{"id":"https://openalex.org/W2109326806","doi":"https://doi.org/10.1142/s0218126615500255","title":"Soft Computing Techniques for Static Series Voltage Regulator of Self Excited Induction Generator","display_name":"Soft Computing Techniques for Static Series Voltage Regulator of Self Excited Induction Generator","publication_year":2014,"publication_date":"2014-11-13","ids":{"openalex":"https://openalex.org/W2109326806","doi":"https://doi.org/10.1142/s0218126615500255","mag":"2109326806"},"language":"en","primary_location":{"id":"doi:10.1142/s0218126615500255","is_oa":false,"landing_page_url":"https://doi.org/10.1142/s0218126615500255","pdf_url":null,"source":{"id":"https://openalex.org/S167602672","display_name":"Journal of Circuits Systems and Computers","issn_l":"0218-1266","issn":["0218-1266","1793-6454"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319815","host_organization_name":"World Scientific","host_organization_lineage":["https://openalex.org/P4310319815"],"host_organization_lineage_names":["World Scientific"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Circuits, Systems and Computers","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5110426308","display_name":"Sachin Tiwari","orcid":null},"institutions":[{"id":"https://openalex.org/I91277730","display_name":"Maulana Azad National Institute of Technology","ror":"https://ror.org/026vtd268","country_code":"IN","type":"education","lineage":["https://openalex.org/I91277730"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sachin Tiwari","raw_affiliation_strings":["Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","institution_ids":["https://openalex.org/I91277730"]},{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India","institution_ids":["https://openalex.org/I91277730"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101674107","display_name":"Sushma Gupta","orcid":"https://orcid.org/0000-0002-5382-4383"},"institutions":[{"id":"https://openalex.org/I91277730","display_name":"Maulana Azad National Institute of Technology","ror":"https://ror.org/026vtd268","country_code":"IN","type":"education","lineage":["https://openalex.org/I91277730"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sushma Gupta","raw_affiliation_strings":["Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","institution_ids":["https://openalex.org/I91277730"]},{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India","institution_ids":["https://openalex.org/I91277730"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090001638","display_name":"Shailendra Jain","orcid":"https://orcid.org/0000-0002-3391-1711"},"institutions":[{"id":"https://openalex.org/I91277730","display_name":"Maulana Azad National Institute of Technology","ror":"https://ror.org/026vtd268","country_code":"IN","type":"education","lineage":["https://openalex.org/I91277730"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Shailendra Jain","raw_affiliation_strings":["Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal 462051, India","institution_ids":["https://openalex.org/I91277730"]},{"raw_affiliation_string":"Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal - 462051, India","institution_ids":["https://openalex.org/I91277730"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5067751216","display_name":"Bhim Singh","orcid":"https://orcid.org/0000-0003-4759-7484"},"institutions":[{"id":"https://openalex.org/I68891433","display_name":"Indian Institute of Technology Delhi","ror":"https://ror.org/049tgcd06","country_code":"IN","type":"education","lineage":["https://openalex.org/I68891433"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Bhim Singh","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology, New Delhi 110016, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology, New Delhi 110016, India","institution_ids":["https://openalex.org/I68891433"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4144,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.69079397,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"24","issue":"02","first_page":"1550025","last_page":"1550025"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9969000220298767,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11052","display_name":"Energy Load and Power Forecasting","score":0.9902999997138977,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/prime-mover","display_name":"Prime mover","score":0.875883936882019},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.7098764181137085},{"id":"https://openalex.org/keywords/voltage-regulator","display_name":"Voltage regulator","score":0.6836117506027222},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.5995439887046814},{"id":"https://openalex.org/keywords/voltage-source","display_name":"Voltage source","score":0.5696698427200317},{"id":"https://openalex.org/keywords/voltage-regulation","display_name":"Voltage regulation","score":0.5211572647094727},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.48219218850135803},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.47099393606185913},{"id":"https://openalex.org/keywords/controller","display_name":"Controller (irrigation)","score":0.4517658054828644},{"id":"https://openalex.org/keywords/voltage-controller","display_name":"Voltage