{"id":"https://openalex.org/W2657416937","doi":"https://doi.org/10.1109/tr.2017.2710260","title":"Estimation of Remaining Useful Lifetime of Piezoelectric Transducers Based on Self-Sensing","display_name":"Estimation of Remaining Useful Lifetime of Piezoelectric Transducers Based on Self-Sensing","publication_year":2017,"publication_date":"2017-06-19","ids":{"openalex":"https://openalex.org/W2657416937","doi":"https://doi.org/10.1109/tr.2017.2710260","mag":"2657416937"},"language":"en","primary_location":{"id":"doi:10.1109/tr.2017.2710260","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tr.2017.2710260","pdf_url":null,"source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009055464","display_name":"James Kuria Kimotho","orcid":null},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":true,"raw_author_name":"James Kuria Kimotho","raw_affiliation_strings":["University of Paderborn, Paderborn, Germany"],"affiliations":[{"raw_affiliation_string":"University of Paderborn, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043120396","display_name":"Tobias Hemsel","orcid":"https://orcid.org/0000-0003-4418-9653"},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Tobias Hemsel","raw_affiliation_strings":["University of Paderborn, Paderborn, Germany"],"affiliations":[{"raw_affiliation_string":"University of Paderborn, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5038903138","display_name":"Walter Sextro","orcid":null},"institutions":[{"id":"https://openalex.org/I206945453","display_name":"Paderborn University","ror":"https://ror.org/058kzsd48","country_code":"DE","type":"education","lineage":["https://openalex.org/I206945453"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Walter Sextro","raw_affiliation_strings":["University of Paderborn, Paderborn, Germany"],"affiliations":[{"raw_affiliation_string":"University of Paderborn, Paderborn, Germany","institution_ids":["https://openalex.org/I206945453"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5009055464"],"corresponding_institution_ids":["https://openalex.org/I206945453"],"apc_list":null,"apc_paid":null,"fwci":0.8046,"has_fulltext":false,"cited_by_count":13,"citation_normalized_percentile":{"value":0.73344292,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"66","issue":"3","first_page":"914","last_page":"923"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.994700014591217,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/prognostics","display_name":"Prognostics","score":0.8382670879364014},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.7280700206756592},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.6967046856880188},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6142570972442627},{"id":"https://openalex.org/keywords/piezoelectricity","display_name":"Piezoelectricity","score":0.5097927451133728},{"id":"https://openalex.org/keywords/structural-health-monitoring","display_name":"Structural health monitoring","score":0.49676305055618286},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.412501722574234},{"id":"https://openalex.org/keywords/state-of-health","display_name":"State of health","score":0.4109192490577698},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4012368321418762},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.38740965723991394},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.32630059123039246},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17162176966667175},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.15700680017471313}],"concepts":[{"id":"https://openalex.org/C129364497","wikidata":"https://www.wikidata.org/wiki/Q3042561","display_name":"Prognostics","level":2,"score":0.8382670879364014},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.7280700206756592},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6967046856880188},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6142570972442627},{"id":"https://openalex.org/C100082104","wikidata":"https://www.wikidata.org/wiki/Q183759","display_name":"Piezoelectricity","level":2,"score":0.5097927451133728},{"id":"https://openalex.org/C2776247918","wikidata":"https://www.wikidata.org/wiki/Q1423713","display_name":"Structural health monitoring","level":2,"score":0.49676305055618286},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.412501722574234},{"id":"https://openalex.org/C2777294910","wikidata":"https://www.wikidata.org/wiki/Q4050070","display_name":"State of health","level":4,"score":0.4109192490577698},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4012368321418762},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38740965723991394},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.32630059123039246},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17162176966667175},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.15700680017471313},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tr.2017.2710260","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tr.2017.2710260","pdf_url":null,"source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W14067983","https://openalex.org/W26950639","https://openalex.org/W92879698","https://openalex.org/W591732527","https://openalex.org/W826970879","https://openalex.org/W1556459174","https://openalex.org/W1974763478","https://openalex.org/W2061060631","https://openalex.org/W2063760052","https://openalex.org/W2091171784","https://openalex.org/W2117252423","https://openalex.org/W2130213919","https://openalex.org/W2150967358","https://openalex.org/W2160337655","https://openalex.org/W2162741527","https://openalex.org/W2387660017","https://openalex.org/W2395102788","https://openalex.org/W2751544445","https://openalex.org/W3161789875","https://openalex.org/W6600574561","https://openalex.org/W6601068964","https://openalex.org/W6633355566","https://openalex.org/W6665908082","https://openalex.org/W6710909407","https://openalex.org/W6794981182"],"related_works":["https://openalex.org/W3202873688","https://openalex.org/W4283021103","https://openalex.org/W2012595183","https://openalex.org/W2908973203","https://openalex.org/W2801712269","https://openalex.org/W2130213919","https://openalex.org/W2297255570","https://openalex.org/W2115233498","https://openalex.org/W2045186954","https://openalex.org/W3000986292"],"abstract_inverted_index":{"Piezoelectric":[0],"transducers":[1,13,127],"are":[2,105],"used":[3,52,106,153],"in":[4,18,179],"a":[5,93,102,129],"wide":[6],"range":[7],"of":[8,11,26,29,60,79,101,125,135,144,157,162],"applications.":[9],"Reliability":[10],"these":[12],"is":[14,64,112,151,165,177],"an":[15],"important":[16],"aspect":[17],"their":[19],"application.":[20],"Prognostics,":[21],"which":[22],"involve":[23],"continuous":[24],"monitoring":[25,110],"the":[27,38,45,55,61,68,77,80,108,123,126,133,136,141,163,171,175,181],"health":[28,40,69,130,142,149,182],"technical":[30],"systems":[31],"and":[32,42,58,71,132,170,184],"using":[33,167],"this":[34,91],"information":[35],"to":[36,53,74,83,121,139,154],"estimate":[37,140,155],"current":[39,148],"state":[41,70],"consequently":[43],"predict":[44],"remaining":[46],"useful":[47],"lifetime":[48],"(RUL),":[49],"can":[50],"be":[51],"increase":[54],"reliability,":[56],"safety,":[57],"availability":[59],"transducers.":[62,146],"This":[63],"achieved":[65],"by":[66],"utilizing":[67,96],"RUL":[72,156],"predictions":[73],"adaptively":[75],"control":[76],"usage":[78],"components":[81],"or":[82],"schedule":[84],"appropriate":[85],"maintenance":[86],"without":[87],"interrupting":[88],"operation.":[89],"In":[90],"work,":[92],"prognostic":[94],"approach":[95,115,164],"self-sensing,":[97],"where":[98],"electric":[99],"signals":[100],"piezoelectric":[103,168],"transducer":[104],"as":[107],"condition":[109],"data,":[111],"proposed.":[113],"The":[114,147,160],"involves":[116],"training":[117],"machine":[118],"learning":[119],"algorithms":[120],"model":[122,138],"degradation":[124],"through":[128],"index":[131,143,150,183],"use":[134],"learned":[137],"similar":[145],"then":[152],"test":[158],"components.":[159],"feasibility":[161],"demonstrated":[166],"bimorphs":[169],"results":[172],"show":[173],"that":[174],"method":[176],"accurate":[178],"predicting":[180],"RUL.":[185]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
