{"id":"https://openalex.org/W2078008060","doi":"https://doi.org/10.1145/1774674.1774722","title":"Calibration of a computer assisted orthopedic hip surgery phantom","display_name":"Calibration of a computer assisted orthopedic hip surgery phantom","publication_year":2008,"publication_date":"2008-08-19","ids":{"openalex":"https://openalex.org/W2078008060","doi":"https://doi.org/10.1145/1774674.1774722","mag":"2078008060"},"language":"en","primary_location":{"id":"doi:10.1145/1774674.1774722","is_oa":false,"landing_page_url":"https://doi.org/10.1145/1774674.1774722","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 8th Workshop on Performance Metrics for Intelligent Systems","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075219874","display_name":"Daniel Sawyer","orcid":"https://orcid.org/0009-0009-2407-6708"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Daniel Sawyer","raw_affiliation_strings":["NIST, Gaithersburg, MD","NIST., Gaithersburg, MD"],"affiliations":[{"raw_affiliation_string":"NIST, Gaithersburg, MD","institution_ids":[]},{"raw_affiliation_string":"NIST., Gaithersburg, MD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024485311","display_name":"Nick Dagalakis","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Nick Dagalakis","raw_affiliation_strings":["NIST, Gaithersburg, MD","NIST., Gaithersburg, MD"],"affiliations":[{"raw_affiliation_string":"NIST, Gaithersburg, MD","institution_ids":[]},{"raw_affiliation_string":"NIST., Gaithersburg, MD","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049339564","display_name":"Craig M. Shakarji","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Craig Shakarji","raw_affiliation_strings":["NIST, Gaithersburg, MD","NIST., Gaithersburg, MD"],"affiliations":[{"raw_affiliation_string":"NIST, Gaithersburg, MD","institution_ids":[]},{"raw_affiliation_string":"NIST., Gaithersburg, MD","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5101487515","display_name":"Yong Sik Kim","orcid":"https://orcid.org/0000-0003-1731-4762"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Yong Sik Kim","raw_affiliation_strings":["NIST, Gaithersburg, MD","NIST., Gaithersburg, MD"],"affiliations":[{"raw_affiliation_string":"NIST, Gaithersburg, MD","institution_ids":[]},{"raw_affiliation_string":"NIST., Gaithersburg, MD","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5075219874"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.13981412,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"297","last_page":"301"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12386","display_name":"Advanced X-ray and CT Imaging","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12386","display_name":"Advanced X-ray and CT Imaging","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10844","display_name":"Radiation Dose and Imaging","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11930","display_name":"Cardiac, Anesthesia and Surgical Outcomes","score":0.9642000198364258,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.8504103422164917},{"id":"https://openalex.org/keywords/nist","display_name":"NIST","score":0.8200176954269409},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6309627294540405},{"id":"https://openalex.org/keywords/traceability","display_name":"Traceability","score":0.5983690023422241},{"id":"https://openalex.org/keywords/orthopedic-surgery","display_name":"Orthopedic surgery","score":0.5797903537750244},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.5707610249519348},{"id":"https://openalex.org/keywords/medical-physics","display_name":"Medical physics","score":0.4538002908229828},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.4174291789531708},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.3572133779525757},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.19774141907691956},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.1803831160068512},{"id":"https://openalex.org/keywords/radiology","display_name":"Radiology","score":0.17855393886566162},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.17438775300979614}],"concepts":[{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.8504103422164917},{"id":"https://openalex.org/C111219384","wikidata":"https://www.wikidata.org/wiki/Q6954384","display_name":"NIST","level":2,"score":0.8200176954269409},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6309627294540405},{"id":"https://openalex.org/C153876917","wikidata":"https://www.wikidata.org/wiki/Q899704","display_name":"Traceability","level":2,"score":0.5983690023422241},{"id":"https://openalex.org/C68312169","wikidata":"https://www.wikidata.org/wiki/Q216685","display_name":"Orthopedic