{"id":"https://openalex.org/W2194508968","doi":"https://doi.org/10.1145/2834800.2834803","title":"Experimental design and comparative testing of a hybrid-cooled computer cluster","display_name":"Experimental design and comparative testing of a hybrid-cooled computer cluster","publication_year":2015,"publication_date":"2015-11-11","ids":{"openalex":"https://openalex.org/W2194508968","doi":"https://doi.org/10.1145/2834800.2834803","mag":"2194508968"},"language":"en","primary_location":{"id":"doi:10.1145/2834800.2834803","is_oa":true,"landing_page_url":"https://doi.org/10.1145/2834800.2834803","pdf_url":"http://dl.acm.org/ft_gateway.cfm?id=2834803&type=pdf","source":null,"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Workshop on Energy Efficient Supercomputing","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"http://dl.acm.org/ft_gateway.cfm?id=2834803&type=pdf","any_repository_has_fulltext":null},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056738620","display_name":"Amanda Bonnie","orcid":"https://orcid.org/0000-0003-0647-9916"},"institutions":[{"id":"https://openalex.org/I1343871089","display_name":"Los Alamos National Laboratory","ror":"https://ror.org/01e41cf67","country_code":"US","type":"facility","lineage":["https://openalex.org/I1330989302","https://openalex.org/I1343871089","https://openalex.org/I198811213","https://openalex.org/I4210120050"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Amanda Bonnie","raw_affiliation_strings":["Los Alamos National Lab, Los Alamos, New Mexico"],"affiliations":[{"raw_affiliation_string":"Los Alamos National Lab, Los Alamos, New Mexico","institution_ids":["https://openalex.org/I1343871089"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5056738620"],"corresponding_institution_ids":["https://openalex.org/I1343871089"],"apc_list":null,"apc_paid":null,"fwci":0.3169,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.6426548,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.9966999888420105,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10054","display_name":"Parallel Computing and Optimization Techniques","score":0.9940999746322632,"subfield":{"id":"https://openalex.org/subfields/1708","display_name":"Hardware and Architecture"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11181","display_name":"Advanced Data Storage Technologies","score":0.9919999837875366,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/chiller","display_name":"Chiller","score":0.8658488988876343},{"id":"https://openalex.org/keywords/data-center","display_name":"Data center","score":0.6904810070991516},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.5526325702667236},{"id":"https://openalex.org/keywords/water-cooling","display_name":"Water cooling","score":0.5227743983268738},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5035714507102966},{"id":"https://openalex.org/keywords/water-chiller","display_name":"Water chiller","score":0.49377068877220154},{"id":"https://openalex.org/keywords/inlet","display_name":"Inlet","score":0.4858981966972351},{"id":"https://openalex.org/keywords/computer-cooling","display_name":"Computer cooling","score":0.4766412675380707},{"id":"https://openalex.org/keywords/air-cooling","display_name":"Air cooling","score":0.4764845073223114},{"id":"https://openalex.org/keywords/heat-sink","display_name":"Heat sink","score":0.4517095983028412},{"id":"https://openalex.org/keywords/cluster","display_name":"Cluster (spacecraft)","score":0.43634480237960815},{"id":"https://openalex.org/keywords/water-heating","display_name":"Water heating","score":0.42022523283958435},{"id":"https://openalex.org/keywords/process-engineering","display_name":"Process engineering","score":0.38154515624046326},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.24179190397262573},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.2371635138988495},{"id":"https://openalex.org/keywords/heat-exchanger","display_name":"Heat exchanger","score":0.17047765851020813},{"id":"https://openalex.org/keywords/waste-management","display_name":"Waste management","score":0.1612788438796997},{"id":"https://openalex.org/keywords/thermal-management-of-electronic-devices-and-systems","display_name":"Thermal management of electronic devices and systems","score":0.09406208992004395},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.09015634655952454}],"concepts":[{"id":"https://openalex.org/C4638862","wikidata":"https://www.wikidata.org/wiki/Q1501558","display_name":"Chiller","level":2,"score":0.8658488988876343},{"id":"https://openalex.org/C153740404","wikidata":"https://www.wikidata.org/wiki/Q671224","display_name":"Data center","level":2,"score":0.6904810070991516},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5526325702667236},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.5227743983268738},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5035714507102966},{"id":"https://openalex.org/C182254935","wikidata":"https://www.wikidata.org/wiki/Q1722733","display_name":"Water chiller","level":4,"score":0.49377068877220154},{"id":"https://openalex.org/C201289731","wikidata":"https://www.wikidata.org/wiki/Q1172599","display_name":"Inlet","level":2,"score":0.4858981966972351},{"id":"https://openalex.org/C11026015","wikidata":"https://www.wikidata.org/wiki/Q840551","display_name":"Computer cooling","level":3,"score":0.4766412675380707},{"id":"https://openalex.org/C105873366","wikidata":"https://www.wikidata.org/wiki/Q1208873","display_name":"Air