controller","score":0.45108187198638916},{"id":"https://openalex.org/keywords/voltage-droop","display_name":"Voltage droop","score":0.331770658493042},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.33048680424690247},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.2834146022796631}],"concepts":[{"id":"https://openalex.org/C153875185","wikidata":"https://www.wikidata.org/wiki/Q3304552","display_name":"Prime mover","level":2,"score":0.875883936882019},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7098764181137085},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.6836117506027222},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.5995439887046814},{"id":"https://openalex.org/C144655898","wikidata":"https://www.wikidata.org/wiki/Q1161128","display_name":"Voltage source","level":3,"score":0.5696698427200317},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.5211572647094727},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.48219218850135803},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47099393606185913},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.4517658054828644},{"id":"https://openalex.org/C156120966","wikidata":"https://www.wikidata.org/wiki/Q7940742","display_name":"Voltage controller","level":5,"score":0.45108187198638916},{"id":"https://openalex.org/C40760162","wikidata":"https://www.wikidata.org/wiki/Q10920295","display_name":"Voltage droop","level":4,"score":0.331770658493042},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33048680424690247},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2834146022796631},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C6557445","wikidata":"https://www.wikidata.org/wiki/Q173113","display_name":"Agronomy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1142/s0218126615500255","is_oa":false,"landing_page_url":"https://doi.org/10.1142/s0218126615500255","pdf_url":null,"source":{"id":"https://openalex.org/S167602672","display_name":"Journal of Circuits Systems and Computers","issn_l":"0218-1266","issn":["0218-1266","1793-6454"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319815","host_organization_name":"World Scientific","host_organization_lineage":["https://openalex.org/P4310319815"],"host_organization_lineage_names":["World Scientific"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Circuits, Systems and Computers","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7900000214576721,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W1979938869","https://openalex.org/W2022401565","https://openalex.org/W2042028063","https://openalex.org/W2074356785","https://openalex.org/W2087779231","https://openalex.org/W2098593791","https://openalex.org/W2102273578","https://openalex.org/W2108339170","https://openalex.org/W2109475766","https://openalex.org/W2128959896","https://openalex.org/W2139807071","https://openalex.org/W2146283708","https://openalex.org/W2161094482","https://openalex.org/W2162253117","https://openalex.org/W2163420770","https://openalex.org/W2548843774"],"related_works":["https://openalex.org/W262103729","https://openalex.org/W2109326806","https://openalex.org/W2539895754","https://openalex.org/W4281564567","https://openalex.org/W2053881165","https://openalex.org/W2546778901","https://openalex.org/W1568330516","https://openalex.org/W2164639980","https://openalex.org/W2214626429","https://openalex.org/W2378951439"],"abstract_inverted_index":{"This":[0],"paper":[1],"deal":[2],"with":[3,80,105,120,142],"soft":[4],"computing":[5],"techniques":[6],"such":[7,48],"as":[8,49],"artificial":[9],"neural":[10],"network":[11],"(ANN),":[12],"fuzzy":[13,144],"logic":[14],"controller":[15],"(FLC)":[16],"and":[17,40,52,77,86,123,128,145,148],"proportional-integral":[18],"(PI)-based":[19],"static":[20],"series":[21,68],"voltage":[22,62,69,79,100,121],"regulator":[23,122],"(SSVR)":[24],"for":[25],"constant":[26,44,75],"speed":[27,45],"prime":[28,46],"mover":[29,47],"driven":[30,54],"self":[31,106],"excited":[32],"induction":[33],"generator":[34],"(SEIG)":[35],"feeding":[36],"three":[37],"phases":[38],"linear":[39],"nonlinear":[41],"loads.":[42],"The":[43,64,89,110],"biogas,":[50],"biomass":[51],"gas-turbine":[53],"standalone":[55],"generating":[56],"system":[57,72,141],"has":[58],"problem":[59],"of":[60,84,138],"poor":[61],"regulation.":[63],"SSVR":[65,90,147],"is":[66,91],"injects":[67],"in":[70,130],"to":[71,73],"maintain":[74],"source":[76,85,102],"load":[78,87],"power":[81],"quality":[82],"improvement":[83],"current.":[88],"modeled":[92,127],"using":[93],"insulated":[94],"gate":[95],"bipolar":[96],"junction":[97],"transistor":[98],"(IGBT)-based":[99],"controlled-voltage":[101],"converter":[103],"(VC-VSC)":[104],"supported":[107],"DC":[108],"bus.":[109],"A":[111],"7.5":[112],"kW,":[113],"415":[114],"V,":[115],"50":[116],"Hz":[117],"asynchronous":[118],"machine":[119],"loads":[124],"are":[125,135],"designed,":[126],"simulated":[129],"MATLAB":[131],"environment.":[132],"Simulated":[133],"results":[134],"presented":[136],"capability":[137],"an":[139],"SEIG":[140],"ANN,":[143],"PI-based":[146],"their":[149],"comparison.":[150]},"counts_by_year":[{"year":2022,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-05-21T06:26:12.895304","created_date":"2025-10-10T00:00:00"}
