{"id":"https://openalex.org/W2331828378","doi":"https://doi.org/10.1109/tim.2015.2508258","title":"Low-Cost Instrument for Whispering Gallery Mode Thermometry up to 19 GHz","display_name":"Low-Cost Instrument for Whispering Gallery Mode Thermometry up to 19 GHz","publication_year":2015,"publication_date":"2015-12-30","ids":{"openalex":"https://openalex.org/W2331828378","doi":"https://doi.org/10.1109/tim.2015.2508258","mag":"2331828378"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2015.2508258","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2508258","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://hal.science/hal-05213086","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5061758910","display_name":"Simone Corbellini","orcid":"https://orcid.org/0000-0002-8746-4398"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Politecnico di Torino","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Simone Corbellini","raw_affiliation_strings":["Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5071495427","display_name":"Chiara Ramella","orcid":"https://orcid.org/0000-0003-0634-1474"},"institutions":[{"id":"https://openalex.org/I116067653","display_name":"University of Rome Tor Vergata","ror":"https://ror.org/02p77k626","country_code":"IT","type":"education","lineage":["https://openalex.org/I116067653"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Chiara Ramella","raw_affiliation_strings":["Department of Electronic Engineering, University of Rome Tor Vergata, Rome, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronic Engineering, University of Rome Tor Vergata, Rome, Italy","institution_ids":["https://openalex.org/I116067653"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5057871071","display_name":"Marco Pirola","orcid":"https://orcid.org/0000-0002-5759-9697"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Politecnico di Torino","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Marco Pirola","raw_affiliation_strings":["Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046057088","display_name":"Vito Fernicola","orcid":"https://orcid.org/0000-0003-3495-3574"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Vito C. Fernicola","raw_affiliation_strings":["Department of Innovation and Metrology Services, Istituto Nazionale di Ricerca Metrologica, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Innovation and Metrology Services, Istituto Nazionale di Ricerca Metrologica, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042105887","display_name":"Andr\u00e9a Cappella","orcid":"https://orcid.org/0000-0003-1146-0187"},"institutions":[{"id":"https://openalex.org/I124158823","display_name":"Conservatoire National des Arts et M\u00e9tiers","ror":"https://ror.org/0175hh227","country_code":"FR","type":"education","lineage":["https://openalex.org/I124158823","https://openalex.org/I4210134562"]},{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Andrea Cappella","raw_affiliation_strings":["Laboratoire Commun de M\u00e9trologie, Laboratoire National d\u2019Essais, Conservatoire National des Arts et M\u00e9tiers, Saint-Denis, France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Laboratoire Commun de M\u00e9trologie, Laboratoire National d\u2019Essais, Conservatoire National des Arts et M\u00e9tiers, Saint-Denis, France","institution_ids":["https://openalex.org/I4210107682","https://openalex.org/I124158823"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6025,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.74419801,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"65","issue":"5","first_page":"1206","last_page":"1214"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10299","display_name":"Photonic and Optical Devices","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10299","display_name":"Photonic and Optical Devices","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11160","display_name":"Acoustic Wave Resonator Technologies","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11449","display_name":"Mechanical and Optical Resonators","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/whispering-gallery-wave","display_name":"Whispering-gallery wave","score":0.8922277092933655},{"id":"https://openalex.org/keywords/whispering-gallery","display_name":"Whispering gallery","score":0.774011492729187},{"id":"https://openalex.org/keywords/resonator","display_name":"Resonator","score":0.7471824288368225},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.62574702501297},{"id":"https://openalex.org/keywords/thermometer","display_name":"Thermometer","score":0.5502663254737854},{"id":"https://openalex.org/keywords/microwave","display_name":"Microwave","score":0.5391218662261963},{"id":"https://openalex.org/keywords/resonance","display_name":"Resonance (particle physics)","score":0.5141425728797913},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.48597773909568787},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.46438372135162354},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.4314321279525757},{"id":"https://openalex.org/keywords/liquid-helium","display_name":"Liquid helium","score":0.4273379147052765},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.39609670639038086},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.36750102043151855},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.33506691455841064},{"id":"https://openalex.org/keywords/helium","display_name":"Helium","score":0.31387823820114136},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.27529996633529663},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.13595658540725708}],"concepts":[{"id":"https://openalex.org/C77255779","wikidata":"https://www.wikidata.org/wiki/Q7993947","display_name":"Whispering-gallery wave","level":3,"score":0.8922277092933655},{"id":"https://openalex.org/C123342330","wikidata":"https://www.wikidata.org/wiki/Q1434964","display_name":"Whispering