cooling","level":2,"score":0.4764845073223114},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.4517095983028412},{"id":"https://openalex.org/C164866538","wikidata":"https://www.wikidata.org/wiki/Q367351","display_name":"Cluster (spacecraft)","level":2,"score":0.43634480237960815},{"id":"https://openalex.org/C2987760187","wikidata":"https://www.wikidata.org/wiki/Q27098513","display_name":"Water heating","level":2,"score":0.42022523283958435},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.38154515624046326},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.24179190397262573},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2371635138988495},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.17047765851020813},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.1612788438796997},{"id":"https://openalex.org/C114834414","wikidata":"https://www.wikidata.org/wiki/Q15477170","display_name":"Thermal management of electronic devices and systems","level":2,"score":0.09406208992004395},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.09015634655952454},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1145/2834800.2834803","is_oa":true,"landing_page_url":"https://doi.org/10.1145/2834800.2834803","pdf_url":"http://dl.acm.org/ft_gateway.cfm?id=2834803&type=pdf","source":null,"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Workshop on Energy Efficient Supercomputing","raw_type":"proceedings-article"},{"id":"pmh:oai:digitalrepository.unm.edu:ece_etds-1035","is_oa":false,"landing_page_url":"https://digitalrepository.unm.edu/ece_etds/36","pdf_url":null,"source":{"id":"https://openalex.org/S4377196368","display_name":"UNM\u2019s Digital Repository (University of New Mexico)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I169521973","host_organization_name":"University of New Mexico","host_organization_lineage":["https://openalex.org/I169521973"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Electrical and Computer Engineering ETDs","raw_type":"text"}],"best_oa_location":{"id":"doi:10.1145/2834800.2834803","is_oa":true,"landing_page_url":"https://doi.org/10.1145/2834800.2834803","pdf_url":"http://dl.acm.org/ft_gateway.cfm?id=2834803&type=pdf","source":null,"license":"public-domain","license_id":"https://openalex.org/licenses/public-domain","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 3rd International Workshop on Energy Efficient Supercomputing","raw_type":"proceedings-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306078","display_name":"U.S. Department of Defense","ror":"https://ror.org/0447fe631"},{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"},{"id":"https://openalex.org/F4320338304","display_name":"Los Alamos National Laboratory","ror":"https://ror.org/01e41cf67"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2194508968.pdf","grobid_xml":"https://content.openalex.org/works/W2194508968.grobid-xml"},"referenced_works_count":6,"referenced_works":["https://openalex.org/W1709486549","https://openalex.org/W1983070234","https://openalex.org/W2041583166","https://openalex.org/W2046188672","https://openalex.org/W2053745362","https://openalex.org/W2143884002"],"related_works":["https://openalex.org/W2373084361","https://openalex.org/W3168899032","https://openalex.org/W2019903672","https://openalex.org/W2765290858","https://openalex.org/W3174617772","https://openalex.org/W2744322886","https://openalex.org/W4240609144","https://openalex.org/W3113570394","https://openalex.org/W2390162002","https://openalex.org/W2375263905"],"abstract_inverted_index":{"With":[0],"water":[1,35,39,136,163,166],"cooling":[2],"becoming":[3],"an":[4],"affordable":[5],"option":[6],"both":[7],"at":[8,11,139,160],"home":[9],"and":[10,37,86,121,158],"scale,":[12],"it":[13],"is":[14,46],"important":[15],"to":[16,48,89,113,135,152,168],"consider":[17],"the":[18,60,80,87,92,115,126,140,153],"possible":[19],"benefits":[20],"over":[21,65,145],"air":[22],"cooling.":[23,40],"There":[24],"are":[25],"several":[26],"methods":[27],"of":[28,44,83,106],"liquid":[29],"cooling,":[30,36],"notables":[31],"include:":[32],"immersion,":[33],"cold":[34],"warm":[38],"The":[41],"total":[42],"cost":[43,75,88,100],"ownership":[45],"difficult":[47],"determine":[49],"with":[50],"these":[51],"options":[52],"as":[53],"each":[54],"has":[55],"a":[56,66,77,99,104,146],"different":[57],"impact":[58],"on":[59],"data":[61,68],"center.":[62],"Considering":[63],"retrofit,":[64],"new":[67],"center,":[69],"introduces":[70],"unforeseen":[71],"variables":[72],"that":[73],"make":[74],"analysis":[76,101],"challenge.":[78],"Besides":[79],"added":[81],"costs":[82,94],"additional":[84],"infrastructure,":[85],"remove":[90],"old,":[91],"upfront":[93],"could":[95],"be":[96,103],"daunting.":[97],"Therefore":[98],"would":[102],"study":[105,110],"its":[107],"own.":[108],"This":[109],"however":[111],"hopes":[112],"reveal":[114],"resulting":[116],"tradeoffs":[117],"in":[118,125],"temperature,":[119],"performance,":[120],"power":[122,156],"usage":[123],"presented":[124],"case":[127],"between":[128],"classical":[129],"airflow":[130],"based":[131],"heat":[132,141],"sink":[133],"mechanisms":[134],"provided":[137],"directly":[138],"sink.":[142],"Having":[143],"control":[144],"discrete":[147],"chiller":[148],"will":[149],"provide":[150],"answers":[151],"CPU":[154],"temperatures,":[155],"usage,":[157],"performance":[159],"various":[161],"inlet":[162],"temperatures.":[164],"To":[165],"or":[167],"air?":[169]},"counts_by_year":[{"year":2017,"cited_by_count":1}],"updated_date":"2026-04-05T17:49:38.594831","created_date":"2025-10-10T00:00:00"}