surgery","level":2,"score":0.5797903537750244},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.5707610249519348},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.4538002908229828},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.4174291789531708},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.3572133779525757},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.19774141907691956},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.1803831160068512},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.17855393886566162},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.17438775300979614},{"id":"https://openalex.org/C115903868","wikidata":"https://www.wikidata.org/wiki/Q80993","display_name":"Software engineering","level":1,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C204321447","wikidata":"https://www.wikidata.org/wiki/Q30642","display_name":"Natural language processing","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/1774674.1774722","is_oa":false,"landing_page_url":"https://doi.org/10.1145/1774674.1774722","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the 8th Workshop on Performance Metrics for Intelligent Systems","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5899999737739563,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W2660441821","https://openalex.org/W2979375368","https://openalex.org/W4205289477"],"related_works":["https://openalex.org/W2158491338","https://openalex.org/W2807901368","https://openalex.org/W2133733652","https://openalex.org/W2072658171","https://openalex.org/W2067160763","https://openalex.org/W2102249898","https://openalex.org/W2046724649","https://openalex.org/W1670618853","https://openalex.org/W4230838604","https://openalex.org/W2463186356"],"abstract_inverted_index":{"Orthopedic":[0,26],"surgeons":[1],"have":[2,55],"identified":[3],"a":[4,57,82,102,114,121,124,217,243],"need":[5],"for":[6,108,123,136,173,198],"calibration":[7,236],"artifacts":[8],"(phantoms)":[9],"to":[10,36,40,64,100,132,169,184,193],"establish":[11],"the":[12,15,66,74,96,138,147,152,156,162,166,170,186,195,199,203,205,235,238],"traceability":[13],"(to":[14],"SI":[16],"unit":[17],"of":[18,20,49,59,69,73,141,146,155,178,202,237],"length)":[19],"measurements":[21],"performed":[22],"with":[23,44,92,216],"Computer":[24],"Assisted":[25],"Surgery":[27],"(CAOS)":[28],"systems.":[29,143],"These":[30],"phantoms":[31,62,79,112],"must":[32],"be":[33,90],"lightweight,":[34],"easy":[35],"transport":[37],"and":[38,51,86,88,106,128,151,165,210,245],"simple":[39],"use.":[41],"In":[42,191],"collaboration":[43],"medical":[45],"professionals,":[46],"National":[47],"Institute":[48],"Standards":[50],"Technology":[52],"(NIST)":[53],"researchers":[54],"developed":[56],"family":[58],"novel":[60],"CAOS":[61,93,142,163,187,228],"designed":[63],"meet":[65],"metrology":[67],"needs":[68],"this":[70,179],"critical":[71,200],"segment":[72],"US":[75],"healthcare":[76],"industry.":[77],"The":[78,111,144,176],"function":[80],"as":[81,120,133],"surrogate":[83],"hip":[84,104,126],"joint":[85,105,127,150,208],"pelvis":[87,107],"can":[89],"measured":[91,160,215],"systems":[94],"using":[95,161,242],"same":[97],"technique":[98],"employed":[99],"measure":[101],"patient's":[103,125],"replacement":[109],"surgery.":[110],"contain":[113],"mechanical":[115,148,206],"ball":[116,149,207],"joint,":[117],"which":[118,223],"functions":[119],"substitute":[122],"small":[129],"holes,":[130,135],"referred":[131],"target":[134,157,211],"receiving":[137],"measuring":[139],"probe":[140],"location":[145,209],"relative":[153],"positions":[154,213],"holes":[158],"are":[159,181,214],"system":[164,188],"results":[167,177],"compared":[168],"known":[171,196],"values":[172,197],"these":[174],"quantities.":[175],"comparison":[180],"then":[182],"used":[183],"verify":[185],"performance":[189],"specifications.":[190],"order":[192],"determine":[194],"dimensions":[201],"phantom,":[204],"hole":[212],"Coordinate":[218],"Measuring":[219],"Machine":[220],"[1]":[221],"(CMM),":[222],"is":[224],"more":[225],"accurate":[226],"than":[227],"Systems.":[229],"This":[230],"paper":[231],"will":[232],"report":[233],"on":[234],"NIST":[239],"prototype":[240],"phantom":[241],"CMM":[244],"simulation":[246],"tools":[247],"at":[248],"NIST.":[249]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}