gallery","level":4,"score":0.774011492729187},{"id":"https://openalex.org/C97126364","wikidata":"https://www.wikidata.org/wiki/Q349669","display_name":"Resonator","level":2,"score":0.7471824288368225},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.62574702501297},{"id":"https://openalex.org/C2777155165","wikidata":"https://www.wikidata.org/wiki/Q646","display_name":"Thermometer","level":2,"score":0.5502663254737854},{"id":"https://openalex.org/C44838205","wikidata":"https://www.wikidata.org/wiki/Q127995","display_name":"Microwave","level":2,"score":0.5391218662261963},{"id":"https://openalex.org/C139210041","wikidata":"https://www.wikidata.org/wiki/Q2145840","display_name":"Resonance (particle physics)","level":2,"score":0.5141425728797913},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.48597773909568787},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.46438372135162354},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4314321279525757},{"id":"https://openalex.org/C1855228","wikidata":"https://www.wikidata.org/wiki/Q1203476","display_name":"Liquid helium","level":3,"score":0.4273379147052765},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.39609670639038086},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.36750102043151855},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.33506691455841064},{"id":"https://openalex.org/C546029482","wikidata":"https://www.wikidata.org/wiki/Q560","display_name":"Helium","level":2,"score":0.31387823820114136},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.27529996633529663},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.13595658540725708},{"id":"https://openalex.org/C109214941","wikidata":"https://www.wikidata.org/wiki/Q18334","display_name":"Particle physics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C184779094","wikidata":"https://www.wikidata.org/wiki/Q26383","display_name":"Atomic physics","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tim.2015.2508258","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2508258","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:HAL:hal-05213086v1","is_oa":true,"landing_page_url":"https://hal.science/hal-05213086","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement, 2016, 65 (5), pp.1206-1214. &#x27E8;10.1109/tim.2015.2508258&#x27E9;","raw_type":"Journal articles"},{"id":"pmh:oai:iris.inrim.it:11696/68455","is_oa":true,"landing_page_url":"http://hdl.handle.net/11696/68455","pdf_url":null,"source":{"id":"https://openalex.org/S4306400708","display_name":"CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I27837315","host_organization_name":"University of Michigan","host_organization_lineage":["https://openalex.org/I27837315"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:HAL:hal-05213086v1","is_oa":true,"landing_page_url":"https://hal.science/hal-05213086","pdf_url":null,"source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement, 2016, 65 (5), pp.1206-1214. &#x27E8;10.1109/tim.2015.2508258&#x27E9;","raw_type":"Journal articles"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.4099999964237213}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1600464418","https://openalex.org/W1969608600","https://openalex.org/W1970031752","https://openalex.org/W1971578731","https://openalex.org/W1997918820","https://openalex.org/W2008631448","https://openalex.org/W2016301989","https://openalex.org/W2050087586","https://openalex.org/W2053196580","https://openalex.org/W2057302923","https://openalex.org/W2057663779","https://openalex.org/W2077340901","https://openalex.org/W2080647002","https://openalex.org/W2108814491","https://openalex.org/W2138877368","https://openalex.org/W2148020336","https://openalex.org/W2148138963","https://openalex.org/W6643194762"],"related_works":["https://openalex.org/W3006809570","https://openalex.org/W3202186320","https://openalex.org/W2017053021","https://openalex.org/W1978237153","https://openalex.org/W1990666473","https://openalex.org/W1987403586","https://openalex.org/W4234462136","https://openalex.org/W2023250655","https://openalex.org/W2025493389","https://openalex.org/W2064487123"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"a":[3,46,120],"portable":[4],"low-cost":[5],"system":[6],"for":[7,19,34,73,92,106],"the":[8,35,43,87,99,103,123,126,132,145,148,165,175],"accurate":[9,156],"measurement":[10],"of":[11,37,45,79,98,125,131,147,167],"complex":[12],"resonance":[13,38],"frequencies":[14,39],"up":[15],"to":[16,101,150,163],"19":[17],"GHz":[18,63],"whispering":[20,93,107,127,168],"gallery":[21,94,108,128,169],"mode":[22],"thermometry":[23,109],"is":[24,71,89,110,139],"presented":[25],"and":[26,64,135,159],"validated.":[27],"The":[28,68,96,141],"instrument":[29,100,134,149],"performs":[30],"vectorial":[31],"transmission":[32],"measurements":[33],"determination":[36],"with":[40],"accuracy":[41],"in":[42,49,50,82,155,174],"order":[44],"few":[47],"parts":[48],"10":[51],"<sup":[52],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[53],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">9</sup>":[54],"over":[55],"two":[56],"different":[57,83],"RF/microwave":[58],"bands:":[59],"1)":[60],"800":[61],"MHz-7":[62],"2)":[65],"13-19":[66],"GHz.":[67],"former":[69],"band":[70],"suitable":[72],"quasi-spherical":[74],"resonator":[75,138],"(QSR)-based":[76],"experiments,":[77],"currently":[78],"great":[80],"interest":[81],"metrological":[84],"applications,":[85],"while":[86],"latter":[88],"expressly":[90],"supported":[91],"thermometry.":[95],"capability":[97,162],"meet":[102],"performance":[104],"required":[105],"first":[111],"verified":[112],"using":[113],"an":[114,136],"extremely":[115],"stable":[116],"setup":[117],"based":[118],"on":[119],"QSR.":[121],"Afterward,":[122],"calibration":[124],"thermometer":[129],"composed":[130],"developed":[133],"existing":[137],"performed.":[140],"obtained":[142],"results":[143],"prove":[144],"suitability":[146],"replace":[151],"vector":[152],"network":[153],"analyzers":[154],"resonance-based":[157],"experiments":[158],"also":[160],"its":[161],"enable":[164],"use":[166],"thermometers":[170],"as":[171],"transfer":[172],"standards":[173],"industrial":[176],"field.":[177]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
