":[84],"be":[86],"incorporated":[87],"architecture":[91],"improve":[93],"efficiency.":[96],"concludes":[99],"presenting":[101],"results":[102],"data":[105],"collection":[106],"Kaa":[108],"IoT":[109],"platform.":[110]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
