{"id":"https://openalex.org/W1986591455","doi":"https://doi.org/10.1145/1741906.1742063","title":"Sensitivity analysis of AC coil contactor to voltage sags and enhancement of ride through capability","display_name":"Sensitivity analysis of AC coil contactor to voltage sags and enhancement of ride through capability","publication_year":2010,"publication_date":"2010-02-26","ids":{"openalex":"https://openalex.org/W1986591455","doi":"https://doi.org/10.1145/1741906.1742063","mag":"1986591455"},"language":"en","primary_location":{"id":"doi:10.1145/1741906.1742063","is_oa":false,"landing_page_url":"https://doi.org/10.1145/1741906.1742063","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the International Conference and Workshop on Emerging Trends in Technology","raw_type":"proceedings-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5058930030","display_name":"Sonali M. Akolkar","orcid":"https://orcid.org/0000-0002-6527-4761"},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"S. M. Akolkar","raw_affiliation_strings":["K.K.W.I.E.E. &amp;R-Nashik, Maharashtra (India)"],"affiliations":[{"raw_affiliation_string":"K.K.W.I.E.E. &amp;R-Nashik, Maharashtra (India)","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040686636","display_name":"B. E. Kushare","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"B. E. Kushare","raw_affiliation_strings":["K.K.W.I.E.E. &amp;R-Nashik, Maharashtra (India)"],"affiliations":[{"raw_affiliation_string":"K.K.W.I.E.E. &amp;R-Nashik, Maharashtra (India)","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5058930030"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.2886,"has_fulltext":false,"cited_by_count":2,"citation_normalized_percentile":{"value":0.60538467,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":null,"issue":null,"first_page":"684","last_page":"685"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9915000200271606,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/contactor","display_name":"Contactor","score":0.9889938831329346},{"id":"https://openalex.org/keywords/voltage-sag","display_name":"Voltage sag","score":0.8185311555862427},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.7698627710342407},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.6263212561607361},{"id":"https://openalex.org/keywords/matlab","display_name":"MATLAB","score":0.5346353054046631},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.5101373791694641},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.5007951259613037},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4535676836967468},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4121599495410919},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4093388617038727},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.38207995891571045},{"id":"https://openalex.org/keywords/power-quality","display_name":"Power quality","score":0.3351421356201172},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.23388522863388062},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.0654321014881134}],"concepts":[{"id":"https://openalex.org/C78592999","wikidata":"https://www.wikidata.org/wiki/Q338763","display_name":"Contactor","level":3,"score":0.9889938831329346},{"id":"https://openalex.org/C2781134633","wikidata":"https://www.wikidata.org/wiki/Q14945479","display_name":"Voltage sag","level":4,"score":0.8185311555862427},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.7698627710342407},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.6263212561607361},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.5346353054046631},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5101373791694641},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.5007951259613037},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4535676836967468},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4121599495410919},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4093388617038727},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.38207995891571045},{"id":"https://openalex.org/C2779665505","wikidata":"https://www.wikidata.org/wiki/Q1780079","display_name":"Power quality","level":3,"score":0.3351421356201172},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.23388522863388062},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0654321014881134},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1145/1741906.1742063","is_oa":false,"landing_page_url":"https://doi.org/10.1145/1741906.1742063","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Proceedings of the International Conference and Workshop on Emerging Trends in Technology","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.46000000834465027,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1553032612","https://openalex.org/W2069181855","https://openalex.org/W2101935406","https://openalex.org/W2115120755","https://openalex.org/W2136036965","https://openalex.org/W2546986212","https://openalex.org/W4233743905"],"related_works":["https://openalex.org/W2101993363","https://openalex.org/W2115120755","https://openalex.org/W2053613294","https://openalex.org/W2036394434","https://openalex.org/W2096082143","https://openalex.org/W2092148276","https://openalex.org/W4211041448","https://openalex.org/W2546986212","https://openalex.org/W2013538060","https://openalex.org/W2000295027"],"abstract_inverted_index":{"Voltage":[0],"sags":[1,47],"are":[2,120],"among":[3],"the":[4,33,50,65,71,90],"most":[5],"important":[6],"power":[7],"quality":[8],"events":[9],"due":[10],"to":[11,41,64,70,132,136],"their":[12],"economic":[13],"effect":[14],"on":[15,99,110],"all":[16],"types":[17],"of":[18,39,45],"customers,":[19],"especially":[20],"industrial":[21],"users.":[22],"The":[23],"normal":[24],"device":[25],"used":[26],"for":[27],"motor":[28],"connections":[29],"and":[30,35,73,108],"disconnections":[31],"is":[32,38,59,129],"contactor,":[34],"thus":[36],"it":[37],"importance":[40],"know":[42],"what":[43],"type":[44],"voltage":[46,80,137],"will":[48],"open":[49,78],"AC":[51],"coil":[52,101],"contactor":[53,66,102,134],"or":[54],"engage":[55],"it.":[56],"This":[57,87],"information":[58],"very":[60],"valuable":[61],"not":[62],"only":[63],"user":[67],"but":[68],"also":[69,121,130],"designer":[72],"manufacturer.":[74],"Normal":[75],"contactors":[76],"would":[77],"when":[79],"sag":[81,105],"exists":[82],"in":[83],"its":[84],"supply":[85],"system.":[86],"paper":[88],"shows":[89],"results":[91,114],"obtained":[92],"from":[93],"thorough":[94],"laboratory":[95],"testing":[96],"carried":[97],"out":[98],"ac":[100],"considering":[103],"various":[104],"magnitudes":[106],"durations":[107],"point":[109],"wave":[111],"values.":[112],"Simulation":[113],"with":[115],"MATLAB":[116],"7.1":[117],"Simulator":[118],"version":[119],"presented.":[122],"A":[123],"cost":[124],"effective":[125],"ride":[126],"through":[127],"solution":[128],"discussed":[131],"improve":[133],"immunity":[135],"sags.":[138]},"counts_by_year":[{"year":2014,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
